Calibrator de presiune Fluke 719

Cod: Fluke 719


 

Brosura produs PDF, 0.54 Mb

Descriere

  • Electric pump for one handed pressure calibration
  • Best in class pressure measurement uncertainty of 0.025%
  • Measure and source mA with best in class 0.015% accuracy
  • Precision pressure adjust vernier for accurate pressure calibration
  • Variable release rate bleed valve for easy pressure adjustment
  • Ideal performance for high accuracy transmitter calibration
  • 30 PSI and 100 PSI pressure ranges
  • Programmable pressure calibrator pump limit
  • eliminates over-pressurization
  • allows the user to program target pressures for pumping
  • Extended pressure measurement range with any of 29 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to test valves and I/Ps
  • Simulate mA signals to troubleshoot 4-20 mA loops
  • Test pressure switches with built in switch test function
  • Power transmitters during test using 24 V loop supply with simultaneous mA measurement
  • Pressure Calibrator includes proven cleanout ports reduce pump failures
 

Accesorii standard

  • Protective Yellow Holster
  • Instructions Sheet (15 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • Hose Kit
  • NIST - Traceable calibration report and data
 

Optiuni recomandate

Fluke 719 30G

Electric Pressure Calibrator, 30 psi, 2 bar

Fluke 719 100G

Electric Pressure Calibrator, 100 psi, 7 bar

 

Alte produse FLUKE

CLESTE MASURARE PRIZA DE PAMANT FLUKE 1630

• resistance range from 0.025 O to 1500 O
• large jaw opening of 35 mm
• ground leakage current, from 0.2 mA to 1000 mA
• ac current measurement range from 0.2 A to 30 A

 

CALIBRATOR MULTIFUNCTIONAL DE PROCES FLUKE 741B

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate

 

TERMOMETRU INFRAROSU FARA CONTACT FLUKE 572

• Backlit display for poorly lit areas
• Last ten temperature readings displayed on bar graph for easy reference
• Enhanced optics (distance to spot ratio up to 60:1) allow measurements of smaller objects from farther away
• Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances (90% energy)
• MIN/MAX measurements calculations instantly computed
• Audible and visible HI temperature alarm for instant recognition

 

FLUKE TIX500 CAMERA DE TERMOVIZIUNE 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

TETER PORTABIL MONOXID DE CARBON CO FLUKE CO-220

• Rugged case and electronics.
• Large LCD displays CO levels from 0 to 1000 ppm.
• Bright back-light allows easy screen viewing under dim lighting conditions.
• Beeper triggers with increasing frequency as CO levels rise.
• MAX Hold function stores and displays the maximum CO level.
• Automatic sensor zeroing and self-test sequence upon start-up.

 

POMPA HIDRAULICA CALIBRARE PRESIUNI FLUKE 700HTP-2

• hand operated hydraulic pressure pump
• designed to generate calibration pressures up to 10,000 psi/690 bar
• Variable size stroke adjustment, allows the user to vary the volume and pressure per stroke
• Integral pressure adjustment vernier knob for fine pressure adjustment
• Directly connection to pressure modules consolidates two separate pieces into one when performing pressure calibration and testing
• Two ¼ inch NPT pressure ports, one for reference (pressure module or gauge), one for UUT
• Improved priming
• Improved stroke limiting mechanism

 

TESTER TENSIUNE SI CONTINUITATE FLUKE T120

• LED Bargraph
• Display: Fluke T120: 3½ digit LCD
• Voltage test
• Optical and acoustical continuity test

 

TESTER TENSIUNE SI CONTINUITATE FLUKE T90/ T110/ T130/ T150

• Voltage AC/DC 12V - 690V
• Continuity 0 - 400 k?
• Frequency 0 / 40 - 400 Hz
• Phase rotation
• Resistance measurement

 

MEGOHMETRU DIGITAL MULTIMETRU IZOLATIE 50/ 1000V FLUKE 1507

• Insulation test range: 0.01 MO to 10 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

 

CALIBRATOR MULTIFUNCTIONAL DE PROCES FLUKE 725

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure