Filtre de putere protectie radiatii RFI/ EMI curent redus scurgere pamant aplicatii mobile 6..100A ETS-Lindgren N242X

Cod: ETS-Lindgren N242X


 

Brosura produs PDF, 0.29 Mb

Descriere

  • Suitable for mobile installations
  • Extremely low current leakage
  • Over 100dB insertion loss from 150 kHz to 10 GHz
  • Fully accessible end chambers
  • RoHS compliant and CE marked for compliance with the low voltage directive

 

Applications

  • Military field installations
  • Commercial installations using motor generator sets
  • Filtering of mains supplies where maximum safety is required
  • Under certain circumstances, the N242x filters may be used with earth leakage safety cut-outs (please consult the sales office for these types of applications)

 

Electrical Specifications

Part #

Current Max

Leakage Current Per Volt (N-E)

Voltage Max

# of Lines

Voltage Drop on Full Load in 250V 50/60/Hz System/Line

DC Resitance Per Line

N2420

6 A

2 mA

250 V

2

1 V

0.1 O

N2421

6 A

2 mA

440/250 V

4

1 V

0.1 O

N2422

32 A

8 mA

250 V

2

0.4 V

0.015 O

N2423

32 A

8 mA

440/250 V

4

0.4 V

0.015 O

N2424

63 A

8 mA

250 V

2

0.3 V

0.03 O

N2425

63 A

8 mA

440/250 V

4

0.3 V

0.03 O

N2426

100 A

10 mA

250 V

2

0.5 V

0.02 O

N2427

100 A

10 mA

440/250 V

4

0.5 V

0.02 O

 

Alte produse ETS-LINDGREN

ANTENA LOG-PERIODICA LINIAR POLARIZATA DE MARE PUTERE 200..1 GHZ ETS-LINDGREN 3152

• Frequency Minimum 200 MHz
• Frequency Maximum 1000 MHz
• Input Impedance 50 ?
• SWR 1.5:1 average, 2:1 maximum
• Maximum RF input power 1 kW
• RF Connector N Type
• Pneumatically Driven Polarization
• Ideal for Immunity Testing Per 2004/144/EC and ISO-11451-2

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

CAMERA ECRANATA ACUSTIC TESTARE DISPOZITIVE DIMENSIUNI MICI ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

ANTENA DIPOL REZONANT 30 MHZ..1 GHZ ETS-LINDGREN 3121D

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50W-260W
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA HORN GHID PENTRU MASURATORI EMC 1..18 GHZ ETS-LINDGREN 3117

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Peak Power 400 W
• Polarization linear

 

ANTENA ACTIVA BUCLA DE RECEPTIE ECRANATA 1 KHZ..30 MHZ ETS-LINDGREN 6507

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 10 V/m
• Connectors BNC (f)
• Dynamic Range 116 dB @ 1 MHz , 76 dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

FILTRE PROTECTIE RETEA MONOFAZATA APLICATII RFI/EMI PUTERE & CURENT INALT 400..800A ETS-LINDGREN N2510

• >3000 Amp capability
• Fully accessible end chambers
• 80 dB Insertion Loss From 100 kHz to 10 GHz
• Excellent strength to weight ratio
• RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
• High current capability
• Compact design

 

ANTENA HORN DESCHISA CUADRI-CREASTA 700 MHZ..10 GHZ ETS-LINDGREN 3164-08

• Frequency Minimum 700 MHz
• Frequency Maximum 10 GHz
• Cross Polarization Isolation >20 dB
• Impedance 50 ?
• Connector Input Power SMA Female (2)
• 700 MHz - 10 GHz Frequency Range
• Linear or Circular Polarization (With Hybrid)

 

ANTENA MONOPOL ACTIV DE RECEPTIE 30 HZ..50 MHZ ETS-LINDGREN 3301C

• Frequency Minimum 30 Hz
• Frequency Maximum 50 MHz
• Connectors BNC (f)
• Impedance (Nominal) 50 ?
• Polarization linear
• 30 hours of continuous operation in a single charge

 

CELULA REVERBERANTA TESTE EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE RADIATA 1..40 GHZ ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements