ESD Electrostatic Discharge Simulator NoiseKen ESS-S3011

Code: NoiseKen ESS-S3011


 

Datasheet PDF, 0.37 Mb
                           

Description

  • 0.2 to 30.0kV +/-5% (30.5kV Maximum)
  • 0.2 to 10kV: 0.05V step,  10.0 to 30.0kV: 0.1kV step
  • EN/IEC 61000-4-2 Ed2 Compliant
  • ISO 10605 Ed2 Compliant
  • Pre-test
  • 3 pre-checking functions taking the confirmable test into the account
  • CR constant indicator to ensure correct attachment is in place
  • During test
  • Ten-key & Rotary knob to ease the setting
  • Infra-red Remote Controller to allow remote Generator setting
  • Discharge Detecting Function to realize the air-discharge confirmation
  • Lightest Discharge Gun in the market" for better continuous operation
  • White LED light" to show Discharging points 
  • After test
  • Control Software" for Test Result Reporting and PC Control
  • (Scheduled to be downloaded from NoiseKen web-site)

 

 

ESD Simulator Main Unit Model : ESS-S3011

 

Items

ESS-S3011 specifications

Polarity

Positive or negative

Output voltage

0.2 to 30.0kV +/-5% (30.5kV Maximum)

0.2 to 10kV: 0.05V step,  10.0 to 30.0kV: 0.1kV step

Repetition cycle

0.05s to 99.9s +/-10% / Manual

0.05s to 10.0s: 0.05s step,  10.0 to 99.9s: 0.10s step

No. of time of discharge

1 to 60,000 times /continuous

 Discharge mode

Contac discharge / Air discharge

Radiation level mode

Normal mode / Extra mode

Trigger mode

Gun trigger / Main unit trigger / External trigger

Operation panel

Color LCD / Push-buttons (Partially lighting)

Gun holder

Standard attached (to hold the discharge gun Model GT-30R)

Radiation mode select switch

Extra / Normal switching function built-in

Discharge detection

Discharge detection function in air-discharge mode equipped

Pre-checking function

Following 3 steps function equipped (by under operation. Not the calibration but just checking)
SETP1: High voltage output checking
STEP2: Withstanding voltage checking
STEP3: Discharge relay operation checking

CR & Gun head checking

 CR constant and gun head recognizable (with an indicator to prevent the wrong combination)

Power supply

100V to 240V AC   50/60 Hz  +/-10%

IEC standard test mode

Contact discharge mode: 2.0, 4.0, 6.0, 8.0 kV step

Air discharge mode: 2.0, 4.0, 8.0, 15.0 kV step

Manual test mode

Contact/Air discharge mode: 0.20kV to 30.0kV

Sweep function available

Up to 50 units (test settings) storable

Sequence test mode

Seamless run of the selected test sequence

No. of steps per one sequence: up to 22 steps

No. of test sequences: up to 20

Warning lamp

Lights up while the HV circuitry is on.

Blinks while discharges are in progress.

Charging capacitor and resistance

150pF +/-10%, 330 ohm+/-10%  (built into Discharge Gun GT-30R)

Main unit charging resistance

10M ohm (53M ohm for combination with Discharge Gun GT-30R)

AUX connector

D-SUB 15 pin, female connector

Connection of Warning Lamp (optional)

Connection of Automatic ESD Eliminator (optional)

External interlock input

External trigger input

Optical communication connector

Optic connector for PC communication (serial interface)

Power supply/ Power consumption

100V to 240V AC, 50Hz/60Hz +/-10%  75VA

Display characters

English, Chinese, Korean,  Japanese

Included accessories

Remote controller 13-00004A, Gun holder, Instruction manual

Dimensions and weight

 (W) 270 X  (H)312 X  (D)295 mm (projection and the gun holder excluded)
Approx. 7.0kg (gun holder excluded)  , Approx. 7.5kg (gun holder included)  

 

 

Discharge Gun Model :  GT-30R 

 

Items

GT-30R specifications

Output voltage

30.5kV Max

Polarity

Positive or Negative

Repetition cycle

0.05s and over   Note) Guaranteed value is 0.1s and over  (330pF and under)

Discharge mode

Contact or Air

Charging resistor

Built-in CR unit

Charge/Discharge capacitor & Discharge resistor

Built-in CR unit

High voltage connector

Composite connector of high voltage and signal line (male)  (NoiseKen custom)

Operation switch

Discharge trigger

LED irradiator

White LED light built-in for irradiating EUT (Focusing point is the tip)

Included accessories

CR unit (150pf-330 ohm) 06-00073A

Conical discharge tip 12-00007A

Round discharge tip 12-00008A

Instruction manual  

Dimensions and weight

  (W) 83X  (H) 217 X  (D) 229 mm  (projection excluded)
Approx. 0.8kg (Cable and connector excluded)

Approx. 10.8kg (Cable included, connecter excluded)

 
 

