Celula GTEM test, masura, incercari emisii radiatii electromagnetice si imunitate EMC ETS-Lindgren 5411

Cod: ETS-Lindgren 5411


 

Brosura produs PDF, 0.93 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

1 kW

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq 1.50:1
Characteristic Freq 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Two AC receptacles
  • Forced air ventilation
  • Working supervisor for installation is provided. (Outside North America, call factory)
  • Removable bolt-on feed section
  • Additional maintenance kit
  • Three N-type connectors
  • Customer will need to provide manpower and specific tools
  • Shipped disassembled
  • Air compressor for manipulator brake system
  • Manual emissions correlation software (on request)
  • 5400 GTEM! Series manual
  • 7/16" DIN to type "N" adaptor
  • One fiber optic penetration
  • ETS-Lindgren absorber material
  • One 20 amp, 2 line filter
  • Mobile base with locking casters
  • Blank feed-thru panel without frame
  • Additional copy of emissions correlation software
  • Primary door 27" W x 36.42" H clear opening (68.6 cm x 92.5 cm)
  • Individually characterized with results of TDR and VSWR tests
 

Optiuni recomandate

  • Window with frame (added to primary door)
  • Blank feed-thru panel, installed
  • GTEM! Theory and training - 2 days
  • Power distribution box
  • Additional 30 amp filter, three phase
  • Feed-thru panel with 3 "N" connectors and 1 fiber optic penetration, uninstalled
  • Secondary door with window
  • Secondary door without window
  • Blank feed-thru panel, uninstalled, no frame assembly
  • Additional 20 amp filter, single phase
  • Automated manipulator
  • Dual telephone filter (same as RP59001)
  • AC power filter, .5 amps, 120 V
  • High voltage feed section
  • Additional primary door without window
  • Manual manipulator
  • DC power filter with banana jacks
  • Illumination kit
  • Pneumatic brake kit upgrade for manipulators with electric brake systems
  • Additional 30 amp filter, single phase
 

Alte produse ETS-LINDGREN

STABILIZATOARE IMPEDANTA LINIE DE RETEA ETS-LINDGREN

• Insulated Plugs for Safer Power Connections
• Coils Matched for Application
• Individually Calibrated
• One Piece, Multi-Line Design for Convenience


ANTENA HORN DESCHISA CUADRI-CREASTA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

ANTENA BICONICA TRANSMISIE-RECEPIE 20..200 MHZ ETS-LINDGREN 3104C

• Frequency Minimum 20 MHz
• Frequency Maximum 200 MHz
• Connectors Type N (f)
• FS-600 High Performance Hybrid Ferrite Tile Polyurethane Dielectric 200 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Pattern Type omnidirectional
• Peak Power 100 W
• Polarization linear

 

ANTENA HORN LINIAR POLARIZATA OCTAVA 1..8 GHZ ETS-LINDGREN 3161

• Frequency Minimum 1 GHz
• Frequency Maximum 8 GHz
• Pattern Type directional
• Polarization linear
• Constant Antenna Factor Over Frequency
• Complete with Feed, Waveguide, Mount

 

TESTER CURENT RF INDUS 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

ANTENA DIPOL REZONANT 30 MHZ..1 GHZ ETS-LINDGREN 3121D

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50W-260W
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA LOG-PERIODICA POLARITATE LINIARA 100 MHZ..1 GHZ ETS-LINDGREN 3150

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors 7/8 EIA Flange (others available)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type directional
• Polarization linear

 

CAMERA ECRANATA TESTARE EMI/RFI ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

TESTER CAMP ELECTROMAGNETIC RF ETS-LINDGREN HI-2200

• Handstrap & Safety Lanyard Mount
• Optional Fiber Optic Link
• Interchangeable Probe Heads
• Small/Lightweight for minimal field perturbance
• Broadband Frequency Range
• Economical Solution to Broadcast/Telecom Safety Monitoring Needs & Environmental Monitoring

 

TESTER CAMP MAGNETIC 2..400 KHZ ETS-LINDGREN HI-3637

• 0.06 mG - 400 G (with 100X probe)
• 2 - 400 kHz
• True RMS Detection
• Three concentric orthogonal field sensors