Cod: ETS-Lindgren 95236-1/ 95242-1
Descriere
The probe's operating frequency range is 10 kHz to 100 MHz. This probe is most efficient from about 15 kHz to 4 MHz. The 95236-1 probe cover the low frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (10 kHz · Z MHz).
The Model 95236-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter, exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
10 kHz |
|
Frequency Maximum |
100 MHz |
|
Maximum Power |
100 W |
It enables testing to be performed which previously required the use of two separate injection probes, the ERA type 36A and 37A This is our most efficient injection device from 4 MHz to almost 600 MHz The 95242-1 probe covers the high frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (5 MHz - 400 MHz). This injection probe is also suitable for injecting the required current waveforms of MIL-STD-461D limits CS115 and CS116 (for CS116, one of our lower frequency probes is required as well). Testing to British Defense Standard DEF STA 59-41, Part 3 is also supported by this model. When necessary, our 95235-1 injection probe has larger 2.625" window diameter, but is less efficient than the 95242-1. When calibrating the Calibration Jig coupled current vs. forward power into the injection probe, the combination of 95242-1 probe and 95241-1 Jig has an excellent low VSWR.
The Model 95242-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
2 MHz |
|
Frequency Maximum |
400 MHz |
|
Maximum Power |
100 W |
Alte produse ETS-LINDGREN
|
SONDE MASURA CAMP ELECTRIC 500 KHZ..5 GHZ ETS-LINDGREN HI-4433
• Frequency Range: 500kHz - 5GHz |
|
TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE MONITOARE VIDEO SI TERMINALE CU DISPLAY ETS-LINDGREN HI-3603
• VDT / VLF Survey Instrument |
|
ANTENA BUCLA PASIVA DE TESTAT ECRANARE SI IMUNITATE RADIATII 20 HZ..5 MHZ ETS-LINDGREN 6511
• Frequency Minimum 20 Hz |
|
ANTENA DIPOL REZONANT 30 MHZ..1 GHZ ETS-LINDGREN 3121D
• Frequency Minimum 30 MHz |
|
ANTENA BICONICA TESTARE IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109
• Frequency Minimum 20 MHz |
|
ANTENA DIPOL DE PRECIZIE CU EMISIE OMNIDIRECTIONALA TEST IMUNITATE ELECTROMAGNETICA 440..3010 MHZ ETS-LINDGREN 3125
• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz |
|
ANTENA HORN LINIAR POLARIZATA OCTAVA 1..8 GHZ ETS-LINDGREN 3161
• Frequency Minimum 1 GHz |
|
CAMERA DE TEST IZOLATA RF MASURATORI EMC SI ECRANARE ETS-LINDGREN 5230
• Standard dimenssions 600 x 500 x 500 mm |
|
ANTENA BUCLA MAGNETICA ECRANATA FRECVENTA JOASA 30 HZ..100 KHZ ETS-LINDGREN 7605/ 7606
• Frequency Minimum 30 Hz |
|
ANTENA HORN GHID DE UNDA DUBLU CREASTA 200 MHZ..2.5 GHZ ETS-LINDGREN 3106B
• Frequency Minimum 200 MHz |