Celula GTEM test, masura, incercari emisii electromagnetice si imunitate EMC ETS-Lindgren 5402

Cod: ETS-Lindgren 5402


 

Brosura produs PDF, 0.12 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f < 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

50 W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq < 1.50:1
Characteristic Freq < 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Manual emissions correlation software (on request)
  • 7/16" DIN to type "N" adaptor
  • Individually characterized with results of TDR and VSWR tests
  • 5400 GTEM! Series manual
  • One removable access port in floor
  • ETS-Lindgren absorber material
  • Primary door 6.3" W x 9.1" H clear opening (16 cm x 23 cm)
  • Completely assembled
 

Optiuni recomandate

  • Blank connector panel
 

Alte produse ETS-LINDGREN

STABILIZATOARE IMPEDANTA LINIE DE RETEA ETS-LINDGREN

• Insulated Plugs for Safer Power Connections
• Coils Matched for Application
• Individually Calibrated
• One Piece, Multi-Line Design for Convenience


ANTENA DIPOL DE PRECIZIE CU EMISIE OMNIDIRECTIONALA TEST IMUNITATE ELECTROMAGNETICA 440..3010 MHZ ETS-LINDGREN 3125

• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
• IEEE SCC 34 Design
• Designed for AAMI/FDA Test Requirements

 

ANTENA LOG-PERIODICA DIRECTIVA BANDA LARGA 200 MHZ..5 GHZ ETS-LINDGREN 3147

• Frequency Minimum 200 MHz
• Frequency Maximum 5 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 80 W
• Pattern Type directional
• Peak Power 100.0 W
• VSWR 1.2:1

 

ANTENA DE BANDA LARGA BICONICA 30 MHZ..1 GHZ ETS-LINDGREN 3180

• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

SONDE MASURA CURENTI 10 KHZ..1000 MHZ ETS-LINDGREN

• 10 kHz..1000 MHz Frequency ranges
• For Standards Testing and Pre-compliance Applications
• Measures RF Current Without Direct Connection

 

FILTRE DE PUTERE PROTECTIE RADIATII RFI/ EMI CURENT REDUS SCURGERE PAMANT APLICATII MOBILE 6..100A ETS-LINDGREN N242X

• Suitable for mobile installations
• Extremely low current leakage
• Over 100dB insertion loss from 150 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

ANTENA BUCLA CU GENERARE CAMP MAGNETIC FRECVENTA JOASE 20 HZ..50 KHZ ETS-LINDGREN 7603

• Frequency Minimum 20 Hz
• Frequency Maximum 50 kHz
• Connectors Banana Jack (2)
• Impedance (Nominal) 50 ?
• Maximum Input Power 5 A
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA BICONICA MASURA DE PRECIZIE 30..300 MHZ ETS-LINDGREN 3110C

• Frequency Minimum 30 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 250mW

 

FILTRU PUTERE APLICATII TEMPEST/ EMP DE MARE PERFORMANTA CURENTI 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation