Brand: Samar

Inductor standard pentru laboratoare calibrare Samar IC-E50

Cod: Samar IC-E50


 

Brosura produs PDF, 0.85 Mb

Descriere

  • Values from 1mH to 1H
  • Inductances of precision used as standard in laboratory
  • SAMAR certificate of calibration is supplied with each standard inductor.
  • Precision: ± 0.5 % at 1,000 Hz, between terminals
  • ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN

 

 

Model

Nominal Value H

DC Resistance O

Q

to 100 Hz

Max Current

A

IC - E 50/1

1

530

1,18

0,06

IC - E 50/2

0,1

43

1,46

0,25

IC - E 50/3

0,01

4,6

1,36

0,7

IC - E 50/4

0,001

0,53

1,18

1,5

 

 

 

 

 

 

 

 

 

 

Model

Nominal Value H

DC Resistance O

Max Current

A

M/1

1

340

0,2

M/2

0,1

24

0,4

M/3

0,01

4

1

M/4

0,001

1

1,2

 

Alte produse SAMAR

DECADA INDUCTANTE DE PRECIZIE SAMAR CI

• certificate of calibration of our laboratory
• DECADES BOXES OF INDUCTANCE with switch
• Copper coils wrapped in air Precision to1.000Hz at terminals ±1%
• ON REQUEST BOXES AT VARIOUS SECTIONS AND TO 1 OR 2 DECADES

 

REZISTOR DE PRECIZIE IN DECADE SAMAR CR-B

• Power: 0.5 W permanent
• Resistances: 0.1W and 1 W to coil, from 10W to 1 MW metal film to 50ppm
• Security rule terminals
• Plastic box, panel of aluminium with serigraphy
• Double insulation
• Work frequency: 0 - 500 KHz
• Precision: 0.5 %

 

BOXA DECADICA REZISTENTA DE PRECIZIE SAMAR CR

• DECADES BOXES OF RESISTANCE with switch precision 0.05% at terminals
• Calibration precision: ± 0.02 %
• Thanks to an opportune seasoning process the long term stability is ensured: 10 ppm in the first year and max 20 ppm in three years.
• Switches have a resistance of contact lower than 0.001 W invariable in the time.
• certificate of calibration of our laboratory

 

CASETA REZISTENTE IN TREPTE DIVIZOR DE TENSIUNE SI POTENTIAL SAMAR CRC/1

• Used as a potential divider or for calibration (for example insulation tester)
• Chemical resistances of high stability, with dissipation 1W
• Precision 1% dc and ac up to 1 MHz. (on request execution at 0.1% )
• Range: 0 to 500M? with terminals for the following values:
• 0.5 - 1 - 2 - 3 - 4 - 5 - 10 - 20 -30 - 40 - 50 - 100 - 200 - 300 - 400 - 500 K?
• 1 - 2 - 3 - 4 - 5 - 10 - 20 -30 - 40 - 50 - 100 - 200 - 300 - 400 - 500 M?
• Execution in reading-desk metal case.

 

PUNTE DE MASURA WHEATSTONE THOMSON MAXWELL DE SAUTY SCHERING

• DC / AC BRIDGES
• THOMSON - WHEATSTONE BRIDGE
• MAXWELL - DE SAUTY BRIDGE 50Hz
• SCHERING BRIDGE

 

INDUCTOR STANDARD PENTRU LABORATOARE CALIBRARE SAMAR IC-E50

• Values from 1mH to 1H
• Inductances of precision used as standard in laboratory
• SAMAR certificate of calibration is supplied with each standard inductor.
• Precision: ± 0.5 % at 1,000 Hz, between terminals
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN

 

DECADA REZISTENTE DE PRECIZIE SAMAR CR-E

• DECADES BOXES OF RESISTANCE with switch precision 0.1% at terminals
• Calibration precision: ± 0.02 %
• The precision shown refers to the terminals and therefore is total resistance included the resistance of zero
• Resistors are in manganine wire (temperature coefficient ± 10 ppm/°C) wrapped in ant-inductive way.
• Thanks to an opportune seasoning process the long term stability is ensured: : 10 ppm in the first year and max. 20 ppm in three years

 

CAPACITOR STANDARD DE VALOARE FIXA SAMAR CC-E50

• Values from 1nF to 1µF
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN
• Nominal voltage : 500Vdc
• Temperature coefficient: - (100 ± 50) x 10-6 /°C
• Test voltage: 2,000Vdc
• Insulation resistance: 500,000 MW
• Precision: ± 0.5 % at 1,000 Hz, between terminals

 

REZISTOR ETALON STANDARD REZISTENTE MARI SI INALTA TENSIUNE SAMAR RC80/M

• On request various values and precision
• Nominal Values: 10MO..100TO
• Nominal Voltage 500V
• Included certificate of calibration of our laboratory

 

INDUCTANTA ETALON DE PRECIZIE PENTRU LABORATOR CALIBRARE SAMAR IC

• Values from 1mH to 1H
• Inductances of precision used as standard in laboratory
• SAMAR certificate of calibration is supplied with each standard inductor.
• Precision: ± 0.1 % at 1,000 Hz, between terminals