Filtre EMI de putere retele monofazate aplicatii Tempest/ EMC 32..120A ETS-Lindgren N192X

Cod: ETS-Lindgren N192X


 

Brosura produs PDF, 1.02 Mb

Descriere

  • Current Range 32 to 250 Amperes
  • Very High RF Attenuation
  • Fully Tested for Attenuation Performance
  • Durable Construction
  • CE Marked

 

APPLICATIONS

  • In high performance screened rooms, providing sufficient attenuation of both the incoming and outgoing mains supply lines to match the shield performance.
  • In TEMPEST applications where the very highest degree of protection is required to obtain maximum security.
  • In EMP protection systems.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Freq. (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz Sys. Per Line (Max)

DC Resistance Per Line (milliohms)

N1923

32

250

DC/50/60

Single

0.6

24

N1923

20

120

400

Single

0.6

24

N1924

63

250

DC/50/60

Single

0.7

9

N1924

40

120

400

Single

0.7

9

N1925

100

250

DC/50/60

Single

0.9

5

N1925

60

120

400

Single

0.9

5

N1926

200

250

DC/50/60

Single

0.9

2.5

N1926

120

120

400

Single

0.9

2.5

N1926/250

250

250

DC/50/60

Single

0.9

2.5

N1926/250

120

120

400

Single

0.9

2.5

 

Alte produse ETS-LINDGREN

TESTER CAMP MAGNETIC 30..2000 HZ ETS-LINDGREN HI-3624

• Isotropic Response
• True RMS Detection
• 100dB Dynamic Range
• Low Cost, True RMS Magnetic Field Measurements

 

ANTENA HORN GHID DE UNDA DUBLU CREASTA 200 MHZ..2.5 GHZ ETS-LINDGREN 3106B

• Frequency Minimum 200 MHz
• Frequency Maximum 2.5 GHz
• Connectors Type N (f)
• Impedance (Nominal) 1600 W
• Maximum Continuous Power 800 W
• Pattern Type directional

 

ANTENA DE BANDA LARGA BICONICA 30 MHZ..1 GHZ ETS-LINDGREN 3180

• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

TESTER MASURA ATENUARE RF SI ECRANARE ELECTROMAGNETICA 8..64 MHZ ETS-LINDGREN MF-130D

• Measurement frequencies: 8 MHz, 16 MHz, 32 MHz and 64 MHz
• Makes Shielding Attenuation
• MIL-STD-285 Measurements
• NSA 65-6 Measurements
• IEEE STD-299 Measurements
• EN 50147-1 Measurements
• Stores/Downloads up to 63
• Includes Windows® Compatible Easy-To-Use, Portable Software

 

FILTRE RFI/ EMI CONTROL LINIE PENTRU SISTEME ALARMA, DETECTIE SI MONITORIZARE ETS-LINDGREN N296X/ N2972

• Tubular, flat-pack or modular design
• Attenuation from 100dB at 10kHz
• Suitable for EMI, EMP and Tempest protection
• 24V DC and 250V AC/DC options

 

ANTENA BUCLA PASIVA TESTARE ECRANARE SI IMUNITATE RADIATII 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

INTERFATA WIRELESS TESTARE TELEFOANE MOBILE IN COMUNICATII CELULARE ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz

 

TESTER EMF CAMP ELECTRIC & MAGNETIC RF CONFORM CU STANDARDE INDUSTRIALE 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

ANTENA HORN GHID DE UNDE PENTRU MASURATORI EMC 400 MHZ..6 GHZ ETS-LINDGREN 3119

• Frequency Minimum 400 MHz
• Frequency Maximum 6 GHz
• VSWR Ratio (AVG) 3.5:1 max
• <2:1 above 500 MHz
• Maximum Continuous Power 1500 W @ 400 MHz, 800 W @ 6 GHz