Impulse Noise Simulator EMC Testing NoiseKen INS-4020/ 4040

Code: NoiseKen INS-4020/ 4040


 

Datasheet PDF, 1.52 Mb

Description

The NoiseKen's Impulse Noise Simulator INS-4020/4040 is a further development from our versatile INS series simulators for greater ease of use, durability and reliability with new technologies specifically applied to this new product. The most significant addition is automatic ramp operation in output voltage, pulse repetition period and phase angle placement.

 

  • INS-4020 (2kV) : 0.01 ~ 2.00KV ±10% with 50 ohm load, 10V step
  • INS-4040(4kV) : 0.01 ~ 4.00KV ±10% with 50 ohm load, 10V step
  • Automatic ramp operation for output voltage, phase angle and repetition period
  • Floating output
  • Coupling mode selection by plugging the supplied coaxial connector to the selected port
  • Easily changeable mercury relay unit
  • Built-in 50 ohm terminator
  • Up to 5 test settings stored in the internal momory
  • Easily changeable outlet panels
  • CE marked

 

SPECIFICATIONS

 

Item

Model

INS-4020 (2kV)

INS-4040(4kV)

Output voltage

0.01 ~ 2.00KV ±10% with 50 ohm load, 10V step

0.01 ~ 4.00KV ±10% with 50 ohm load, 10V step

Polarity

Positive or negative

Square wave

Pulse width

50ns, 100 ns, 200ns, 250ns, 400ns, and any combination thereof, maximum width, 1µs or 10ns±3ns (the shortest connection)

Pulse rise time

< 1ns

Output impedance

50 ohm system (53.5 ohm)

Pulse repetition mode

VARIABLE

10ms ~ 999ms±10%, 1ms step

16ms ~ 999ms±10%, 1ms step

PHASE

50 or 60Hz, Injection phase angle 0~359°, 1° step, synchronized with L1 - L2 power line frequency for EUT

EXT

<EXT mode>
>10ms, Pulse width>1ms
TTL/Open collector negative logic

<EXT mode>
>16ms, Pulse width>1ms
TTL/Open collector negative logic

Also functions for timing reference signals input from an external injection unit

1 SHOT

Single pulse injection to the angle selected by PHASE setting, or irrelevant with the EUT line frequency

Memory

Up to 5 test settings

Power capacity of equipment under test

AC 240V, DC60V, Single phase, DC60V 16A

Power supply

AC100 ~ 240V 50/60H

Power consumption

140VA

Operating temperature and humidity

15~35°C / 25~75% (No dewing shall occur.)

Dimensions

(W) 430 X (H) 249 X (D) 420 mm(Projections excluded)

Weight

Approx. 19kgs

 

Standard accessories

 

 
 

More products NOISEKEN

PULSE 2B, 4 GENERATOR AUTOMOTIVE TRANSIENT SURGE SIMULATOR NOISEKEN BP4610

• Pulse 2b and Pulse 4 generating unit
• +-60V 10A DC - 150kHz built-In bipolar amplifier
• Functions as the DUT power supply for testing with the other pulses
• Upgradeable to 15A or 30A by use of an optional external power supply


RF EMISSION RADIATION PRECISION SCANNER NOISEKEN EPS-3007

• Provides an amplitude versus frequency plot for each antenna probe position and field intensity distribution map by a single scan
• Electric and magnetic fields are separately detected
• 3D graphical representation and zoom capability for a given area
• Comparison before and after a modification or improvement
• Scanning by a single antenna probe to minimize error between each measurement point
• 3GHz maximum frequency response (option)
• Standard included three kinds of antenna probes (Probe A, Probe B and Probe C)

 

VOLTAGE DIP AND SWELL WAVEFORMS SIMULATOR NOISEKEN VDS-2002

• Conforming to IEC 61000-4-11
• Fully compliant with all the test generator requirements of IEC standard.
• One unit solution for dip, swell, interruption and variation tests up to 16A 290V single phase AC
• Interruption test up to 16A 125V DC (*)
• Two motor-driven transformers approach enables switching between any voltages (*)
• Preset IEC test levels 0%/40%/70%/80% plus additional 120%

 

ESD ELECTROSTATIC DISCHARGE SIMULATOR NOISEKEN ESS-B3011/ESS-L1611

• ESS-B3011 : 0.2 to 30.0kV
• ESS-L1611 : 0.2 to 16.0kV
• EN/IEC 61000-4-2 Ed2 Compliant (B3011/L1611)
• ISO 10605 Ed2 Compliant (B3011/L1611)
• 3 pre-checking function taking the confirmable test into the account (B3011/L1611)
• Discharge detecting function to realize the air-discharge confirmation (B3011/L1611)
• Lightest Discharge Gun in the market to lighten the continuous operation (GT-30R)

 

ESD ELECTROSTATIC DISCHARGE SIMULATOR NOISEKEN ESS-2000AX

• 0.20kV~30.0kV Output voltage range
• Fully programmable menu-driven simulator providing three operation modes: IEC standard, Manual and Sequence
• 5.7-inch color LCD for easy setting and good visibility
• Unique shape for the operator's easy access to the controls and displays even when the unit is put on the floor level (ground plane)
• Communications with PC through the optic serial interface
• wide variety of the dedicated options

 

PULSE 5A, 5B GENERATOR AUTOMOTIVE TRANSIENT SURGE SIMULATOR NOISEKEN ISS-7650

• Pulse 5a and Pulse 5b generating unit
• A built-in 60V/30A Coupling Network allows independent operation.
• Capacitive - resistive (inductive) discharge circuitry in strict conformity with the standard and with the actual car environment.
• Equipped with a programmable clip circuit that can produce Pulse 5b clipped waveform in steps of 0.1V without externally attaching a zener diode.
• Pulse 5b clipped waveform is pre-eminent in smoothness.


IMPULSE NOISE SIMULATOR EMC TESTING NOISEKEN INS-4020/ 4040

• INS-4020 (2kV) : 0.01 ~ 2.00KV ±10% with 50 ohm load, 10V step
• INS-4040(4kV) : 0.01 ~ 4.00KV ±10% with 50 ohm load, 10V step
• Automatic ramp operation for output voltage, phase angle and repetition period
• Floating output
• Coupling mode selection by plugging the supplied coaxial connector to the selected port
• Easily changeable mercury relay unit

 

PULSE 3A, 3B GENERATOR AUTOMOTIVE TRANSIENT SURGE SIMULATOR NOISEKEN ISS-7630

• Pulse 3a and Pulse 3b generating unit
• A built-in 60V/30A Coupling Network allows independent operation.
• <3.5ns rise time pulse available
• Runs in pulse repetition frequencies sweep mode from 1 kHz to 100 kHz (ISS-7601 software required)


PULSE 1, 2A GENERATOR AUTOMOTIVE TRANSIENT SURGE SIMULATOR NOISEKEN ISS-7610

• Pulse 1 and Pulse 2a generating unit
• A built-in 60V/30A Coupling Network allows independent operation.
• Wide variety of selections of the output resistances Ri and Pulse Widths td and their combinations


PCB BOARDS RADIATION EMISSIONS MEASUREMENT SYSTEM NOISEKEN EPS-6000

• Measurable up to 8GHz in the frequency range
• 4 axes (X, Y, Z, ?) measurements with minute step minimum 0.1m realized
• Equivalent distance measurement to parts on PCBs even the heights are different
• Composite figure of photo of the measured PCB and the measurement data realized
• Rich magnetic field probes in the figures, sizes and Vertical/Horizontal directions
• Versatile display for the measurement data as 2 dimensions, 3 dimension, and equiangular line realized