Cleste curent calibrare proces Fluke 772

Cod: Fluke 772


 

Brosura produs PDF, 0.75 Mb

Descriere

  • 0 to 24 mA Current measure / source / simulate
  • Best in class 0.2 % accuracy
  • 0.01 mA resolution and sensitivity
  • Measure 4 to 20 mA signals without "breaking the loop"
  • Measure mA signals for PLC and control system analog I/O
  • Measure 4 to 20 mA signals with in-circuit measurement
  • Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
  • Source 4 to 20 mA signals for testing control system I/O or I/Ps
  • mA output linear ramp or 25% step output
  • Automatically change the 4 to 20 mA output for remote testing
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features, auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements
 

Accesorii standard

  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet
  • Hanging tool with hook and loop strap
 

Alte produse FLUKE

KIT INREGISTRARE TENSIUNE AC LA DISTANTA FLUKE FLK-CNX V3000 KIT

• masuratori de tensiune c.a. si c.c. true-rms, la 1.000 V
• curent c.a. si c.c. true-RMS, cu o rezolutie de 0,01 mA
• Masuratori de tensiune c.a. true-RMS pâna la 1000 V
• memorie de înregistrare de pâna la 65.000 de masuratori
• CAT III 1000 V; CAT IV 600 V; IP42


MULTIMETRU DE PROCES FLUKE 787

• 0 to 1000 V DC/AC Voltage measure
• 0 to 1 A Current measure
• 0 to 20 mA, 4 to 24 mA Current source
• DMM and loop calibrator in one tool

 

ESA710 ANALIZOR SECURITATE ELECTRICA APARATURA MEDICALA

• Ecran tactil de 5” cu interfață intuitivă pentru utilizator
• Design mic, portabil, ergonomic, cu mâner integrat
• Automatizarea fluxului de lucru activată de OneQA elimină necesitatea unui laptop
• Capacitatea wireless vă permite să rulați proceduri de testare pe teren și să sincronizați automat rezultatele

 

DETECTOR DE TENSIUNE FLUKE 1AC II VOLTALERT

• CAT IV 1000 V for added protection
• 200 V to 1000 V AC

 

TELEMETRU LASER PORTABIL 30M FLUKE 411D

• Measurement to 30 m (100 ft) with accuracy of 3 mm (0.12 in)
• Instant measurement with one-button operation.
• Easy targeting with bright laser.
• Quick calculation of area and volume.
• Easy addition and subtraction of measurements.
• Designed for indoor and outdoor use.

 

TESTER MULTIFUNCTIONAL TEMPERATURA, UMIDITATE, VITEZA AER, CO, CO2 FLUKE 975

• Temperature -20 °C to 50 °C (-5 °F to 122 °F)
• Velocity 0.25 m/sec to 15 m/sec
• Relative Humidity 10 % to 90 % RH, non-condensing
• CO2 0 to 5000 ppm
• CO 0 to 500 ppm

 

INREGISTRATOR CALITATE TENSIUNE SI PUTERE FLUKE VR1710

• 70 V to 300 V Operating Voltage
• Fast and easy recording of voltage trends, dropouts, and power quality
• Continuous recording of all values with no gaps
• Flicker recording to EN 61000-4-15, individual harmonic and THD values
• Min, Max, and Average RMS values


LOGGER MONITORIZARE ENERGIE TRIFAZATA FLUKE MEMOBOX 1744/ 1744 BASIC

• monitor & logging: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
• measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
• Plug and play
• Determines the root cause
• Monitors power for the long-term
• 0.1% voltage accuracy IEC61000-4-30 Class-A compliant
• IP65 water-proof

 

TESTER INSTALATII ELECTRICE 250V-1000V FLUKE 1652C

• Test voltage: 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results

 

CLESTE POWERMETRIC CU ANALIZOR PUTERE FLUKE 345

• 2000A AC/DC current
• 600 V CAT IV power analyzer
• Data logging
• Troubleshoot harmonics
• Inrush current