Celula GTEM test, masura, incercari emisii radiatii electromagnetice si imunitate EMC ETS-Lindgren 5407

Cod: ETS-Lindgren 5407


 

Brosura produs PDF, 0.13 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f £1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

200 (500 W with optional blower) W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq £1.50:1
Characteristic Freq
£1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Two AC receptacles
  • ETS-Lindgren absorber material
  • Customer will need to provide manpower and specific tools
  • Three N-type connectors
  • One fiber optic penetration
  • Individually characterized with results of TDR and VSWR tests
  • Manual emissions correlation software (on request)
  • 5400 GTEM! Series manual
  • Shipped disassembled
  • Working supervisor for installation is provided. (Outside North America, call factory)
  • 7/16" DIN to type "N" adaptor
  • Primary door 27" W x 29.1" H clear opening (68.6 cm x 74.7 cm)
  • Mobile base with locking casters
  • One 20 amp, 2 line filter
 

Optiuni recomandate

  • Blank panel with frame
  • Illumination assembly
  • Manual EUT manipulator
  • Panel with connectors and frame
  • Shielded Window for primary door
  • Blank panel
  • Blank panel with connectors
  • Blower assembly
  • Three Position Ortho-Axis Pneumatic Manipulator (light duty)
 

Alte produse ETS-LINDGREN

ANTENA LOG-PERIODICA LINIAR POLARIZATA DE MARE PUTERE 200..1 GHZ ETS-LINDGREN 3152

• Frequency Minimum 200 MHz
• Frequency Maximum 1000 MHz
• Input Impedance 50 ?
• SWR 1.5:1 average, 2:1 maximum
• Maximum RF input power 1 kW
• RF Connector N Type
• Pneumatically Driven Polarization
• Ideal for Immunity Testing Per 2004/144/EC and ISO-11451-2

 

ANTENA DIPOL REZONANT 30 MHZ..1 GHZ ETS-LINDGREN 3121D

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50W-260W
• Pattern Type omnidirectional
• Polarization linear

 

FILTRU PUTERE APLICATII TEMPEST/ EMP DE MARE PERFORMANTA CURENTI 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

ANTENA LOG-PERIODICA POLARITATE LINIARA 100 MHZ..1 GHZ ETS-LINDGREN 3150

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors 7/8 EIA Flange (others available)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type directional
• Polarization linear

 

TESTER CURENT RF INDUS 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

ANTENA BUCLA PASIVA TESTARE ECRANARE SI IMUNITATE RADIATII 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

GENERATOR CAMP ELECTRIC ORIZONTAL/ VERTICAL 10 KHZ..30 MHZ ETS-LINDGREN 5502

• Generates vertical or horizontal electric field
• Generates Fields 200 v/m in the 10 kHz to 30 MHz Frequency Range
• Fully Adjustable Height and Separation of Main Conductors
• Large Immunity Volume
• Chamber Supported

 

SONDE MASURA CAMP ELECTRIC 500 KHZ..5 GHZ ETS-LINDGREN HI-4433

• Frequency Range: 500kHz - 5GHz
• Automatic Continuous Zeroing
• Fiber Optic Technology
• Dynamic Range down to 300 mA/m
• Data from each axis can be viewed individually

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

FILTRE RFI/ EMI CONTROL LINIE PENTRU SISTEME ALARMA, DETECTIE SI MONITORIZARE ETS-LINDGREN N296X/ N2972

• Tubular, flat-pack or modular design
• Attenuation from 100dB at 10kHz
• Suitable for EMI, EMP and Tempest protection
• 24V DC and 250V AC/DC options