Generator camp electric Orizontal/ Vertical 10 kHz..30 MHz ETS-Lindgren 5502

Cod: ETS-Lindgren 5502


 

Brosura produs PDF, 0.83 Mb

Descriere

  • Generates vertical or horizontal electric field
  • Generates Fields 200 v/m in the 10 kHz to 30 MHz Frequency Range
  • Fully Adjustable Height and Separation of Main Conductors
  • Large Immunity Volume
  • Chamber Supported

 

Electrical Specifications

Frequency

E Mode: 10 kHz - 30 MHz
H Mode: 100 kHz - 300 MHz

Input Impedance

50 ?

Max RF Input Power

10 kW

RF Connector

1-5/8" EIA

VSWR

2:1 typical

 

Applications

  • ISO-11451-2
  • SAE J551/11
  • MIL-STD 461
 

Accesorii standard

  • 6 m (19.7 ft) long Conducting Elements with Retracting Wire Bundles
  • Support frame assembly
  • Motorized Winch and Pulley Assembly
  • RF Load with Ground Connections
  • RF Feed Box with Ground Connections
  • Waveguide Feed-thru Penetrations for the Chamber Ceiling
  • Ground Connection Sockets for the Chamber Floor
 

Optiuni recomandate

  • Automation of Balun Box Switches
  • Height/separation Control Connection Outside of the Chamber
  • 8 m (26.2 ft) long Elements
 

Alte produse ETS-LINDGREN

FILTRE PUTERE TEMPEST/ EMI/ EMC DE MARE PERFORMANTA CURENTI 16..200A ETS-LINDGREN N500X

• Low power dissipation
• Compact Rugged Construction
• 100dB insertion loss from 40kHz
• Suitable for 400Hz supplies
• Current Range 16 to 200 Amperes

 

ANTENA HIBRID LOG-PERIODICA DE BANDA LARGA PENTRU MASURATORI EMC 26 MHZ..6 GHZ ETS-LINDGREN 3142D

• Frequency Range 26 MHz - 60 MHz, 60 MHz - 600 MHz, 600 MHz - 1 GHz, 1 GHz - 6 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 500 W, 1 kW, 500 W, 200 W
• VSWR 2.0:1

 

FILTRE RFI/ EMI CONTROL LINIE PENTRU SISTEME ALARMA, DETECTIE SI MONITORIZARE ETS-LINDGREN N296X/ N2972

• Tubular, flat-pack or modular design
• Attenuation from 100dB at 10kHz
• Suitable for EMI, EMP and Tempest protection
• 24V DC and 250V AC/DC options

 

FILTRE PROTECTIE TEMPEST/ RFI/ EMI PENTRU TELECOMUNICATII ETS-LINDGREN N24X/ N29X

• Suitable for EMI, EMP and Tempest protection
• Tubular, flat-pack or modular design
• 100dB insertion loss
• New ISDN filters now available
• Matched to balanced 600 Ohm lines

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE LINII TRANSMISIE RETELE ENERGIE ELECTRICA ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA LOG-PERIODICA DIRECTIONALA MASURATORI CISPR 16-1 BANDA 200 MHZ..2 GHZ ETS-LINDGREN 3148B

• Frequency Minimum 200 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear

 

ANTENA HORN GHID DE UNDA DUBLU CRESTATA 100 MHZ..1 GHZ ETS-LINDGREN 3112

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 800 W
• Maximum Power 2 kW

 

FILTRE PROTECTIE EVENIMENTE TRANZITORII RETEA TRIFAZATA APLICATII RFI/EMP PUTERE & CURENT INALT 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

SONDA MASURA CAMP MAGNETIC 300 KHZ..300 MHZ ETS-LINDGREN HI-4433

• Frequency Range: 300 kHz - 300 MHz
• Magnetic Field Sensing: 5-300 MHz
• Automatic Continuous Zeroing
• Data from each axis can be viewed individually
• Isotropic Detection