Camera ecranata acustic testare dispozitive dimensiuni mici ETS-Lindgren SD

Cod: ETS-Lindgren SD


 

Brosura produs PDF, 0.37 Mb

Descriere

  • Acoustically Controlled Test Environment
  • Survey and/or Engineering Grade Measurement
  • Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

APPLICATIONS

  • Automotive Components
  • Quality Assurance/Comparative Analysis
  • Testing of Telephone Handsets or Mounted Transducers for Noise Quality
  • Insertion Measurements of Hearing Aids
  • Evaluation Testing of Microphones or Preamplifiers for Noise Cancellation, Conductivity and Noise Emissions
  • Testing Noise Emissions of Small Parts or Components
  • Head & Torso Testing (SD3)
  • IT Product Noise Testing

 

Product Features and Options

Model #

Chamber Dims Outside (L x W x H)

Chamber Dims Inside (L x W x H)

Features

Applications

Some Applicable Standards

SD

91.4 cm x 86.4 cm x 91.4 cm
(36 in. x 34 in. x 36 in.)

71.1 cm x 66.0 cm x 71.1 cm
(28 in. x 26 in. x 28 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (4)
AS-A504 Walls

Quality Control Comparative Analysis

ISO 3744
ISO 3746
ISO 532B
ISO 11201

SD1

111.8 cm x 111.8 cm x 111.8 cm
(44 in. x 44 in. x 44 in.)

91.4 cm x 91.4 cm x 91.4 cm
(36 in. x 36 in. x 36 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (4)
AS-A504 Walls
Light(1)

Sound Power and
Sound Pressure of
Auto Parts,Computer Parts, and Small Parts

ISO 3744
ISO 3746
ISO 532B
ISO 11201
GMW7293

SD2

152.4 cm x 152.4 cm x 162.6 cm
(60 in. x 60 in. x 64 in.)

121.9 cm x 121.9 cm x 132.1 cm
(48 in. x 48 in. x 52 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (2)
AS-A506 Walls
Light(1)

Engineering Test of Small Parts

ISO 3744
ISO 3746
ISO 532B
ISO 11201
GMW7293
MS14011

SD3

127 cm x 127 cm x 241.3 cm
(50 in. x 50 in. x 95 in.)

106.7 cm x 106.7 cm x 213.4 cm
(42 in. x 42 in. x 84 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (2)
AS-A504 Walls
Light(1)

Head & Torso Testing
Speech Intelligibility
Codec Scoring
End to End Signal Integrity

ISO 3744
ISO 3746
ISO 532B
ISO 11201

 

Accesorii standard

  • Acoustic Walls, Ceiling, and Floor
  • Acoustically Engineered Roof Integrated Ventilation System
  • Light (SD1, SD2, SD3 Only)
  • Sound Absorbing Perforated Steel Interior (Walls and Ceiling)
  • Panelized Floor (Reflective)
  • Floor Vibration Rails, SD2 & SD3
  • Floor Vibration Pads, SD & SD1
  • Cable Ports
    -- 1 ea. 5.1 cm (2 in.)
    -- 1 ea. 2.5 cm (1 in.)
  • Acoustic Door with Window
 

Optiuni recomandate

  • Test Stands (Not Available on SD3)
  • Absorptive Mini Wedges
  • Interior Perforated Floor
  • Stainless Steel Construction
  • Light (SD Only)
  • Ventilation Silencers (SD3 Only)
 

Alte produse ETS-LINDGREN

SONDA DE INJECTIE CURENT 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

FILTRE DE PUTERE PROTECTIE RADIATII RFI/ EMI CURENTI 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

ANTENA LOG-PERIODICA LINIAR POLARIZATA DE MARE PUTERE 20..220 MHZ ETS-LINDGREN 3151

• 20 MHz to 220 MHz frequency range
• High power feed handles up to 5 kW RF input power
• Space saving design features tophat-loaded, low-frequency elements
• Mounted on wheeled base for easy mobility

 

ANTENA DE BANDA LARGA OMNIDIRECTIONALA 1..18 GHZ ETS-LINDGREN 3183

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1GHz, 25 watts @ 18 GHz
• Chamber Characterization
• Broadband Spectrum Monitoring

 

ANTENA HORN DESCHISA CUADRI-CREASTA 2..18 GHZ ETS-LINDGREN 3164-05

• Frequency Minimum 2 GHz
• Frequency Maximum 18 GHz
• Connectors SMA Female
• Cross Polarization Isolation >24 dB
• Impedance (Nominal) 50 ?
• Maximum Power 25 W
• Pattern Type directional
• Polarization dual linear

 

GENERATOR CAMP ELECTRIC VERTICAL UNIFORM 10 KHZ..30 MHZ ETS-LINDGREN 5503

• Generates large area uniform vertical electric field
• 10 kHz - 30 MHz frequency range
• Accommodates various EUT sizes with adjustable height feature
• Temperature maintained with external forced-air cooling, and monitored by temperature sensor
• Easy to assemble/disassemble and remove from the chamber

 

ANTENA DE BANDA LARGA BICONICA 30 MHZ..1 GHZ ETS-LINDGREN 3180

• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W

 

TESTER AUTOMATIC MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE CUPTOARELE CU MICROUNDE ETS-LINDGREN HI-1710A

• Digital Alarm Set
• Auto-ranging
• RS-232 Interface
• Removable Sensing Probe
• Optional Remote Zero
• Analog bar graph
• Serial Printer Output

 

ANTENA HORN PIRAMIDAL CU GENERARE CAMP ELECTRIC TESTARE EMC AUTO GMW 3097 SI ES-XW7T-1A278-AC 1.2..1.4 GHZ ETS-LINDGREN 3162-01

• Frequency Minimum 1.2 GHz
• Frequency Maximum 1.4 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 550 W
• Pattern Type directional
• GMW 3097
• ES-XW7T-1A278-AC

 

ANTENA BUCLA PASIVA DE TESTAT ECRANARE SI IMUNITATE RADIATII 20 HZ..5 MHZ ETS-LINDGREN 6511

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear