Descriere
Augmenting Megger Ducter range of 10 A micro-ohmmeters, the DLRO10HDX combines ultimate simplicity of operation with a rugged IP65 case designed for stable ground and bench operation and provides memory storage.
These units are powered from either rechargeable battery or mains power making it suitable for continuous testing in production line/repetitive use environments.
Rotary switch controls are simple and easy to operate in all weather conditions and with gloved hands. A large, clear, backlit LCD display is easy to read from a distance. The DLRO10HDX provides significantly enhanced compliance and is capable of delivering 10 A into measurements up to 250 mOhm and 1 A into measurements up to 2.5 Ohm. The duration of each test may be up to 60 seconds.
The DLRO10HDX is rated CAT III 300 V provided the optional terminal cover is fitted to the instrument.
History of Ducter testing
For over 100 years the Ducter test has been used to describe a simple test for measuring very low contact resistances and Ducter, which is still used as a trade mark, was the name originally given to the low resistance ohmmeter manufactured by Megger. The name Ducter was registered by Megger in June 1908 and Ducter has since become the industry standard.
Features:
Alte produse MEGGER
|
UNIVERSAL CIRCUIT BREAKER TEST SETS MEGGER PS-9130 AND PS-9160
• Proven power train
|
|
AUTOMATIC OIL CIRCUIT RECLOSER TESTER MEGGER OCR8015/9150
• Preprogrammed test sequences for reclosers and sectionalizers
|
|
TRUSA TRIFAZATA DE VERIFICARE RELEE DE PROTECTIE MEGGER SVERKER900
• The toolbox for substation 3-phase testing |
|
ANALIZOR RASPUNS IN FRECVENTA TRANSFORMATOARE DE PUTERE MEGGER FRAX
• Frequency range 0.1 Hz - 25 MHz, user selectable |
|
TRUSA MASURA TANGENTA UNGHI DE PIERDERI TANGETA DELTA MEGGER DELTA4310
• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set |
|
TRUSA CURENT-TENSIUNE VERIFICAREA RELEELOR DE PROTECTIE MEGGER SMRT410
• Small, rugged, lightweight and powerful |
|
TESTER UNIVERSAL ELECTRICIAN INSTALATII MEGGER MFT1800 MFT1825 MFT1815
• Testarea RCD de tip B şi a RCD trifazate pentru aplicaţii industriale fără împământare
|
|
TESTER BATERII ACUMULATORI MEGGER BITE5
• Măsoară impedanța pe celule de până la 200 V
|
|
LOCATOR SCURGERI LA PAMANT CURENTI DC IN SISTEME BATERII MEGGER BGFT 246100B
• Ground faults in ungrounded dc battery systems easily located |
|
TESTER PORTABIL RAPORT TRANSFORMARE LA TRANFORMATOARE MEGGER TTRU1
• Raport de transformare, curent de excitație și polaritate
|