Cleste curent calibrare proces Fluke 772

Cod: Fluke 772


 

Brosura produs PDF, 0.75 Mb

Descriere

  • 0 to 24 mA Current measure / source / simulate
  • Best in class 0.2 % accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without "breaking the loop"
  • Measure mA signals for PLC and control system analog I/O
  • Measure 4 to 20 mA signals with in-circuit measurement
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps
  • mA output linear ramp or 25% step output
  • Automatically change the 4 to 20 mA output for remote testing
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements
 

Accesorii standard

  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet
  • Hanging tool with hook and loop strap
 

Alte produse FLUKE

CALIBRATOR DE PRESIUNE FLUKE 721

• 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor
• 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
• Ideal for gas flow calibration (custody transfer) applications
• Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
• Pt100 RTD input for temperature measurement, (probe optional)
• Measures 4 to 20 mA signals
• Internal 24 V loop power supply can power a transmitter under test
• Measure up to 30 V dc, check 24 V loop power supplies

 

MULTIMETRU DIGITAL DE REFERINTA 8.5 DIGIT FLUKE 8508A

• 8.5 digit
• 2.7 ppm stability

 

FLUKE TIX500 CAMERA DE TERMOVIZIUNE 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

FLUKE TIS45 CAMERA DE TERMOVIZIUNE 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE 190-502 190-502/S OSCILOSCOP PORTABIL DIGITAL 2X500 MHZ

• 2-canale izolate 500MHz
• Clasa de protectie CAT III 1000 V, CAT IV 600 V
• Multimetru digital dedicat cu 5000 de numărări la modele cu două canale
• Măsurători automate avansate, energie (Vpwm, VA, W, PF) ™ timp (mAs, V/s, w/s)
• Clasa de protectie IP-51 pentru praf şi lichide pentru a rezista in medii dificile
• Porturi USB izolate

 

CLESTE AMPERMETRIC DE CURENT 400A FLUKE 322

• Measures AC current to 400 A with 0.1 A resolution
• Measures AC current to 40 A with 0.01 A resolution, precise low current measurements
• Measures AC volts to 600 V, with 0.1 V resolution to 400.0 V
• Measures DC volts to 600 V, with 0.1 resolution to 400.0 V
• Resistance measurement to 400 O
• Precise measurements with 1.8% basic accuracy

 

DETECTOR PREZENTA TENSIUNE FLUKE LVD1 VOLT LIGHT

• Detects voltages from 40 V AC to 300 V AC
• Non-contact AC voltage detector and LED flashlight
• exclusive dual-sensitivity

 

TESTER ELECTRIC 1000V TENSIUNE CURENT CONTINUITATE FLUKE T5-1000

• 1000V model
• Automatically measures V AC, V DC with precise digital resolution
• 100 A AC Current
• Displays resistance to 1000O

 

TERMOMETRU INFRAROSU FARA CONTACT FLUKE 62 MAX

• Dust and water-resistant: IP54 rated for dust and water resistance.
• Rugged: 3-meter (9.8-foot) drop tested.
• Ergonomically designed: Completely redesigned for a more natural hand fit.
• Large, backlit display: Large screen makes data easier to read, even in dark areas.
• Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements.
• Alarm: Hi and Lo alarms for rapid display of measurements outside the limits

 

RLC-METRU 50 HZ..1 MHZ FLUKE 6306

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display