Celula GTEM test, masura, incercari emisii radiatii electromagnetice si imunitate EMC ETS-Lindgren 5411

Cod: ETS-Lindgren 5411


 

Brosura produs PDF, 0.93 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

1 kW

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq 1.50:1
Characteristic Freq 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Two AC receptacles
  • Forced air ventilation
  • Working supervisor for installation is provided. (Outside North America, call factory)
  • Removable bolt-on feed section
  • Additional maintenance kit
  • Three N-type connectors
  • Customer will need to provide manpower and specific tools
  • Shipped disassembled
  • Air compressor for manipulator brake system
  • Manual emissions correlation software (on request)
  • 5400 GTEM! Series manual
  • 7/16" DIN to type "N" adaptor
  • One fiber optic penetration
  • ETS-Lindgren absorber material
  • One 20 amp, 2 line filter
  • Mobile base with locking casters
  • Blank feed-thru panel without frame
  • Additional copy of emissions correlation software
  • Primary door 27" W x 36.42" H clear opening (68.6 cm x 92.5 cm)
  • Individually characterized with results of TDR and VSWR tests
 

Optiuni recomandate

  • Window with frame (added to primary door)
  • Blank feed-thru panel, installed
  • GTEM! Theory and training - 2 days
  • Power distribution box
  • Additional 30 amp filter, three phase
  • Feed-thru panel with 3 "N" connectors and 1 fiber optic penetration, uninstalled
  • Secondary door with window
  • Secondary door without window
  • Blank feed-thru panel, uninstalled, no frame assembly
  • Additional 20 amp filter, single phase
  • Automated manipulator
  • Dual telephone filter (same as RP59001)
  • AC power filter, .5 amps, 120 V
  • High voltage feed section
  • Additional primary door without window
  • Manual manipulator
  • DC power filter with banana jacks
  • Illumination kit
  • Pneumatic brake kit upgrade for manipulators with electric brake systems
  • Additional 30 amp filter, single phase
 

Alte produse ETS-LINDGREN

SISTEM MONITORIZARE CAMP ELECTROMAGNETIC DE BANDA LARGA 10 KHZ..40 GHZ ETS-LINDGREN HI-6100 E-FIELD MONITOR

• HI-6100 Field Monitor with 4 Probe Input Channels
• Large Color LCD Display
• IEEE-488, RS-232, USB Interfaces
• USB & RS232 Interface Modules available for Record & View measurements
• Electric Field Probes for 10 kHz..40 GHz frequencies

 

CELULA REVERBERANTA TESTE EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE RADIATA 1..40 GHZ ETS-LINDGREN SMART 1000

• Automated Measurement with Optional Software
• Field Uniformity Better than 3 dB Over Operating Range
• Compact Bench-Top Design
• Frequency Range of 1.0 GHz to 40 GHz
• Radiated Immunity and Emissions Measurements

 

ANTENA DIPOL LOG-PERIODIC 80 MHZ..2 GHZ ETS-LINDGREN 3144

• Frequency Minimum 80 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW

 

ANTENA DE BANDA LARGA OMNIDIRECTIONALA PENTRU MONITORIZARE SPECTRU 500 MHZ..18 GHZ ETS-LINDGREN 3181

• Frequency Minimum 500 MHz
• Frequency Maximum 18 GHz
• Connectors SMA (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 200 watts @ 500 MHz, 25 watts @ 18 GHz

 

INCINTA ECRANATA TESTARE DISPOZITIVE WIRELESS ETS-LINDGREN 5247

• Roll-About Casters
• Portable RF Shielded Enclosure for OTA measurements
• >80 dB Typical RF Isolation
• RF Absorber Lined
• Dual Polarized Horn Antenna
• 700 MHz - 10 GHz Frequency Range
• Linear & Circular Polarization

 

ANTENA SPIRALA CONICA LOGARITMICA 100 MHZ..1 GHZ ETS-LINDGREN 3103

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Two Year Warranty
• Extremely low VSWR

 

ANTENA BICONICA TESTARE IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear

 

ANTENA HORN GHID MICROUNDE DUBLU CREASTA 750 MHZ..18 GHZ ETS-LINDGREN 3115

• Frequency Minimum 750 MHz
• Frequency Maximum 18 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 500 W
• Pattern Type directional
• Polarization linear

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

GENERATOR CAMP ELECTRIC ORIZONTAL/ VERTICAL 10 KHZ..30 MHZ ETS-LINDGREN 5502

• Generates vertical or horizontal electric field
• Generates Fields 200 v/m in the 10 kHz to 30 MHz Frequency Range
• Fully Adjustable Height and Separation of Main Conductors
• Large Immunity Volume
• Chamber Supported