FLUKE TiS10 Camera de termoviziune 80x60

Cod: FLUKE TiS10


 

Brosura produs PDF, 1.63 Mb

Descriere

Modele:
Fluke TiS10 80x60 pixels
Fluke TiS20 120x90 pixels
Fluke TiS40 160x120 pixels
Fluke TiS45 160x120 pixels
Fluke TiS50 220x165 pixels
Fluke TiS55 220x165 pixels
Fluke TiS60 260x195 pixels
Fluke TiS65 260x195 pixels
 
Camera cu infrarosu Fluke TiS10

Camera cu infrarosu din nivelul de baza al gamei, usor de folosit, cu rezolutie 80x60 - ideala pentru scanari si inspectii rapide.

 

 

  • Focalizare fixa pentru simplitate focalizare si declansare
  • Imagini de calitate accesibile ca pret - rezolutie de 80 x 60 (4.800 pixeli)
  • D:S de 128:1
  • LCD de 3,5 inch, 320 x 240
  • Camera digitala de 5 megapixeli
  • Sistem cu baterie inteligenta - baterie litiu-ion inteligenta cu afisaj LED cu cinci segmente pentru indicarea nivelului de încarcare
  • Trimiteti e-mailuri si partajati imagini în timp real cu usurinta, utilizând Fluke Connect®
  • Stocheaza mii de imagini - memorie interna de 4 GB si card micro SD optional de 4 GB
 

Accesorii standard

Inclus

Camerele de termoviziune sunt expediate cu

un adaptor de alimentare c.a. universal,

baterie inteligenta Li-ion (TiS65/60 include câte 2-celelalte modele 1 fiecare),

cablu USB,

card Micro SD (TiS65/60, TiS55, TiS45),

geanta de transport rigida (TiS65/60, TiS55/50, TiS45/40), geanta de transport moale,

curea de mâna reglabila (TiS65/60, TiS55/50, TiS45/40),

documentatie si fisa tehnica de siguranta.

Software  disponibil pentru descarcare de la www.fluke.com/smartviewdownload. Modelele TiS65/60 includ un încarcator dublu pentru acumulatori

 

 

Optiuni recomandate

Accesorii optionale

FLK-BLUETOOTH - casca Bluetooth

FLK-TI-TRIPOD3 - accesoriu pentru montare pe trepied

BOOK-ITP - cartea Introducere în principiile termografiei

FLK-TI-SBP3 - baterie inteligenta suplimentara

FLK-TI-SBC3B - încarcator baterie inteligenta

TI-CAR CHARGER - încarcator auto

 

Alte produse FLUKE

CLESTE AMPERMETRIC DE CURENT 400A FLUKE 322

• Measures AC current to 400 A with 0.1 A resolution
• Measures AC current to 40 A with 0.01 A resolution, precise low current measurements
• Measures AC volts to 600 V, with 0.1 V resolution to 400.0 V
• Measures DC volts to 600 V, with 0.1 resolution to 400.0 V
• Resistance measurement to 400 O
• Precise measurements with 1.8% basic accuracy

 

FLUKE TIS45 CAMERA DE TERMOVIZIUNE 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

TESTER TENSIUNE SI CONTINUITATE FLUKE T140

• Resistance measurement
• Backlight
• LED Bargraph
• Display: 3½ digit LCD
• Voltage test
• Optical and acoustical continuity test

 

CALIBRATOR MULTIFUNCTIONAL APARATE DE MASURA FLUKE 5522A

• Handheld and bench meters (analog and digital) up to 6 ½ digits
• Current clamps and clamp meters, Thermocouples and RTDs
• Process calibrators, Data loggers
• Strip and chart recorders, Watt meters
• Power harmonics analyzers, Panel meters
• Graphical multimeters, Power quality analyzers (with option)

 

ANEMOMETRU MULTIFUNCTIONAL FLUKE 922

• Air Pressure
• Air Velocity
• Air Flow (Volume)
• Temperature

 

DETECTOR PREZENTA TENSIUNE FLUKE LVD2 VOLT LIGHT

• Dual Sensitivity
• LED light with 100,000 hour life
• Detects from 90 to 600 V AC
• Rated to CAT IV 600 V

 

RLC-METRU 50 HZ..1 MHZ FLUKE 6306

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display

 

FLUKE TIS60 CAMERA DE TERMOVIZIUNE 260X195

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

CALIBRATOR DE PRESIUNE FLUKE 718EX

• ATEX II 1G Ex ia IIC T4 Compliant
• Built-in pressure / vacuum hand pump
• Pressure measurement to 0.05%
• Pressure measurement to 200

 

CALIBRATOR TEMPERATURA SI TERMOCUPLU FLUKE 714

• -200 to 1800ºC Range Measure / simulate thrmocouple
• -10 to 75 mV Range Measure / simulate voltage
• Measure temperature from TC output