Filtru putere aplicatii Tempest/ EMP de mare performanta curenti 16..200A ETS-Lindgren N600X

Cod: ETS-Lindgren N600X


 

Brosura produs PDF, 0.64 Mb

Descriere

  • Suitable for 400Hz supplies
  • Compact Rugged Construction
  • Maximum Protection for EMP and Tempest applications
  • Current Range 16 to 200 Amperes
  • 100 dB Insertion Loss from 14 kHz to 40 GHz
  • Low power dissipation

 

APPLICATIONS

  • In high performance screened rooms and anechoic chambers the N600X series provides protection of both incoming and outgoing supplies in line with the shield performance.
  • In TEMPEST applications, the N600X filters provide an extremely high degree of protection required to obtain maximum security.
  • N600X filters are ideal for EMP applications needing to meet the most stringent NATO requirements.
  • N600X filters can be used for filtering of mains incomers entering screened room facilities.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Frequency (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz System Per Line (Max)

Full Load Dissipation (W)

6000

16

250

DC/50/60/400

2

1.2

35

6001

16

440/250

DC/50/60/400

4

1

45

6002

32

250

DC/50/60/400

2

1.1

70

6003

32

440/250

DC/50/60/400

4

0.75

50

6004

63

250

DC/50/60/400

2

1.3

68

6005

63

440/250

DC/50/60/400

4

0.75

155

6006

100

250

DC/50/60/400

2

0.7

135

6007

100

440/250

DC/50/60/400

4

0.5

135

6009

200

440/250

DC/50/60/400

4

1

400

 

Alte produse ETS-LINDGREN

ANTENA LOG-PERIODICA POLARITATE LINIARA DUBLA 100 MHZ..1.1 GHZ ETS-LINDGREN 3145BDP

• Frequency Range 100 MHz - 1.1 GHz
• Input Impedance 50 ?
• VSWR 1.5:1 average, 3.5:1 maximum
• Maximum RF input power 800 W
• Stainless Steel Construction
• Dual Linearly Polarized

 

BOBINA HELMHOLTZ MONOAXIALA GENERARE CAMP MAGNETIC UNIFORM FRECVENTE JOASE ETS-LINDGREN 6400

• Excellent for Magnetic Immunity Testing
• A Source for Calibration
• Custom Models Available

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA HORN PIRAMIDAL CU GENERARE CAMP ELECTRIC TESTARE EMC AUTO ES-XW7T-1A278-AC 2.7..3.1 GHZ ETS-LINDGREN 3162-02

• Frequency Minimum 2.7 GHz
• Frequency Maximum 3.1 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Pattern Type directional
• Polarization linear
• Meets Specs for ES-XW7T-1A278-AC

 

ANTENA HIBRID LOG-PERIODICA DE BANDA LARGA PENTRU MASURATORI EMC 26 MHZ..6 GHZ ETS-LINDGREN 3142D

• Frequency Range 26 MHz - 60 MHz, 60 MHz - 600 MHz, 600 MHz - 1 GHz, 1 GHz - 6 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 500 W, 1 kW, 500 W, 200 W
• VSWR 2.0:1

 

CONDENSATOARE RFI/ EMI DE ALIMENTARE CIRCUITE AC SI DC ETS-LINDGREN L265X

• All brass construction
• Excellent dv/dt characteristics
• These filters have NATO stock number codification
• High voltage proof withstand
• Design to meet Class Y specification

 

ANTENA HORN PENTRU MASURATORI EMC 18..40 GHZ ETS-LINDGREN 3116B

• Frequency Minimum 18 GHz
• Frequency Maximum 40 GHz
• VSWR Ratio (AVG) 2.5:1 max
• Maximum Continuous Power 20 W
• Peak Power 200 W
• Impedance (Nominal) 50 ?

 

MATERIALE ABSORBTIE RADIATII EMC SI MICROUNDE ETS-LINDGREN

• EMC Anechoic Absorber
• Ferrite Tile Absorber
• FerroSorb FS EMC Absorber
• FerroSorb PS EMC Absorber
• Ultra Broadband Microwave Absorber

 

ANTENA BUCLA PASIVA TESTARE ECRANARE SI IMUNITATE RADIATII 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

INTERFATA WIRELESS TESTARE TELEFOANE MOBILE IN COMUNICATII CELULARE ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz