Cod: Delta Ohm HD32.1
Descriere
Technical data HD32.1:
Thanks to specific software: Moderate environments, Hot environments, Cold environments and Discomfort, as well as specific probes, the instrument can perform the following measurements:
• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head (1,7m subject standing; 1,1m subject sitting).
• Air temperature at the height of the abdomen (1,1 m subject standing; 0,6m subject sitting).
• Air temperature at the height of the ankles (0,1 m).
• Temperature at the floor level.
• Net radiation temperature.
• Net radiation.
• Radiant temperature asymmetry.
• Illuminance, luminance, PAR, irradiance, CO and CO2.
According to measurements performed, HD32.1, together with its specific software, calculates the following parameters:
• tr : Mean radiant temperature
• PMV : Predicted Mean Vote
• PPD : Predicted Percentage Dissatisfied
• DR : Draught Rating
• tO : Operative temperature
• IS : Scharlau Index
• DI : Thom Index
• THI : Thermohygrometric Index
• RSI : Relative Strain Index
• SSI : New Summer Simmer Index
• HI : Heat Index
• H : Humidex Index
• Teq : Equivalent Temperature Index
To compute the calculation of these indexes, temperature and relative humidity of the air have to be detected and the measured values to be inserted in the table "Discomfort indexes".
• WBGTIndoor : Wet bulb Globe temperature
• WBGTOutdoor : Wet bulb Globe temperature in the presence of radiation
• SWp : Sweat rate
• Ep : Predicted evaporative heat flow
• PHS : Tre - Water loss - Dlim tre - Dlimloss50 - Dlimloss95
• IREQ : Required clothing insulation
• DLE : Duration Limit Exposure
• RT : Recovery time
• WCI : Wind chill index
• PDv : Percentage Dissatisfied due to vertical temperature difference (head-ankles)
• PDf : Percentage Dissatisfied due to floor temperature
• PD? : Percentage Dissatisfied due to radiant asymmetry
• FLD : Average Day Light Factor
The calculation of the FLD index requires light measurement (photometric probe LP-471PHOT). Requires program "HD32.1 prog. C"
HD32.1 Kit basic: It is composed of HD32.1 instrument, A operating program:
Analysis of the Microclimate, four 1.5V alkaline batteries size C-BABY, instruction manual. The instrument includes atmospheric pressure sensor.
DeltaLog10 Basic moderate environments Software (for operating systems from Windows 98 to Windows7).
Alte produse SENSECA
|
DETECTOR DE PLOAIE SI PRECIPITATII ATMOSFERICE DELTA OHM HD2013.2
• rain detector based on the capacity principle |
|
PIRANOMETRU CU TERMOPILA MASURA RADIATIE SOLARA INCIDENTA GLOBALA DELTA OHM LP PYRA02 PYRA03 PYRA12
• First class pyranometer according to ISO 9060. |
|
TERMOMETRU DE PRECIZIE PORTABIL DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2
• Centesimal thermometer in the range +/-199.99°C, decimal outside this range |
|
DATALOGGER 8-16 CANALE INREGISTRARE TEMPERATURA DELTA OHM HD32.7 HD32.8.8 HD32.8.16
• HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES |
|
DATALOGGER PRESIUNE, TEMPERATURA, DEBIT DELTA OHM DO9704
• Datalogger for pressure, flow rate and temperature measurements with 2 inputs, |
|
ACCELEROMETRU MONO-AXIAL SI ACCELEROMETRU TRIAXIAL ICP VIBRATII MECANICE DELTA OHM
• HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system |
|
DATALOGGER HVACR VITEZA SI DEBIT AER, PRESIUNE, TEMPERATURA, UMIDITATE DELTA OHM DO2003
• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes, |
|
DATALOGGER MULTIFUNCTIONAL CU ANALIZA MICROCLIMA DELTA OHM HD32.1
• Globe temperature |
|
TERMOMETRU DIGITAL PORTABIL SENZOR PT100 -200°C +650°C DELTA OHM HD2307.0
• Thermometer, Pt100 sensor with one input for probes equipped with SICRAM module, |
|
ANEMOMETRU ULTRASONIC MASURA VITEZA SI DIRECTIE VANT TREI AXE DELTA OHM HD2003 HD2003.1
• Determination of the anemometric quantities represented in diverse measurement units: |