Luxmetru masura iluminanta, PAR, iradianta lumina solara Delta Ohm HD2302.0 HD2302.0VP474

Cod: Delta Ohm HD2302.0 HD2302.0VP474


 

Brosura produs PDF, 0.49 Mb

Descriere

HD2303.0 Device for measuring illuminance, luminance, PAR, irradiance. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Complete with carrying case, instruction manual, 3 batteries. LP471. series probes with SICRAM module are suitable. The probes have to be ordered separately.

 

 

HD2302.0VP474 Radiometer complete with SICRAM module. A pyranometer such as LP PYRA02AV or LP PYRA03AV can be connected. The instrument displays the values in W/m2. The order has to be placed for: instrument, pyra­no­meter and connection cable. The kit includes instrument, module VP474, carrying case, instruction manual, 3 batteries. The pyranometer at choice between LP PYRA02AV or LP PYRA03AV, the cable (CP AA 1.5 or CP AA 1.10) and any other LP471 series probes have to be ordered separately. The kit has to be configured by the manufacturer.

 

Alte produse SENSECA

PIRANOMETRU CLASA A 2A IN CONFORMITATE CU STANDARDUL ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

PLUVIOMETRU MASURA CANTITATE SI DEBIT CADERI PRECIPITATII ATMOSFERICE PLOAIE DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

SONOMETRU INTEGRATOR CLASA I SI CLASA II CU ANALIZA SPECTRALA SI STATISTICA DELTA OHM HD2010UC

• integrating portable sound level meter performing statistical analysis
• maximum low cost and simplicity of use
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 dated 2002, IEC 60651 and IEC 60804
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis

 

PH-METRU TERMOMETRU CU DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

TESTER MONITORIZARE SI ANALIZA CALITATE AER INTERIOR, MONOXID, BIOXID DE CARBON DELTA OHM HD37AB1347

• Datalogger for indoor air quality analysis (IAQ)
• measures: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide)
• Memory capacity of 67,600 records for each of the two inputs.
• Logging interval from 15 seconds to 1 hour.

 

PIRANOMETRU CLASA SECUNDARA MASURA IRADIERE SOLARA DIRECTA SI GLOBALA PE SUPRAFATA PLANA DELTA OHM LP PYRA10

• measures the irradiance on a flat surface (Watt/m2)
• pyranometer classified as Secondary in accordance with ISO 9060
• according to the publication "Guide to Meteorological Instruments and Methods of Observation", fifth edition (1983) of WMO
• LP PYRA 10 PASSIVE *
• LP PYRA 10 AC ACTIVE with CURRENT 4..20 mA output
• LP PYRA 10 AV ACTIVE with VOLTAGE 0..1 V, 0..5 V, 0..10 V output

 

DATALOGGER ANALIZOR MICRO-CLIMA WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

PH-METRU-CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

TESTER LABORATOR PARAMETRI ELECTROCHIMIE: PH, CONDUCTIVITATE, OXIGEN DIZOLVAT, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, CONCENTRATIE DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),