Anemometru-Termometru digital Delta Ohm HD2103.1 HD2103.2

Cod: Delta Ohm HD2103.1 HD2103.2


 

Brosura produs PDF, 0.33 Mb

Descriere

Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.

Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.

RS232C/USB output for data transfer in real time to a PC or printer.

Functions: REL, HOLD and auto power off which can be disabled,

IP67 protection degree.

 

Complete with carrying case, instruction manual, 4 batteries, Software DeltaLog 9. The air speed probes, the temperature probes, cable for data downloading have to be ordered separately. TP47Â... series temperature probes are suitable.

 

Alte produse SENSECA

PH-METRU-TERMOMETRU DE LABORATOR CU MASURA PH, MV, POTENTIAL REDOX ORP DELTA OHM HD2205.2

• Bench-top pHmeter-Thermometer with back-lighted display,
• with two BNC inputs, to
• measure pH, mV, ORP with pH, redox, separated reference electrodes,
• one input for a pH/temperature combined probe provided with SICRAM module.
• Datalogger of pH, mV, temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module

 

SONDA FOTOMETRICA EXTERIOR MASURA ILUMINANTA SOLARA DELTA OHM LP PHOT02

• Outdoor photometric probe for measuring ILLUMINANCE (0...150 Klux),
• CIE photopic filter,
• diffuser for cosine correction.
• mVdc output for klux.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors.

 

PH-METRU-CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

PIRANOMETRU CU TERMOPILA MASURA RADIATIE SOLARA INCIDENTA GLOBALA DELTA OHM LP PYRA02 PYRA03 PYRA12

• First class pyranometer according to ISO 9060.
• Complete with: shade disk, sachet with silica-gel crystals, 2 cartridges, levelling device and calibration report.
• On request 5 or 10m cables with connectors

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR CU MASURA REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE TDS DELTA OHM HD2206.2

• Bench-top conductivity meter-Thermometer with back-lighted display,
• with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature
• combined probes with 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger of conductivity or resistivity or TDS and temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.

 

TESTER LABORATOR PARAMETRI ELECTROCHIMICI OXIGEN DIZOLVAT CONCENTRATIE INDEX SATURATIE DELTA OHM HD3409.2

• Bench-top Oxymeter-Thermometer measures dissolved oxygen,
• saturation index by polarographic type combined probes,
• temperature by Pt100 probes with SICRAM module.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

DATALOGGER ANALIZOR MICRO-CLIMA WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

DATALOGGER ANALIZA MONITORIZARE CALITATE MEDIU AER, MONOXID, BIOXID CARBON DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

DATALOGGER ANALIZOR MICRO-CLIMA WBGT PMV PPD DELTA OHM HD32.3 HD32.3A

• Analysis of hot environments using WBGT index
• Analysis of the moderate warm environments using PMV index and PPD index
• Logging
• Start and stop can be set automatically with the auto-start function
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.