Celula reverberanta teste emisii radiatii electromagnetice si imunitate radiata 1..40 GHz ETS-Lindgren Smart 1000

Cod: ETS-Lindgren Smart 1000


 

Brosura produs PDF, 0.1 Mb

Descriere

  • Automated Measurement with Optional Software
  • Field Uniformity Better than 3 dB Over Operating Range
  • Compact Bench-Top Design
  • Frequency Range of 1.0 GHz to 40 GHz
  • Radiated Immunity and Emissions Measurements
    IEC61000-4-21
    MIL-STD-461E
  • Fast Measurement Time
  • Two Year Warranty

 

Electrical Specifications

Frequency Minimum

1.0 GHz

Frequency Maximum

40 GHz

 

Accesorii standard

  • Chamber calibration from 1.0 GHz to 40 GHz per IEC 61000-4-21
  • Two Year Warranty
  • One Type N and one Type K connector for horns
  • Two double ridged horn antennas (mounted)
  • One vertical, one horizontal tuner, with stepper motors
  • SMART 1000 Mini-Reverb Assembly
 

Optiuni recomandate

  • SMARTImm Immunity software
  • Additional N, SMA, 2.9, 3.5, or Type K connectors
  • SMARTEMI Emissions software
 

Alte produse ETS-LINDGREN

FILTRE PUTERE TEMPEST/ EMI/ EMC DE MARE PERFORMANTA CURENTI 16..200A ETS-LINDGREN N500X

• Low power dissipation
• Compact Rugged Construction
• 100dB insertion loss from 40kHz
• Suitable for 400Hz supplies
• Current Range 16 to 200 Amperes

 

TESTER CAMP MAGNETIC 30..2000 HZ ETS-LINDGREN HI-3624

• Isotropic Response
• True RMS Detection
• 100dB Dynamic Range
• Low Cost, True RMS Magnetic Field Measurements

 

ANTENA DIPOL DE PRECIZIE CALIBRARE & MASURA RIPLU COMUNICATII MOBILE SI INTERNET CTIA 450..5000 MHZ ETS-LINDGREN 3126

• Range of Frequencies to Cover Wireless Device Bands: 450…5000 MHz
• Meet CTIA +/- 0.1 dB Symmetry Requirement
• Precision Gain for Range Calibration

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA HORN GHID PENTRU MASURATORI EMC 1..18 GHZ ETS-LINDGREN 3117

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Peak Power 400 W
• Polarization linear

 

ANTENA DE BANDA LARGA BICONICA 30 MHZ..1 GHZ ETS-LINDGREN 3182

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 200 watts

 

ANTENA DIPOL REZONANT 30 MHZ..1 GHZ ETS-LINDGREN 3121D

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50W-260W
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA HORN DESCHISA CUADRI-CREASTA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

INTERFATA WIRELESS TESTARE TELEFOANE MOBILE IN COMUNICATII CELULARE ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz

 

SONDE MASURA CURENTI 10 KHZ..1000 MHZ ETS-LINDGREN

• 10 kHz..1000 MHz Frequency ranges
• For Standards Testing and Pre-compliance Applications
• Measures RF Current Without Direct Connection