Analizor audio sunet Clasa I cu datalogger, analiza spectru acustic octava 3a, statistici Delta Ohm HD2110L

Cod: Delta Ohm HD2110L


 

Brosura produs PDF, 0.83 Mb
           

Descriere

HD 2110L Integrating Sound Level Meter - Portable Analyzer 

The HD2110L is a precision integrating portable sound level meter, with data logging functions, performing both spectrum and statistical analysis. The instrument has been designed in order to offer high-performance analysis of acoustic phenomena. Attention has been paid to the possibility of adjusting the instrument to regulatory modifications and to the necessity of meeting its users’ needs of today and tomorrow. The HD2110L can be integrated with other options to extend its application scope at any time; the firmware can be updated directly by the user by means of the Noise Studio program supplied with the instrument.

 

Technical regulations:

  • Class 1 sound level meter according to IEC 61672-1, 2002 (Certificate of Compliance I.E.N. No. 37035-01C), IEC 60651 and IEC 60804.
  • Class 1 octave and third octave filters according to IEC 61260
  • Microphone in compliance with IEC 61094-4

 

Specifications:

  • Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz,
  • Real-time third octave band with two filters bank: from 16 Hz to 20 kHz and from 14Hz to 18kHz (opt. HD2110.O1)
  • Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s (opt. HD2110.O6).
  • Statistical analysis with calculation of the probability distribution in classes from 1.5dB and of all the percentiles from L1 to L99,
  • Estimate of the audibility of spectral components through comparison with equal loudness curves in real time
  • Simultaneous storage of multi-parameter profiles, reports and records at programmable intervals associated with sound events identified automatically or manually,
  • Measure of the reverberation time by using the method of the interrupted source and with the method of the integration of the response to impulse (opt. HD2110.O4)

 

Applications:

  • Noise monitoring with sound event capture and analysis function,
  • Identification of tonal components even at the standard third octave band,
  • Estimate of the audibility of spectral components through comparison with equal loudness curves in real time,
  • Measurement in workplaces and selection of the individual protection devices (methods SNR, HML and OBM),
  • Sound insulation and reclamation,
  • Production quality control and measurement of machine noise,
  • Architectural acoustic and building measures.

 

 

Alte produse SENSECA

APARAT MASURA SI INREGISTRARE PARAMETRI CO, CO2, PRESIUNE ATMOSFERICA, TEMPERATURA, UMIDITATE DELTA OHM HD21AB HD21AB17

• Carbon Dioxide CO2
• Carbon Monoxide CO
• Atmospheric Pressure
• Temperature
• Relative Humidity
• Dew Point, Wet Bulb Temperature, Absolute Humidity, Mixing Ratio, Enthalpy

 

ANALIZOR AUDIO SUNET CLASA I CU DATALOGGER, ANALIZA SPECTRU ACUSTIC OCTAVA 3A, STATISTICI DELTA OHM HD2110L

• precision integrating portable sound level meter
• data logging function
• performing both spectrum and statistical analysis
• high-performance analysis of acoustic phenomena
• Class 1 sound level meter according to IEC 61672-1, 2002 , IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz
• Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s

 

ANEMOMETRU ULTRASONIC MASURA VITEZA SI DIRECTIE VANT DOUA AXE DELTA OHM HD52.3

• 2 axes ultrasonic Anemometers series HD 52.3D
• Wind speed and direction, U-V Cartesian components of wind speed,
• Relative Humidity and Temperature (option, code "17"),
• Diffuse Solar Radiation (option, code "P"),
• Barometric pressure (option, code "4").

 

PLUVIOMETRU MASURA CANTITATE SI DEBIT CADERI PRECIPITATII ATMOSFERICE PLOAIE DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

ANALIZOR VIBRATII 4-CANALE PROTECTIE VIBRATII MECANICE LOC DE MUNCA DELTA OHM HD2030

• portable vibration analyzer performing spectral and statistical analysis on four channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• satisfies the specifications of standards ISO 8041:2005, ISO 5349-1:2001 (handarm vibrations)
• ISO 2631-1, 2 and 4 1997 (whole-body vibrations)
• detects accelerations on four axes through two accelerometers with integrated amplifying electronics

 

PH-METRU PORTABIL CU TERMOMETRU DELTA OHM HD2305.0

• pHmeter-Thermometer which measures pH, mV and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

PH-METRU TERMOMETRU CU DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

DATALOGGER ANALIZA MONITORIZARE CALITATE MEDIU AER, MONOXID, BIOXID CARBON DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

RADIOMETRU NET CU 4 COMPONENTE MASURA RADIATII SOLARE DELTA OHM LP NET14

• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.
• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?
• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?
• equipped with a temperature sensor (NTC).

 

TESTER MULTIPARAMETRU PH-METRU-CONDUCTIVIMETRU-TERMOMETRU DELTA OHM HD2156.1 HD2156.2

• pHmeter-Conductivity-Thermometer measures pH, mV, conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger, stores the maximum, minimum, average value and can store up to 20,000 sets of three measurements.
• USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.