HD2402 is a portable photo-radiometer data logger for the measurement of noncoherent optical radiation in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
The instrument consists of a series of sensors to cover different portions of the spectrum and a small laser which is used to indicate the analyzed source.
The various sensors operate in the following spectral fields:
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.
The HD2402 can be powered either by connecting it to a PC, receiving power directly from the USB port of your PC, or via an external power supply with USB output (code SWD05). The CP24 connection cable is fitted with a M12 connector
on the instrument side and an USB type A connector on the PC side or to the power supply SWD05.
Using the software DeltaLog13 from version 1.0.1.0 and a PC, the HD2402 can be configured (calendar, date, time, start and duration of logging), and you can download and analyze the stored data or acquire the real-time data. Once configured, the data logger can be disconnected from the PC and connected to its power supply for capturing and storing data according to the programmed settings.
Complete with: DeltaLog13 software (version 1.0.1.0) to download, monitor and process the data on personal computer,
hardware key CH20 to enable the software, CP24 cable, power supply SWD05, manual, carrying case.
Alte produse SENSECA
|
TERMOMETRU DIGITAL PORTABIL SENZOR PT100 -200°C +650°C DELTA OHM HD2307.0
• Thermometer, Pt100 sensor with one input for probes equipped with SICRAM module, |
|
CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR CU MASURA REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE TDS DELTA OHM HD2206.2
• Bench-top conductivity meter-Thermometer with back-lighted display, |
|
CALIBRATOR ACUSTIC NIVEL SUNET PENTRU CALIBRARE MICROFON SI STATII ACUSTICE DELTA OHM HD2020
• HD 2020 sound level calibrator |
|
PIRGEOMETRU METEO MASURA RADIATIE INFRAROSU DELTA OHM LP PIRG01
• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR). |
|
PIRANOMETRU CU FOTODIODA SILICONICA MASURA RADIATIE SOLARA GLOBALA PANOURI FOTOVOLTAICE DELTA OHM LP SILICON-PYRA04
• LP Silicon-PYRA 04. pyranometer |
|
LUXMETRU FOTO-RADIOMETRU MASURA ILUMINANTA, PAR, IRADIANTA SOLARA DELTA OHM HD2102.1 HD2102.2
• Device for measuring illuminance, luminance, PAR, irradiance. |
|
PIRANOMETRU CLASA A 2A IN CONFORMITATE CU STANDARDUL ISO9060 DELTA OHM LP PYRA08
• Second class pyranometer according to ISO 9060, |
|
PH-METRU-CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR DELTA OHM HD3456.2
• Bench-top pHmeter-Conductivity meter-Thermometer |
|
TESTER MONITORIZARE SI ANALIZA CALITATE AER INTERIOR, MONOXID, BIOXID DE CARBON DELTA OHM HD37AB1347
• Datalogger for indoor air quality analysis (IAQ) |
|
TESTER OXIGEN DIZOLVAT SI TERMOMETRU CU DATALOGGING DELTA OHM HD2109.1 HD2109.2
• Oxygen meter-Thermometer measures dissolved oxygen, saturation index and temperature. |