Brand: Samar

Rezistor de precizie in decade Samar CR-B

Cod: Samar CR-B


 

Brosura produs PDF, 2.15 Mb

Descriere

Power: 0.5 W permanent

Resistances: 0.1W and 1 W to coil, from 10W to 1 MW metal film to 50ppm

Security rule terminals

Plastic box, panel of aluminium with serigraphy

Double insulation

Work frequency: 0 - 500 KHz

Precision: 0.5 %

 

Model

No.

decades

Sections

O

Total Resistance O

CR-B/7DC1

7

10 x ( 1+10+100+1K+10K+100K+1M) O

11.111.110

CR-B/6DC1

6

10 x ( 1+10+100+1K+10K+100K) O

1.111.110

CR-B/6DC2

6

10 x ( 10+100+1K+10K+100K+1M)O

11.111.100

CR-B/5DC1

5

10 x ( 1+10+100+1K+10K) O

111.110

CR-B/5DC2

5

10 x ( 10+100+1K+10K+100K) O

1.111.100

CR-B/5DC3

5

10 x ( 100+1K+10K+100K+1M) O

11.111.000

CR-B/4DC1

4

10 x ( 1+10+100+1K) O

11.110

CR-B/4DC2

4

10 x ( 10+100+1K+10K) O

111.100

CR-B/4DC3

4

10 x ( 100+1K+10K+100K) O

1.111.000

CR-B/4DC4

4

10 x ( 1K+10K+100k+1M) O

11.110.000

CR-B/3DC1

3

10 x ( 1+10+100) O

1.110

CR-B/3DC2

3

10 x ( 10+100+1K) O

11.100

CR-B/3DC3

3

10 x ( 100+1K+10K) O

111.000

CR-B/3DC4

3

10 x ( 1K+10K+100k) O

1.110.000

CR-B/3DC5

3

10 x ( 10K+100K+1M) O

11.100.000

 

 

 

Alte produse SAMAR

CAPACITATE ETALON DE PRECIZIE PENTRU LABORATOR CALIBRARE SAMAR CC

• Values from 1nF to 1µF
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN
• Nominal voltage: 500Vdc
• Temperature coefficient: - (100 ± 50) x 10-6 /°C
• Test voltage: 2,000Vdc
• Insulation resistance: 500,000 MW
• Precision ± 0.1 % at 1,000 Hz, between terminals

 

INDUCTOR STANDARD PENTRU LABORATOARE CALIBRARE SAMAR IC-E50

• Values from 1mH to 1H
• Inductances of precision used as standard in laboratory
• SAMAR certificate of calibration is supplied with each standard inductor.
• Precision: ± 0.5 % at 1,000 Hz, between terminals
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN

 

REFERINTA STANDARD DE TENSIUNE FIXA DE PRECIZIE PENTRU CALIBRARE SAMAR SC51/SC52

• REFERENCES DC VOLTAGE STANDARD
• certificate of calibration of our laboratory
• DC voltage reference standard providing standard cell accuracy for use in measuring laboratories.
• Nominal e.m.f.: 1.01865 calibration 5°/ 6° decimal digits
• Precision: ± 50 µV / ± 25 µV
• max output current: 1 mA continuative
• stability: < 10 ppm/month with working temperature 15 - 25 °C and relative
• humidity 45-85%

 

REZISTENTA ETALON STANDARD DE PRECIZIE UTILIZARE IN AER SAMAR RC-E 50

• On request various values and precision
• Long term stability: ± 50 ppm per year
• Resistances from 0.0001? to 0.1? are 4 terminals, two potential and two current.
• Resistances from 1? to 10M? are wrapped in an ant-inductive way and are two terminals with 2 screws for potential and current
• Included certificate of calibration of our laboratory
• high-accuracy used as standard in laboratory.

 

DECADA CAPACITATI DE PRECIZIE SAMAR CC-B

• certificate of calibration of our laboratory
• DECADES BOXES OF CAPACITY with switch precision 2% at terminals
• Polypropylene capacitor
• Tangd : 0.003 to 1KHz
• Precision: to 1.000Hz at terminals ±2%
• Working voltage: 400Vdc max; 100V switching

 

REZISTENTA ETALON DE INALTA PRECIZIE PENTRU LABORATOR CALIBRARE SI METROLOGIE SAMAR RC80

• On request various values and precision
• Long term stability: +/- 10 ppm per year
• Resistances from 0.0001? to 10? are 4 terminals
• Resistances from 100? to 10M? are two electrolytic copper terminals with 2 screws, one for current and one for voltage
• Included certificate of calibration of our laboratory
• high-accuracy used as standard in laboratory.

 

DECADA INDUCTANTE DE PRECIZIE SAMAR CI

• certificate of calibration of our laboratory
• DECADES BOXES OF INDUCTANCE with switch
• Copper coils wrapped in air Precision to1.000Hz at terminals ±1%
• ON REQUEST BOXES AT VARIOUS SECTIONS AND TO 1 OR 2 DECADES

 

REZISTOR DE PRECIZIE IN DECADE SAMAR CR-B

• Power: 0.5 W permanent
• Resistances: 0.1W and 1 W to coil, from 10W to 1 MW metal film to 50ppm
• Security rule terminals
• Plastic box, panel of aluminium with serigraphy
• Double insulation
• Work frequency: 0 - 500 KHz
• Precision: 0.5 %

 

INDUCTANTA ETALON DE PRECIZIE PENTRU LABORATOR CALIBRARE SAMAR IC

• Values from 1mH to 1H
• Inductances of precision used as standard in laboratory
• SAMAR certificate of calibration is supplied with each standard inductor.
• Precision: ± 0.1 % at 1,000 Hz, between terminals
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN

 

CASETA REZISTENTE IN TREPTE DIVIZOR DE TENSIUNE SI POTENTIAL SAMAR CRC/1

• Used as a potential divider or for calibration (for example insulation tester)
• Chemical resistances of high stability, with dissipation 1W
• Precision 1% dc and ac up to 1 MHz. (on request execution at 0.1% )
• Range: 0 to 500M? with terminals for the following values:
• 0.5 - 1 - 2 - 3 - 4 - 5 - 10 - 20 -30 - 40 - 50 - 100 - 200 - 300 - 400 - 500 K?
• 1 - 2 - 3 - 4 - 5 - 10 - 20 -30 - 40 - 50 - 100 - 200 - 300 - 400 - 500 M?
• Execution in reading-desk metal case.