More products NOISEKEN

ESD ELECTROSTATIC DISCHARGE SIMULATOR NOISEKEN ESS-2000AX

• 0.20kV~30.0kV Output voltage range
• Fully programmable menu-driven simulator providing three operation modes: IEC standard, Manual and Sequence
• 5.7-inch color LCD for easy setting and good visibility
• Unique shape for the operator's easy access to the controls and displays even when the unit is put on the floor level (ground plane)
• Communications with PC through the optic serial interface
• wide variety of the dedicated options

 

ESD ELECTROSTATIC DISCHARGE SIMULATOR NOISEKEN ESS-B3011/ESS-L1611

• ESS-B3011 : 0.2 to 30.0kV
• ESS-L1611 : 0.2 to 16.0kV
• EN/IEC 61000-4-2 Ed2 Compliant (B3011/L1611)
• ISO 10605 Ed2 Compliant (B3011/L1611)
• 3 pre-checking function taking the confirmable test into the account (B3011/L1611)
• Discharge detecting function to realize the air-discharge confirmation (B3011/L1611)
• Lightest Discharge Gun in the market to lighten the continuous operation (GT-30R)

 

ESD ELECTROSTATIC DISCHARGE SIMULATOR NOISEKEN ESS-S3011

• 0.2 to 30.0kV +/-5% (30.5kV Maximum)
• 0.2 to 10kV: 0.05V step, 10.0 to 30.0kV: 0.1kV step
• EN/IEC 61000-4-2 Ed2 Compliant
• ISO 10605 Ed2 Compliant
• Pre-test
• Ten-key & Rotary knob to ease the setting
• Infra-red Remote Controller to allow remote Generator setting

 

PULSE 1, 2A GENERATOR AUTOMOTIVE TRANSIENT SURGE SIMULATOR NOISEKEN ISS-7610

• Pulse 1 and Pulse 2a generating unit
• A built-in 60V/30A Coupling Network allows independent operation.
• Wide variety of selections of the output resistances Ri and Pulse Widths td and their combinations


SOURCE-VOLTAGE DIP AND SWELL SIMULATOR NOISEKEN VDS-1007/ 2007

• VDS-1007 : 1kVA Power
• VDS-2007 : 2kVA Power
• Enable to enrich EMC preliminary tests with the remote control as an AC stabilizing power source
• Enable IEC61000-4-11/13/14/28 precompliant tests
• Usable to be power source for IEC61000-3-2-2 precompliant measurement

 

PULSE 5A, 5B GENERATOR AUTOMOTIVE TRANSIENT SURGE SIMULATOR NOISEKEN ISS-7650

• Pulse 5a and Pulse 5b generating unit
• A built-in 60V/30A Coupling Network allows independent operation.
• Capacitive - resistive (inductive) discharge circuitry in strict conformity with the standard and with the actual car environment.
• Equipped with a programmable clip circuit that can produce Pulse 5b clipped waveform in steps of 0.1V without externally attaching a zener diode.
• Pulse 5b clipped waveform is pre-eminent in smoothness.


IMPULSE NOISE SIMULATOR EMC TESTING NOISEKEN INS-4020/ 4040

• INS-4020 (2kV) : 0.01 ~ 2.00KV ±10% with 50 ohm load, 10V step
• INS-4040(4kV) : 0.01 ~ 4.00KV ±10% with 50 ohm load, 10V step
• Automatic ramp operation for output voltage, phase angle and repetition period
• Floating output
• Coupling mode selection by plugging the supplied coaxial connector to the selected port
• Easily changeable mercury relay unit

 

VOLTAGE DIP AND SWELL WAVEFORMS SIMULATOR NOISEKEN VDS-2002

• Conforming to IEC 61000-4-11
• Fully compliant with all the test generator requirements of IEC standard.
• One unit solution for dip, swell, interruption and variation tests up to 16A 290V single phase AC
• Interruption test up to 16A 125V DC (*)
• Two motor-driven transformers approach enables switching between any voltages (*)
• Preset IEC test levels 0%/40%/70%/80% plus additional 120%

 

FAST TRANSIENT BURST SIMULATOR NOISEKEN FNS-AX3

• 4.8kV maximum peak voltage
• 2MHz pulse repetition rate
• Conforming to IEC/EN 61000-4-4 (Second Edition-2004)
• Reverse polarity per burst
• Automatic ramp operation
• Manual, IEC level and sequence modes

 

HIGH VOLTAGE LIGHTING SURGE SIMULATOR NOISEKEN LSS-F02

• "Output voltage 15kV, current 7500A" which can conduct breakdown resistibility test
• "50% reduction of the output interval" which can drastically reduce the test time
• "Touch-panel" adopted for the easy test setting
• "Multi-languages" for the easy operation processing available
• "Indicator" which is linked with the test setting equipped
• PC control available with the optional software
• "Emergency stop" & "Interlock terminal" which secure the test operator equipped