Filtre de putere protectie radiatii RFI/ EMI curent redus scurgere pamant aplicatii mobile 6..100A ETS-Lindgren N242X

Cod: ETS-Lindgren N242X


 

Brosura produs PDF, 0.29 Mb

Descriere

  • Suitable for mobile installations
  • Extremely low current leakage
  • Over 100dB insertion loss from 150 kHz to 10 GHz
  • Fully accessible end chambers
  • RoHS compliant and CE marked for compliance with the low voltage directive

 

Applications

  • Military field installations
  • Commercial installations using motor generator sets
  • Filtering of mains supplies where maximum safety is required
  • Under certain circumstances, the N242x filters may be used with earth leakage safety cut-outs (please consult the sales office for these types of applications)

 

Electrical Specifications

Part #

Current Max

Leakage Current Per Volt (N-E)

Voltage Max

# of Lines

Voltage Drop on Full Load in 250V 50/60/Hz System/Line

DC Resitance Per Line

N2420

6 A

2 mA

250 V

2

1 V

0.1 O

N2421

6 A

2 mA

440/250 V

4

1 V

0.1 O

N2422

32 A

8 mA

250 V

2

0.4 V

0.015 O

N2423

32 A

8 mA

440/250 V

4

0.4 V

0.015 O

N2424

63 A

8 mA

250 V

2

0.3 V

0.03 O

N2425

63 A

8 mA

440/250 V

4

0.3 V

0.03 O

N2426

100 A

10 mA

250 V

2

0.5 V

0.02 O

N2427

100 A

10 mA

440/250 V

4

0.5 V

0.02 O

 

Alte produse ETS-LINDGREN

ANTENA HORN DESCHISA CUADRI-CREASTA 400 MHZ..10 GHZ ETS-LINDGREN 3164-10

• Frequency Minimum 400 MHz
• Frequency Maximum 10 GHz
• VSWR Ratio (AVG) 5:1 maximum, 1.75:1 average
• Maximum Continuous Power 100 watts @ 400 MHz, 20 watts @ 10 GHz
• Impedance (Nominal) 50 ?

 

TESTER EMF CAMP ELECTRIC & MAGNETIC RF CONFORM CU STANDARDE INDUSTRIALE 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

FILTRE DE PUTERE PROTECTIE RADIATII RFI/ EMI CURENTI 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

ANTENA HORN GHID DE UNDA DUBLU CREASTA 200 MHZ..2.5 GHZ ETS-LINDGREN 3106B

• Frequency Minimum 200 MHz
• Frequency Maximum 2.5 GHz
• Connectors Type N (f)
• Impedance (Nominal) 1600 W
• Maximum Continuous Power 800 W
• Pattern Type directional

 

ANTENA HORN PENTRU MASURATORI EMC 18..40 GHZ ETS-LINDGREN 3116B

• Frequency Minimum 18 GHz
• Frequency Maximum 40 GHz
• VSWR Ratio (AVG) 2.5:1 max
• Maximum Continuous Power 20 W
• Peak Power 200 W
• Impedance (Nominal) 50 ?

 

ANTENA LOG-PERIODICA LINIAR POLARIZATA DE MARE PUTERE 200..1 GHZ ETS-LINDGREN 3152

• Frequency Minimum 200 MHz
• Frequency Maximum 1000 MHz
• Input Impedance 50 ?
• SWR 1.5:1 average, 2:1 maximum
• Maximum RF input power 1 kW
• RF Connector N Type
• Pneumatically Driven Polarization
• Ideal for Immunity Testing Per 2004/144/EC and ISO-11451-2

 

ANTENA HORN DESCHISA CUADRI-CREASTA 300 MHZ..6 GHZ ETS-LINDGREN 3164-06

• Frequency Minimum 300 MHz
• Frequency Maximum 6 GHz
• Connectors SMA Female (2)
• Cross Polarization Isolation >25 dB
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Linear or Circular Polarization (With Hybrid)

 

FILTRE EMI DE PUTERE RETELE MONOFAZATE APLICATII TEMPEST/ EMC 32..120A ETS-LINDGREN N192X

• Current Range 32 to 250 Amperes
• Very High RF Attenuation
• Fully Tested for Attenuation Performance
• Durable Construction
• CE Marked

 

ANTENA DIPOL LOG-PERIODIC 80 MHZ..2 GHZ ETS-LINDGREN 3144

• Frequency Minimum 80 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW

 

ANTENA DIPOL DE PRECIZIE CU EMISIE OMNIDIRECTIONALA TEST IMUNITATE ELECTROMAGNETICA 440..3010 MHZ ETS-LINDGREN 3125

• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
• IEEE SCC 34 Design
• Designed for AAMI/FDA Test Requirements