Impulse Noise Simulator EMC Testing NoiseKen INS-4020/ 4040

Code: NoiseKen INS-4020/ 4040


 

Datasheet PDF, 1.52 Mb

Description

The NoiseKen's Impulse Noise Simulator INS-4020/4040 is a further development from our versatile INS series simulators for greater ease of use, durability and reliability with new technologies specifically applied to this new product. The most significant addition is automatic ramp operation in output voltage, pulse repetition period and phase angle placement.

 

  • INS-4020 (2kV) : 0.01 ~ 2.00KV ±10% with 50 ohm load, 10V step
  • INS-4040(4kV) : 0.01 ~ 4.00KV ±10% with 50 ohm load, 10V step
  • Automatic ramp operation for output voltage, phase angle and repetition period
  • Floating output
  • Coupling mode selection by plugging the supplied coaxial connector to the selected port
  • Easily changeable mercury relay unit
  • Built-in 50 ohm terminator
  • Up to 5 test settings stored in the internal momory
  • Easily changeable outlet panels
  • CE marked

 

SPECIFICATIONS

 

Item

Model

INS-4020 (2kV)

INS-4040(4kV)

Output voltage

0.01 ~ 2.00KV ±10% with 50 ohm load, 10V step

0.01 ~ 4.00KV ±10% with 50 ohm load, 10V step

Polarity

Positive or negative

Square wave

Pulse width

50ns, 100 ns, 200ns, 250ns, 400ns, and any combination thereof, maximum width, 1µs or 10ns±3ns (the shortest connection)

Pulse rise time

< 1ns

Output impedance

50 ohm system (53.5 ohm)

Pulse repetition mode

VARIABLE

10ms ~ 999ms±10%, 1ms step

16ms ~ 999ms±10%, 1ms step

PHASE

50 or 60Hz, Injection phase angle 0~359°, 1° step, synchronized with L1 - L2 power line frequency for EUT

EXT

<EXT mode>
>10ms, Pulse width>1ms
TTL/Open collector negative logic

<EXT mode>
>16ms, Pulse width>1ms
TTL/Open collector negative logic

Also functions for timing reference signals input from an external injection unit

1 SHOT

Single pulse injection to the angle selected by PHASE setting, or irrelevant with the EUT line frequency

Memory

Up to 5 test settings

Power capacity of equipment under test

AC 240V, DC60V, Single phase, DC60V 16A

Power supply

AC100 ~ 240V 50/60H

Power consumption

140VA

Operating temperature and humidity

15~35°C / 25~75% (No dewing shall occur.)

Dimensions

(W) 430 X (H) 249 X (D) 420 mm(Projections excluded)

Weight

Approx. 19kgs

 

Standard accessories

 

 
 

More products NOISEKEN

PULSE 3A, 3B GENERATOR AUTOMOTIVE TRANSIENT SURGE SIMULATOR NOISEKEN ISS-7630

• Pulse 3a and Pulse 3b generating unit
• A built-in 60V/30A Coupling Network allows independent operation.
• <3.5ns rise time pulse available
• Runs in pulse repetition frequencies sweep mode from 1 kHz to 100 kHz (ISS-7601 software required)


FAST TRANSIENT BURST SIMULATOR NOISEKEN FNS-AX3

• 4.8kV maximum peak voltage
• 2MHz pulse repetition rate
• Conforming to IEC/EN 61000-4-4 (Second Edition-2004)
• Reverse polarity per burst
• Automatic ramp operation
• Manual, IEC level and sequence modes

 

ESD ELECTROSTATIC DISCHARGE SIMULATOR FOR SEMICONDUCTOR CIRCUITS NOISEKEN ESS-6002/ 6008

• ESS-6002 Output voltage: 10V ~2.0kV ±10% (1V step)
• ESS-6008 Output voltage: 100V ~ 8.0 kV±10% (10V step)
• A simple probe stand and test fixture plus a pair of miniature test leads
• Narrow pitch DUT can be tested in semi-automatic manner
• Each probe has a coaxial interface with an external measuring instrument.

 

RF EMISSION RADIATION PRECISION SCANNER NOISEKEN EPS-3007

• Provides an amplitude versus frequency plot for each antenna probe position and field intensity distribution map by a single scan
• Electric and magnetic fields are separately detected
• 3D graphical representation and zoom capability for a given area
• Comparison before and after a modification or improvement
• Scanning by a single antenna probe to minimize error between each measurement point
• 3GHz maximum frequency response (option)
• Standard included three kinds of antenna probes (Probe A, Probe B and Probe C)

 

PULSE 5A, 5B GENERATOR AUTOMOTIVE TRANSIENT SURGE SIMULATOR NOISEKEN ISS-7650

• Pulse 5a and Pulse 5b generating unit
• A built-in 60V/30A Coupling Network allows independent operation.
• Capacitive - resistive (inductive) discharge circuitry in strict conformity with the standard and with the actual car environment.
• Equipped with a programmable clip circuit that can produce Pulse 5b clipped waveform in steps of 0.1V without externally attaching a zener diode.
• Pulse 5b clipped waveform is pre-eminent in smoothness.


PULSE 1, 2A GENERATOR AUTOMOTIVE TRANSIENT SURGE SIMULATOR NOISEKEN ISS-7610

• Pulse 1 and Pulse 2a generating unit
• A built-in 60V/30A Coupling Network allows independent operation.
• Wide variety of selections of the output resistances Ri and Pulse Widths td and their combinations


LIGHTING SURGE SIMULATOR NOISEKEN LSS-6230

• Lightning Surge Simulator conforming to IEC61000-4-5 ed2 Standard
• Ring wave conforming to ANSI/IEEE C62.45 available
• Max. voltage 6.6kV output focusing on the practical use
• Monitor terminal standard equipped so as for easy waveform pre-checking
• Interlock built-in as the emergency stop function for safety

 

SOURCE-VOLTAGE DIP AND SWELL SIMULATOR NOISEKEN VDS-1007/ 2007

• VDS-1007 : 1kVA Power
• VDS-2007 : 2kVA Power
• Enable to enrich EMC preliminary tests with the remote control as an AC stabilizing power source
• Enable IEC61000-4-11/13/14/28 precompliant tests
• Usable to be power source for IEC61000-3-2-2 precompliant measurement

 

HIGH VOLTAGE LIGHTING SURGE SIMULATOR NOISEKEN LSS-F02

• "Output voltage 15kV, current 7500A" which can conduct breakdown resistibility test
• "50% reduction of the output interval" which can drastically reduce the test time
• "Touch-panel" adopted for the easy test setting
• "Multi-languages" for the easy operation processing available
• "Indicator" which is linked with the test setting equipped
• PC control available with the optional software
• "Emergency stop" & "Interlock terminal" which secure the test operator equipped

 

ESD ELECTROSTATIC DISCHARGE SIMULATOR NOISEKEN ESS-S3011

• 0.2 to 30.0kV +/-5% (30.5kV Maximum)
• 0.2 to 10kV: 0.05V step, 10.0 to 30.0kV: 0.1kV step
• EN/IEC 61000-4-2 Ed2 Compliant
• ISO 10605 Ed2 Compliant
• Pre-test
• Ten-key & Rotary knob to ease the setting
• Infra-red Remote Controller to allow remote Generator setting