Filtru putere aplicatii Tempest/ EMP de mare performanta curenti 16..200A ETS-Lindgren N600X

Cod: ETS-Lindgren N600X


 

Brosura produs PDF, 0.64 Mb

Descriere

  • Suitable for 400Hz supplies
  • Compact Rugged Construction
  • Maximum Protection for EMP and Tempest applications
  • Current Range 16 to 200 Amperes
  • 100 dB Insertion Loss from 14 kHz to 40 GHz
  • Low power dissipation

 

APPLICATIONS

  • In high performance screened rooms and anechoic chambers the N600X series provides protection of both incoming and outgoing supplies in line with the shield performance.
  • In TEMPEST applications, the N600X filters provide an extremely high degree of protection required to obtain maximum security.
  • N600X filters are ideal for EMP applications needing to meet the most stringent NATO requirements.
  • N600X filters can be used for filtering of mains incomers entering screened room facilities.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Frequency (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz System Per Line (Max)

Full Load Dissipation (W)

6000

16

250

DC/50/60/400

2

1.2

35

6001

16

440/250

DC/50/60/400

4

1

45

6002

32

250

DC/50/60/400

2

1.1

70

6003

32

440/250

DC/50/60/400

4

0.75

50

6004

63

250

DC/50/60/400

2

1.3

68

6005

63

440/250

DC/50/60/400

4

0.75

155

6006

100

250

DC/50/60/400

2

0.7

135

6007

100

440/250

DC/50/60/400

4

0.5

135

6009

200

440/250

DC/50/60/400

4

1

400

 

Alte produse ETS-LINDGREN

ANTENA HORN DESCHISA CUADRI-CREASTA 2..18 GHZ ETS-LINDGREN 3164-05

• Frequency Minimum 2 GHz
• Frequency Maximum 18 GHz
• Connectors SMA Female
• Cross Polarization Isolation >24 dB
• Impedance (Nominal) 50 ?
• Maximum Power 25 W
• Pattern Type directional
• Polarization dual linear

 

CAMERA ECRANATA TESTARE EMI/RFI ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

INTERFATA WIRELESS TESTARE TELEFOANE MOBILE IN COMUNICATII CELULARE ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz

 

ANTENA LOG-PERIODICA POLARITATE LINIARA DUBLA 100 MHZ..1.1 GHZ ETS-LINDGREN 3145BDP

• Frequency Range 100 MHz - 1.1 GHz
• Input Impedance 50 ?
• VSWR 1.5:1 average, 3.5:1 maximum
• Maximum RF input power 800 W
• Stainless Steel Construction
• Dual Linearly Polarized

 

ANTENA HORN CONICA LINIAR POLARIZATA SI CASTIG RIDICAT 4..26.5 GHZ ETS-LINDGREN 3163

• Conical Shape
• Series Frequency Range: 4 GHz to 26.5 GHz
• High Gain
• Low VSWR

 

ANTENA HORN GHID DE UNDE PENTRU MASURATORI EMC 400 MHZ..6 GHZ ETS-LINDGREN 3119

• Frequency Minimum 400 MHz
• Frequency Maximum 6 GHz
• VSWR Ratio (AVG) 3.5:1 max
• <2:1 above 500 MHz
• Maximum Continuous Power 1500 W @ 400 MHz, 800 W @ 6 GHz
• Peak Power 2500 W

 

SONDE MASURA CURENTI 10 KHZ..1000 MHZ ETS-LINDGREN

• 10 kHz..1000 MHz Frequency ranges
• For Standards Testing and Pre-compliance Applications
• Measures RF Current Without Direct Connection

 

ANTENA BUCLA PASIVA TESTARE ECRANARE SI IMUNITATE RADIATII 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

GENERATOR DE CAMP ELECTRIC LINIAR POLARIZAT 10 KHZ..30 MHZ ETS-LINDGREN 3107B

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1000 W
• Peak Power 1500 W
• Polarization linear
• Linear Polarization

 

FILTRE EMI DE PUTERE RETELE MONOFAZATE APLICATII TEMPEST/ EMC 32..120A ETS-LINDGREN N192X

• Current Range 32 to 250 Amperes
• Very High RF Attenuation
• Fully Tested for Attenuation Performance
• Durable Construction
• CE Marked