Piranometru clasa a 2a in conformitate cu standardul ISO9060 Delta Ohm LP PYRA08

Cod: Delta Ohm LP PYRA08


 

Brosura produs PDF, 0.84 Mb

Descriere

Second class pyranometer according to ISO 9060,
fast response sensor complete with calibration report,
possibility to replace the exhausted silica-gel.
Different configurations available.
Male M12 connector.
On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.
 

Alte produse SENSECA

TERMOMETRU DIGITAL PORTABIL SENZOR PT100 -200°C +650°C DELTA OHM HD2307.0

• Thermometer, Pt100 sensor with one input for probes equipped with SICRAM module,
• measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• Functions: REL, HOLD and auto-power-off which can be disabled
• IP 67 protection degree

 

ANEMOMETRU ULTRASONIC MASURA VITEZA SI DIRECTIE VANT TREI AXE DELTA OHM HD2003 HD2003.1

• Determination of the anemometric quantities represented in diverse measurement units:
• wind speed and direction,
• U-V-W Cartesian components of speed,
• sound speed,
• sonic temperature
• 5 analogue voltage or current outputs, with different measuring ranges.
• RS232 and Multidrop RS485 Serial Communication interfaces.

 

ANEMOMETRU ULTRASONIC MASURA VITEZA SI DIRECTIE VANT DOUA AXE DELTA OHM HD52.3

• 2 axes ultrasonic Anemometers series HD 52.3D
• Wind speed and direction, U-V Cartesian components of wind speed,
• Relative Humidity and Temperature (option, code "17"),
• Diffuse Solar Radiation (option, code "P"),
• Barometric pressure (option, code "4").

 

DATALOGGER ANALIZA MONITORIZARE CALITATE MEDIU AER, MONOXID, BIOXID CARBON DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

ANEMOMETRU-TERMOMETRU DIGITAL DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

DATALOGGER HVACR VITEZA SI DEBIT AER, PRESIUNE, TEMPERATURA, UMIDITATE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


CONDUCTIVIMETRU-TERMOMETRU MASURA CONDUCTIVITATE, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, SALINITATE, TEMPERATURA DELTA OHM HD2306.0

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

PH-METRU TERMOMETRU CU DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

TURBIDIMETRU PORTABIL DE LABORATOR TESTARE LICHIDE PROCES, APA POTABILA, APE UZATE DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11