Filtre protectie retea monofazata aplicatii RFI/EMI putere & curent inalt 400..800A ETS-Lindgren N2510

Cod: ETS-Lindgren N2510


 

Brosura produs PDF, 0.3 Mb

Descriere

  • >3000 Amp capability
  • Fully accessible end chambers
  • 80 dB Insertion Loss From 100 kHz to 10 GHz
  • Excellent strength to weight ratio
  • RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
  • High current capability
  • Compact design

  

Applications

  • High current power circuits
  • EMP installations

 

DC Resistance Per Line

0.15 ? - 0.15 ?

Case Temp Rise On Full Load

+20 °C - +20 °C

Current Max

800 A - 400 A

Frequency

50/60 Hz - 400 Hz

Full Load Dissipation

1.3 KW - 1.3 KW

Max. Recom. Case Temp On Full Load

+70 °C - +70 °C

No. of Lines

1 - 1

Series Inductance Per line

8.75 uH - 8.75 uH

Shunt Capacitance Per Line

64 uF - 64 uF

Voltage Drop on Full Load in 350V 50/60Hz System/Line

3 V - 3 V

Voltage Frequency Maximum

440/250 - 120

 

Alte produse ETS-LINDGREN

DIPOL SFERIC UNIVERSAL GENERARE RADIATII ELECTROMAGNETICE EMI ETS-LINDGREN USDS

• Portable EMI Source for Quick Test Site Characterization and Site-to-Site Comparisons
• Horizontal and Vertical Polarizations
• Selectable Pulse Mode for Testing Quasi-Peak Detectors
• 10 MHz - 10 GHz Frequency Range
• Four Switch Selectable Fundamental Frequencies: 10 MHz, 64 MHz, 100 MHz,133 MHz

 

CAMERA ECRANATA TESTARE EMI/RFI ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

CAMERA ECRANATA ACUSTIC TESTARE DISPOZITIVE DIMENSIUNI MICI ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

ANTENA DIPOL DE PRECIZIE CALIBRARE & MASURA RIPLU COMUNICATII MOBILE SI INTERNET CTIA 450..5000 MHZ ETS-LINDGREN 3126

• Range of Frequencies to Cover Wireless Device Bands: 450…5000 MHz
• Meet CTIA +/- 0.1 dB Symmetry Requirement
• Precision Gain for Range Calibration

 

FILTRE DE PUTERE PROTECTIE RADIATII RFI/ EMI CURENT REDUS SCURGERE PAMANT APLICATII MOBILE 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

SONDE MASURA CURENTI 10 KHZ..1000 MHZ ETS-LINDGREN

• 10 kHz..1000 MHz Frequency ranges
• For Standards Testing and Pre-compliance Applications
• Measures RF Current Without Direct Connection

 

SONDA DE INJECTIE CURENT 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

FILTRE PROTECTIE RETEA MONOFAZATA APLICATII RFI/EMI PUTERE & CURENT INALT 400..800A ETS-LINDGREN N2510

• >3000 Amp capability
• Fully accessible end chambers
• 80 dB Insertion Loss From 100 kHz to 10 GHz
• Excellent strength to weight ratio
• RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
• High current capability
• Compact design

 

ANTENA HORN DESCHISA CUADRI-CREASTA 2..18 GHZ ETS-LINDGREN 3164-05

• Frequency Minimum 2 GHz
• Frequency Maximum 18 GHz
• Connectors SMA Female
• Cross Polarization Isolation >24 dB
• Impedance (Nominal) 50 ?
• Maximum Power 25 W
• Pattern Type directional
• Polarization dual linear

 

BOBINA HELMHOLTZ MONOAXIALA GENERARE CAMP MAGNETIC UNIFORM FRECVENTE JOASE ETS-LINDGREN 6400

• Excellent for Magnetic Immunity Testing
• A Source for Calibration
• Custom Models Available