Celula GTEM test, masura, incercari emisii electromagnetice si imunitate EMC ETS-Lindgren 5402

Cod: ETS-Lindgren 5402


 

Brosura produs PDF, 0.12 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f < 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

50 W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq < 1.50:1
Characteristic Freq < 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Manual emissions correlation software (on request)
  • 7/16" DIN to type "N" adaptor
  • Individually characterized with results of TDR and VSWR tests
  • 5400 GTEM! Series manual
  • One removable access port in floor
  • ETS-Lindgren absorber material
  • Primary door 6.3" W x 9.1" H clear opening (16 cm x 23 cm)
  • Completely assembled
 

Optiuni recomandate

  • Blank connector panel
 

Alte produse ETS-LINDGREN

SONDA DE INJECTIE CURENT 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

ANTENA BUCLA PASIVA DE TESTAT ECRANARE SI IMUNITATE RADIATII 10 KHZ..30 MHZ ETS-LINDGREN 6512

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

CAMERA DE TEST IZOLATA RF MASURATORI EMC SI ECRANARE ETS-LINDGREN 5230

• Standard dimenssions 600 x 500 x 500 mm
• Progressive Latching
• Large Working Interior
• Up to 120 dB RF Isolation

 

ANTENA HORN GHID DE UNDA DUBLU CRESTATA 100 MHZ..1 GHZ ETS-LINDGREN 3112

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 800 W
• Maximum Power 2 kW

 

CAMERA ECRANATA ACUSTIC TESTARE DISPOZITIVE DIMENSIUNI MICI ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

STABILIZATOARE IMPEDANTA LINIE DE RETEA ETS-LINDGREN

• Insulated Plugs for Safer Power Connections
• Coils Matched for Application
• Individually Calibrated
• One Piece, Multi-Line Design for Convenience


ANTENA LOG-PERIODICA LINIAR POLARIZATA DE MARE PUTERE 200..1 GHZ ETS-LINDGREN 3152

• Frequency Minimum 200 MHz
• Frequency Maximum 1000 MHz
• Input Impedance 50 ?
• SWR 1.5:1 average, 2:1 maximum
• Maximum RF input power 1 kW
• RF Connector N Type
• Pneumatically Driven Polarization
• Ideal for Immunity Testing Per 2004/144/EC and ISO-11451-2

 

ANTENA HORN DESCHISA CUADRI-CREASTA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

INTERFATA WIRELESS TESTARE TELEFOANE MOBILE IN COMUNICATII CELULARE ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz