Filtre de putere protectie radiatii RFI/ EMI curent redus scurgere pamant aplicatii mobile 6..100A ETS-Lindgren N242X

Cod: ETS-Lindgren N242X


 

Brosura produs PDF, 0.29 Mb

Descriere

  • Suitable for mobile installations
  • Extremely low current leakage
  • Over 100dB insertion loss from 150 kHz to 10 GHz
  • Fully accessible end chambers
  • RoHS compliant and CE marked for compliance with the low voltage directive

 

Applications

  • Military field installations
  • Commercial installations using motor generator sets
  • Filtering of mains supplies where maximum safety is required
  • Under certain circumstances, the N242x filters may be used with earth leakage safety cut-outs (please consult the sales office for these types of applications)

 

Electrical Specifications

Part #

Current Max

Leakage Current Per Volt (N-E)

Voltage Max

# of Lines

Voltage Drop on Full Load in 250V 50/60/Hz System/Line

DC Resitance Per Line

N2420

6 A

2 mA

250 V

2

1 V

0.1 O

N2421

6 A

2 mA

440/250 V

4

1 V

0.1 O

N2422

32 A

8 mA

250 V

2

0.4 V

0.015 O

N2423

32 A

8 mA

440/250 V

4

0.4 V

0.015 O

N2424

63 A

8 mA

250 V

2

0.3 V

0.03 O

N2425

63 A

8 mA

440/250 V

4

0.3 V

0.03 O

N2426

100 A

10 mA

250 V

2

0.5 V

0.02 O

N2427

100 A

10 mA

440/250 V

4

0.5 V

0.02 O

 

Alte produse ETS-LINDGREN

SONDA MASURA CAMP MAGNETIC 300 KHZ..300 MHZ ETS-LINDGREN HI-4433

• Frequency Range: 300 kHz - 300 MHz
• Magnetic Field Sensing: 5-300 MHz
• Automatic Continuous Zeroing
• Data from each axis can be viewed individually
• Isotropic Detection

 

TESTER EMF CAMP ELECTRIC & MAGNETIC RF CONFORM CU STANDARDE INDUSTRIALE 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

ANTENA ACTIVA BUCLA DE RECEPTIE 10 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 5 V/m
• Connectors BNC (f)
• Dynamic Range 125 dB @ 1 MHz, 85dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA MONOPOL ACTIV DE RECEPTIE 30 HZ..50 MHZ ETS-LINDGREN 3301C

• Frequency Minimum 30 Hz
• Frequency Maximum 50 MHz
• Connectors BNC (f)
• Impedance (Nominal) 50 ?
• Polarization linear
• 30 hours of continuous operation in a single charge

 

ANTENA SPIRALA CONICA LOGARITMICA 200 MHZ..1 GHZ ETS-LINDGREN 3101

• Frequency Minimum 200 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 150 W
• Polarization circular
• VSWR 2.4:1
• Extremely low VSWR
• Individually calibrated

 

SONDA DE INJECTIE CURENT 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

ANTENA DUBLU POLARIZATA MATRICE VIVALDI ECRANATA CU MATERIAL ABSORBANT 700 MHZ..6 GHZ ETS-LINDGREN 3165-01

• Frequency Minimum 700 MHz
• Frequency Maximum 6 GHz
• Cross Polarization Isolation > 25 dB
• Impedance 50 ?
• Low Reflectivity
• Dual Linearly Polarized
• Low VSWR with High Directivity

 

ANTENA DIPOL DE PRECIZIE CALIBRARE & MASURA RIPLU COMUNICATII MOBILE SI INTERNET CTIA 450..5000 MHZ ETS-LINDGREN 3126

• Range of Frequencies to Cover Wireless Device Bands: 450…5000 MHz
• Meet CTIA +/- 0.1 dB Symmetry Requirement
• Precision Gain for Range Calibration

 

ANTENA HORN GHID PENTRU MASURATORI EMC 1..18 GHZ ETS-LINDGREN 3117

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Peak Power 400 W
• Polarization linear

 

CAMERA ECRANATA ACUSTIC TESTARE DISPOZITIVE DIMENSIUNI MICI ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011