Brand: Samar

Rezistor Etalon standard rezistente mari si inalta tensiune Samar RC80/M

Cod: Samar RC80/M


 

Brosura produs PDF, 1.04 Mb

Descriere

  • On request various values and precision
  • Nominal Values: 10MO..100TO
  • Nominal Voltage 500V
  • Included certificate of calibration of our laboratory

 

 

 

Type

Nominal Value

MO

Tolerance

at 20 °C, %

RC80/M2

10

± 1

RC80/M3

100

± 1

RC80/M4

1.000

± 1

RC80/M5

10.000

± 1

RC80/M6

100.000

± 1

RC80/M7

1.000.000

± 5

RC80/M8

10.000.000

± 5

RC80/M9

100.000.000

± 10

 

Alte produse SAMAR

PUNTE DE MASURA WHEATSTONE THOMSON MAXWELL DE SAUTY SCHERING

• DC / AC BRIDGES
• THOMSON - WHEATSTONE BRIDGE
• MAXWELL - DE SAUTY BRIDGE 50Hz
• SCHERING BRIDGE

 

DECADA INDUCTANTE DE PRECIZIE SAMAR CI

• certificate of calibration of our laboratory
• DECADES BOXES OF INDUCTANCE with switch
• Copper coils wrapped in air Precision to1.000Hz at terminals ±1%
• ON REQUEST BOXES AT VARIOUS SECTIONS AND TO 1 OR 2 DECADES

 

BOXA DECADICA REZISTENTA DE PRECIZIE SAMAR CR

• DECADES BOXES OF RESISTANCE with switch precision 0.05% at terminals
• Calibration precision: ± 0.02 %
• Thanks to an opportune seasoning process the long term stability is ensured: 10 ppm in the first year and max 20 ppm in three years.
• Switches have a resistance of contact lower than 0.001 W invariable in the time.
• certificate of calibration of our laboratory

 

INDUCTANTA ETALON DE PRECIZIE PENTRU LABORATOR CALIBRARE SAMAR IC

• Values from 1mH to 1H
• Inductances of precision used as standard in laboratory
• SAMAR certificate of calibration is supplied with each standard inductor.
• Precision: ± 0.1 % at 1,000 Hz, between terminals
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN

 

CASETA REZISTENTE IN TREPTE DIVIZOR DE TENSIUNE SI POTENTIAL SAMAR CRC/1

• Used as a potential divider or for calibration (for example insulation tester)
• Chemical resistances of high stability, with dissipation 1W
• Precision 1% dc and ac up to 1 MHz. (on request execution at 0.1% )
• Range: 0 to 500M? with terminals for the following values:
• 0.5 - 1 - 2 - 3 - 4 - 5 - 10 - 20 -30 - 40 - 50 - 100 - 200 - 300 - 400 - 500 K?
• 1 - 2 - 3 - 4 - 5 - 10 - 20 -30 - 40 - 50 - 100 - 200 - 300 - 400 - 500 M?
• Execution in reading-desk metal case.

 

REZISTOR ETALON STANDARD REZISTENTE MARI SI INALTA TENSIUNE SAMAR RC80/M

• On request various values and precision
• Nominal Values: 10MO..100TO
• Nominal Voltage 500V
• Included certificate of calibration of our laboratory

 

REZISTOR DE PRECIZIE IN DECADE SAMAR CR-B

• Power: 0.5 W permanent
• Resistances: 0.1W and 1 W to coil, from 10W to 1 MW metal film to 50ppm
• Security rule terminals
• Plastic box, panel of aluminium with serigraphy
• Double insulation
• Work frequency: 0 - 500 KHz
• Precision: 0.5 %

 

CASETA REZISTOARE IN TREPTE REZISTENTE MARI SI INALTA TENSIUNE 5KV SAMAR CRC/4

• Decade box with spires
• studied to simulate high resistance
• suitable to check the insulation testers with test voltage up to 5000V d.c.
• Ranges that can be made with the 4 contact spires supplied: 10x1 M?, 10x10M?, 10x100M?, 10x1G?.
• Temperature coefficient: 100 ppm °C .
• Max power 2W for each element.
• Applicable max voltages : 1250V with 1M?, 2500V with 2M?, 3750V with 3M? and 5000V for values higher than 3M?.

 

REZISTENTA ETALON DE INALTA PRECIZIE PENTRU LABORATOR CALIBRARE SI METROLOGIE SAMAR RC80

• On request various values and precision
• Long term stability: +/- 10 ppm per year
• Resistances from 0.0001? to 10? are 4 terminals
• Resistances from 100? to 10M? are two electrolytic copper terminals with 2 screws, one for current and one for voltage
• Included certificate of calibration of our laboratory
• high-accuracy used as standard in laboratory.

 

REZISTENTA ETALON STANDARD DE PRECIZIE UTILIZARE IN AER SAMAR RC-E 50

• On request various values and precision
• Long term stability: ± 50 ppm per year
• Resistances from 0.0001? to 0.1? are 4 terminals, two potential and two current.
• Resistances from 1? to 10M? are wrapped in an ant-inductive way and are two terminals with 2 screws for potential and current
• Included certificate of calibration of our laboratory
• high-accuracy used as standard in laboratory.