The MJ½LNER Series is designed to measure the resistance of circuit breaker contacts, bus-bar joints, contact elements in bus-bars and other high-current links. This product has been designed with safety, ease of use and versatility in mind. It can be used anywhere to measure a low resistance value with high accuracy. It conducts true DC ripple free current testing of bus bars, circuit breakers, fuses, etc.

 

Features:

  • Specifically designed for measuring contact resistances in circuit breakers, disconnecting switches, bus-bar joints, and other such devices
  • Safer testing using the patented DualGroundş technology to test circuit breakers with both sides grounded
  • Fully automatic testing- microprocessor controlled
  • Wide measuring range and test currents
  • High powered and light
 

Alte produse MEGGER

ANALIZOR CIRCUITE INTRERUPATOARE MEGGER TM1700

• Provides reliable and accurate test results in noisy high voltage substations
• Four standard models. Full stand-alone functionality or data acquisition models without user interface.
• Fast and safer with DualGround™ testing, both sides of breaker grounded
• On-screen assistance with connection diagrams and test template Wizard
• All models can be controlled via computer

 

TRMS CLAMP METER MEGGER - DCM1500

• DC and AC current up to 1500 A
• True RMS measurement for greater accuracy
• Large jaw size safely assists with uninsulated conductor measurements
• 750 Vac and 1000 Vdc

 

MICROOHMETRU 600A MEGGER DLRO600

• Small and weighs less than 33 lbs (15 kg)
• Test currents from 10 A to 600 A dc
• 0.1 µohms best resolution
• On board memory for up to 300 test results and notes
• RS232 port to download stored results or for real time output to a printer
• Supplied complete with 16.4 ft (5 m) test leads and download software

 

MEGOHMETRU IZOLATIE 15000V 15KV MEGGER S1-1568/2

• Rezultate fiabile în substaţii zgomotoase
• Teste precise cu RE>Act™
• Control de la distanţă pentru testare mai sigură şi mai ușoară
• PI Predictor™ reduce timpul de testare la jumătate
• Suită completă de diagnosticare cu capacitate PDC

 

REFLECTOMETRU LOCALIZARE DEFECTE CABLU MEGGER TDR1000/3P

• TDR1000/3P is suitable for use on both dead or live cables
• Simple operation
• AUTO set up for instant use
• Ultra fast pulse for near end fault identification
• Trace HOLD feature to allow comparison between cables
• IP54 rating offers real life working
• No blocking filters require
• Supplied with fused test leads

 

HIGHLY PORTABLE MICRO-OHMMETER WITH DUALGROUND SAFETY MEGGER - DLRO100E, DLRO100X AND DLRO100H

• CAT IV 600 V for safe operation
• Light, 100 A, battery powered unit for portability
• High noise immunity for stable readings
• Smooth DC output for circuit breaker testing

 

APARAT MASURA PRIZE DE PAMANT MEGGER DET4T2

• 2, 3 and 4 point testing
• Stakeless (clamp-on) testing capability
• ART (Attached Rod Technique) capability
• Multiple, user selectable test frequencies
• Resistance measurement range to 200 kO
• IP54 rated
• Warning indicators prevent test failure
• Simple one button operation
• Included leads, stakes, calibration certificate and rugged carry case

 

KARL FISCHER MOISTURE IN OIL TEST SETS MEGGER ½ KF875 AND KF-LAB MKII

• Coulometric Karl Fischer titrimetry
• KF875 optimized for insulating oil with an SG of 0.875, completely portable
• KF-LAB MkII offers greater flexibility, versatility and sample data input than the KF875; also completely portable
• KF-LAB MkII analyzes materials with an SG between 0.6 & 1.4, plus insulating oils with an SG of 0.875

 

BATTERY IMPEDANCE TESTER MEGGER - BITE2 AND BITE2P

• Determines condition of lead-acid and NiCd cells up to 7000 Ah
• On-board Pass/Warning/Fail indications
• Robust, repeatable instruments
• On-line testing

 

TRUSA MASURA TANGENTA UNGHI DE PIERDERI TANGETA DELTA MEGGER DELTA4310

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression