Calibrator portabil de bucla Fluke 705

Cod: Fluke 705


 

Brosura produs PDF, 0.53 Mb

Descriere

  • 0 to 28 V DC Voltage measure
  • 0 to 24 mA Current measure
  • 0 to 20 mA Current source / simulate
  • A large display and simple, pushbutton interface for ease of use
  • Simultaneous mA and % readout for quick, easy interpretation of readings
  • mA accuracy of 0.02%
  • Push button 25% steps for fast, easy linearity checks
  • "Span Check" for fast confirmation of zero and span
  • Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests
  • 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
  • Single 9V battery that is easily changed
  • 0 - 20 mA or 4 - 20 mA default start up modes
  • Safety conformance CSA C22.2 No. 1010.1:1992
 

Accesorii standard

  • AC70A Alligator Clips
  • C10 protective yellow holster with Flex-Stand™
  • Instruction sheet
  • TL75 safety-designed test lead set
  • NIST- traceable calibration report and data
 

Alte produse FLUKE

INDICATOR SUCCESIUNE FAZE FLUKE 9040

• 3 phase indication
• Indication of phase rotation
• Clear LCD display
• No battery required

 

FLUKE 438 II ANALIZOR MOTOARE SI CALITATE ENERGIE ELECTRICA

• Masurati parametrii cheie ai motoarelor cu conectare directa, inclusiv cuplul, turatia, puterea mecanica si randamentul motorului
• Masurati parametrii de putere electrica precum tensiunea, curentul, puterea, puterea aparenta, factorul de putere, distorsiunea armonica si dezechilibrul, pentru identificarea caracteristicilor care afecteaza randamentul motorului
• Identificati problemele de calitate a energiei precum caderile, vârfurile, fenomenele tranzitorii, armonicile si dezechilibrul

 

CALIBRATOR TERMOREZISTENTE FLUKE 712B

• measure and simulate (13) different RTD types and resistance
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

ANALIZOR DE PUTERE DE PRECIZIE FLUKE NORMA 5000

• 3, 4 or 6 power phases
• Bandwidth from dc to 3 MHz / 10 MHz
• FFT analysis, vector diagram, and Digital Oscilloscope
• Voltage, current and power harmonics measured up to the 40th harmonic

 

CLESTE AMPERMETRIC CURENT TRUE-RMS 400A FLUKE 324

• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection
• Temperature and capacitance measurement

 

CALIBRATOR TEMPERATURA SI TERMOREZISTENTE FLUKE 712

• -200 to 800ºC Range Measure / simulate RTD (Pt 100)
• 0 to 3200 O Range Measure / simulate resistance
• 0.1 O, 0.1 ºC Resolution

 

CLESTE MASURARE PRIZA DE PAMANT FLUKE 1630

• resistance range from 0.025 O to 1500 O
• large jaw opening of 35 mm
• ground leakage current, from 0.2 mA to 1000 mA
• ac current measurement range from 0.2 A to 30 A

 

TESTER ELECTRIC 600V TENSIUNE CURENT CONTINUITATE FLUKE T5-600

• 600V model
• Automatically measures V AC, V DC with precise digital resolution
• 100 A AC Current
• Displays resistance to 1000O

 

RLC-METRU 50 HZ..1 MHZ FLUKE 6306

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display

 

DETECTOR DE TENSIUNE FLUKE 2AC VOLTALERT

• Voltage detection from 200 to 1000 V AC
• Category IV - 1000 V overvoltage rated product