Analizor audio sunet Clasa I cu datalogger, analiza spectru acustic octava 3a, statistici Delta Ohm HD2110L

Cod: Delta Ohm HD2110L


 

Brosura produs PDF, 0.83 Mb
           

Descriere

HD 2110L Integrating Sound Level Meter - Portable Analyzer 

The HD2110L is a precision integrating portable sound level meter, with data logging functions, performing both spectrum and statistical analysis. The instrument has been designed in order to offer high-performance analysis of acoustic phenomena. Attention has been paid to the possibility of adjusting the instrument to regulatory modifications and to the necessity of meeting its users’ needs of today and tomorrow. The HD2110L can be integrated with other options to extend its application scope at any time; the firmware can be updated directly by the user by means of the Noise Studio program supplied with the instrument.

 

Technical regulations:

  • Class 1 sound level meter according to IEC 61672-1, 2002 (Certificate of Compliance I.E.N. No. 37035-01C), IEC 60651 and IEC 60804.
  • Class 1 octave and third octave filters according to IEC 61260
  • Microphone in compliance with IEC 61094-4

 

Specifications:

  • Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz,
  • Real-time third octave band with two filters bank: from 16 Hz to 20 kHz and from 14Hz to 18kHz (opt. HD2110.O1)
  • Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s (opt. HD2110.O6).
  • Statistical analysis with calculation of the probability distribution in classes from 1.5dB and of all the percentiles from L1 to L99,
  • Estimate of the audibility of spectral components through comparison with equal loudness curves in real time
  • Simultaneous storage of multi-parameter profiles, reports and records at programmable intervals associated with sound events identified automatically or manually,
  • Measure of the reverberation time by using the method of the interrupted source and with the method of the integration of the response to impulse (opt. HD2110.O4)

 

Applications:

  • Noise monitoring with sound event capture and analysis function,
  • Identification of tonal components even at the standard third octave band,
  • Estimate of the audibility of spectral components through comparison with equal loudness curves in real time,
  • Measurement in workplaces and selection of the individual protection devices (methods SNR, HML and OBM),
  • Sound insulation and reclamation,
  • Production quality control and measurement of machine noise,
  • Architectural acoustic and building measures.

 

 

Alte produse SENSECA

DATALOGGER FOTO-RADIOMETRU LUMINA SOLARA, TEMPERATURA DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

PLUVIOMETRU MASURA CANTITATE SI DEBIT CADERI PRECIPITATII ATMOSFERICE PLOAIE DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

ALBEDOMETRU PIRANOMETRU MASURA ALBEDOU SI RADIATIE GLOBALA INCIDENTA DELTA OHM LPPYRA05

• Albedometer First and Second Class pyranometers according to ISO 9060.
• Complete with: upper and bottom shade disk, desiccant sachet with silica-gel crystals, 2 cartridges, levelling device, support bracket
• calibration report.
• On request 5 or 10m cables with connectors.

 

PH-METRU-CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR DELTA OHM HD2256.2

• Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display,
• to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe,
• it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with
• 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger for pH or mV, conductivity or resistivity or TDS and temperature.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.

 

TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

TERMO-HIGROMETRU PORTABIL DELTA OHM HD2101.1 HD2101.2

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

TERMOMETRU PORTABIL CU 2 CANALE DELTA OHM HD2178.1 HD2178.2

• Thermometer with two inputs, the first for Pt100 probes equipped with SICRAM module, the second input for thermocouple type K, J, T, E, N
• large display
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

TESTER MONITORIZARE SI ANALIZA CALITATE AER INTERIOR, MONOXID, BIOXID DE CARBON DELTA OHM HD37AB1347

• Datalogger for indoor air quality analysis (IAQ)
• measures: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide)
• Memory capacity of 67,600 records for each of the two inputs.
• Logging interval from 15 seconds to 1 hour.

 

CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR CU MASURA REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66

 

LUXMETRU MASURA ILUMINANTA, PAR, IRADIANTA LUMINA SOLARA DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree