Metrel MI3102H Insulating Resistance Tester 2500V CL Electrical Installations EUROTEST XE 2.5kV

Code: Metrel MI3102H MI-3102H CL-EUROTEST-XE 2.5kV


 

Datasheet PDF, 0.35 Mb
 

Description

MI 3102H CL EurotestXE 2,5 kV is the multifunctional measuring instrument which apart from all the necessary functions for complete installation safety testing according to IEC/EN 61557 performs insulation resistance measurement with the test voltage up to 2.5 kV (reading is up to 10 G?) and enables diagnostic test by PI and DAR indexes calculation. 

 

MEASURING FUNCTIONS

  • Insulation resistance with DC voltage
  • PI, DAR calculation
  • Continuity of PE conductors with 200 mA test current with polarity change
  • Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping
  • Line impedance
  • Loop impedance
  • Loop impedance with Trip Lock RCD function
  • TRMS voltage and frequency
  • Phase sequence
  • RCD testing (general and selective, type AC, A)
  • Earth resistance (3-wire and 2 clamps methods)
  • TRMS leakage and load currents (option)
  • Illumination (option)

 

OTHER FEATURES

  • Wide range of insulation test voltages from 100 V to 2500 V, reading up to 10 GO.
  • Insulation diagnostics: Polarisation Index (PI) and Dielectric Absorption Ratio (DAR) calculation.
  • Built-in help screens for referencing on site.
  • Built-in fuse tables for automatic evaluation of the line / loop impedance result.
  • Monitoring of all 3 voltages in real-time.
  • Automatic polarity reversal on continuity test.
  • Loop impedance test without tripping the RCD.
  • Built-in charger and rechargeable batteries as standard accessory.
  • Automated RCD testing procedure.
  • PC SW Eurolink PRO for downloading of test results and report creation.

 

SOFTWARE

PC SW EuroLink PRO is a strong creating tool of professional Visual Inspection Report and Testing Result Report.

 

TECHNICAL DATA

Dimensions (w x h x l): 230 x 103 x 115 mm

Mass (without accessories): 1.3 kg

 

Standard accessories

MI 3102H CL Standard set MI 3102H CL

  • Instrument EurotestXE 2,5 kV
  • Tip commander, 1.5 m
  • Schuko-plug test cable
  • 2.5 kV test lead, 2 x 1.5 m
  • Test lead, 3 x 1.5 m
  • Earth test set (test lead, 4 m; 2 x test lead, 20 m; 2 x test rod)
  • Power supply adapter + 6 NiMH rechargeable batteries, type AA
  • PC Software EuroLink PRO
  • Test probe, 3 pcs (blue, black, green)
  • Crocodile clip, 3 pcs (blue, black, green)
  • RS232 - PS/2 cable
  • USB cable
  • Soft carrying neck belt
  • Soft carrying bag
  • Short instruction manual
  • Instruction manual on CD
  • Handbook on CD
  • Calibration certificate

 

 

More products METREL

PRECISION CURRENT CLAMP METER TRUE RMS METREL MD 9250

• meets overvoltage category CAT IV 1000 V
• TRMS AC, DC voltage measurement;
• TRMS AC, DC current measurement;
• Capacitance measurement;
• Resistance measurement;
• Diode test;
• Frequency measurement;
• Electric field detection;
• Continuity test (acoustic signaling);
• Temperature measurement.

 

METREL MI2086 EUROTEST 61557 ELECTRICAL INSTALLATION TESTER

• DC insulation resistance with test voltages up to 1000V
• PE conductor continuity test
• Loop and Line impedance also without RCD triggering
• RCD test
• Illumination
• Phase sequence in 3-phase systems
• Measurements on earthling and lightning systems with included 2-clamp method (without junctions disassembling).
• Electrical power and consumption measurement,
• current and voltage harmonics measurement,
• phase angle

 

METREL MD9050 PORTABLE DIGITAL HIGH RESOLUTION MULTIMETER MD-9050

• High resolution and accuracy
• 1000V TRMS AC, DC voltage measurement;
• 10A TRMS AC, DC current measurement;
• 60nF..25mF Capacitance measurement;
• 600O..60MO Resistance measurement;
• Diode test;
• 5Hz..1MHz Frequency of digital signals measurement
• Temperature measurement(thermocouple type K included)

 

METREL MD9015 ELECTRICIAN HANDHELD MULTIMETER MD-9015

• 1000V DC, 750V AC voltage measurement;
• 10A AC, DC current measurement;
• 250O..25MO Resistance measurement;
• 2500nF..25mF Capacitance measurement;
• 30Hz..200kHz Frequency Measurement
• Temperature measurement

 

METREL MI3309 DELTAGT SAFETY ANALYZER FOR PORTABLE ELECTRICAL EQUIPMENT

• Functional and visual inspection
• Earth bond resistance
• Insulation resistance
• Insulation resistance of isolated accessible conductive parts
• Substitute leakage current
• Substitute leakage current of isolated accessible conductive parts
• Differential leakage current test
• Touch leakage test
• PRCD test

 

METREL MI3125B ELECTRICAL INSTALATION TESTER 1KV EUROTEST COMBO

• Insulation resistance with DC voltage
• Continuity of PE conductors with 200 mA test current with polarity change
• Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping
• Line impedance
• Loop impedance
• Loop impedance with Trip Lock RCD function
• TRMS voltage and frequency
• Phase sequence
• RCD testing (general and selective, type AC, A and B)
• Earth resistance (3-wire method).

 

VARIABLE TRANSFORMER SINGLE OR THREE PHASE PORTABLE OR DESKTOP METREL

• Single-phase Built-in Variable Auto-Transformers
• Three-phase Built-in Variable Auto-Transformers
• Motor driven Variable Transformers
• Desk top Variable Transformers

 

METREL MI3201 TERAOHM 5KV INSULATION RESISTANCE MEGAOHMMETER 5000V

• Pre-set test voltages: 250V...5000V
• Automated testing - PI, DD, DAR calculations with automated resistance ranging (AR)
• Fault finding
• R(t) graph - Real time resistance against time graph plotting facility
• Faster testing - High 5 mA charging current quickly charges capacitive loads.
• Accurate
• Safe - High CAT IV, 600 V voltage protection

 

LOW COST UNIVERSAL CURRENT CLAMP METER METREL MD 9210

• DC and AC voltage up to 600 V
• AC current measurement up to 600 A
• Resistance measurement
• Continuity test
• Diode test
• Frequency measurement
• Capacitance measurement

 

THREE-PHASE ACTIVE ADAPTER FOR TESTING POLARITY, DIFFERENTIAL LEAKAGE AND RCD'S METREL A1322

• All tests on 3-phase electrical equipment can be carried out, including live leakage test, power, polarity, RCD and Active polarity.
• Simple connection to the PAT/MACHINE tester with automatic detection.
• Simple test procedures, identical to single phase equipment.
• Test sequence for 3-phase tests are automatically set, based on entered test codes and input voltages.