Piranometru clasa a 2a in conformitate cu standardul ISO9060 Delta Ohm LP PYRA08

Cod: Delta Ohm LP PYRA08


 

Brosura produs PDF, 0.84 Mb

Descriere

Second class pyranometer according to ISO 9060,
fast response sensor complete with calibration report,
possibility to replace the exhausted silica-gel.
Different configurations available.
Male M12 connector.
On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.
 

Alte produse SENSECA

DATALOGGER FOTO-RADIOMETRU LUMINA SOLARA, TEMPERATURA DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

DATALOGGER MULTIFUNCTIONAL 3 CANALE INREGISTRARE PARAMETRI CALITATE MEDIU AER DELTA OHM DO9847

• Multifunctional handheld board instrument and datalogger
• RH, temperature, pressure, airspeed, light, voltage, current
• 128x64 pixel (56x38 mm) graphic display and three independent inputs
• Functions: watch, hold, max., min., average, record, immediate or deferred start record logging, difference between the two inputs, relative measures
• Storage capacity: 32.000 readings per input.
• RS232C serial output: from 300 up to 115.200 baud rate.

 

PH-METRU TERMOMETRU CU DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

TESTER MONITORIZARE SI ANALIZA CALITATE AER INTERIOR, MONOXID, BIOXID DE CARBON DELTA OHM HD37AB1347

• Datalogger for indoor air quality analysis (IAQ)
• measures: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide)
• Memory capacity of 67,600 records for each of the two inputs.
• Logging interval from 15 seconds to 1 hour.

 

TESTER MULTIPARAMETRU PH-METRU-CONDUCTIVIMETRU-TERMOMETRU DELTA OHM HD2156.1 HD2156.2

• pHmeter-Conductivity-Thermometer measures pH, mV, conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger, stores the maximum, minimum, average value and can store up to 20,000 sets of three measurements.
• USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

ANALIZOR AUDIO SUNET CLASA I CU DATALOGGER, ANALIZA SPECTRU ACUSTIC OCTAVA 3A, STATISTICI DELTA OHM HD2110L

• precision integrating portable sound level meter
• data logging function
• performing both spectrum and statistical analysis
• high-performance analysis of acoustic phenomena
• Class 1 sound level meter according to IEC 61672-1, 2002 , IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz
• Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s

 

ANEMOMETRU-TERMOMETRU DIGITAL DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

SURSA SUNET CU GENERARE SEMNAL AUDIO PENTRU CALIBRARI NIVEL ACUSTIC CLASA I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

LUXMETRU FOTO-RADIOMETRU MASURA ILUMINANTA, PAR, IRADIANTA SOLARA DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree