Celula GTEM test, masura, incercari emisii radiatii electromagnetice si imunitate EMC ETS-Lindgren 5407

Cod: ETS-Lindgren 5407


 

Brosura produs PDF, 0.13 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f £1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

200 (500 W with optional blower) W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq £1.50:1
Characteristic Freq
£1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Two AC receptacles
  • ETS-Lindgren absorber material
  • Customer will need to provide manpower and specific tools
  • Three N-type connectors
  • One fiber optic penetration
  • Individually characterized with results of TDR and VSWR tests
  • Manual emissions correlation software (on request)
  • 5400 GTEM! Series manual
  • Shipped disassembled
  • Working supervisor for installation is provided. (Outside North America, call factory)
  • 7/16" DIN to type "N" adaptor
  • Primary door 27" W x 29.1" H clear opening (68.6 cm x 74.7 cm)
  • Mobile base with locking casters
  • One 20 amp, 2 line filter
 

Optiuni recomandate

  • Blank panel with frame
  • Illumination assembly
  • Manual EUT manipulator
  • Panel with connectors and frame
  • Shielded Window for primary door
  • Blank panel
  • Blank panel with connectors
  • Blower assembly
  • Three Position Ortho-Axis Pneumatic Manipulator (light duty)
 

Alte produse ETS-LINDGREN

ANTENA SPIRALA CONICA LOGARITMICA 200 MHZ..1 GHZ ETS-LINDGREN 3101

• Frequency Minimum 200 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 150 W
• Polarization circular
• VSWR 2.4:1
• Extremely low VSWR
• Individually calibrated

 

FILTRE EMI DE PUTERE RETELE MONOFAZATE APLICATII TEMPEST/ EMC 32..120A ETS-LINDGREN N192X

• Current Range 32 to 250 Amperes
• Very High RF Attenuation
• Fully Tested for Attenuation Performance
• Durable Construction
• CE Marked

 

CAMERA DE TEST IZOLATA RF MASURATORI EMC SI ECRANARE ETS-LINDGREN 5230

• Standard dimenssions 600 x 500 x 500 mm
• Progressive Latching
• Large Working Interior
• Up to 120 dB RF Isolation

 

ANTENA DE BANDA LARGA OMNIDIRECTIONALA 1..18 GHZ ETS-LINDGREN 3183

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1GHz, 25 watts @ 18 GHz
• Chamber Characterization
• Broadband Spectrum Monitoring

 

TESTER EMF CAMP ELECTRIC & MAGNETIC RF CONFORM CU STANDARDE INDUSTRIALE 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

FILTRE PROTECTIE RETEA MONOFAZATA APLICATII RFI/EMI PUTERE & CURENT INALT 400..800A ETS-LINDGREN N2510

• >3000 Amp capability
• Fully accessible end chambers
• 80 dB Insertion Loss From 100 kHz to 10 GHz
• Excellent strength to weight ratio
• RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
• High current capability
• Compact design

 

ANTENA HORN PIRAMIDAL CU GENERARE CAMP ELECTRIC TESTARE EMC AUTO GMW 3097 SI ES-XW7T-1A278-AC 1.2..1.4 GHZ ETS-LINDGREN 3162-01

• Frequency Minimum 1.2 GHz
• Frequency Maximum 1.4 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 550 W
• Pattern Type directional
• GMW 3097
• ES-XW7T-1A278-AC

 

ANTENA BICONICA TESTARE IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA BUCLA PASIVA DE TESTAT ECRANARE SI IMUNITATE RADIATII 20 HZ..5 MHZ ETS-LINDGREN 6511

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear