Multifunction Instrument for Testing & Veryfying Single Phase Photovoltaic Installations HT Italia Solar I-V
OBSOLET PRODUCT ( * OUT OF USE )

Code: HT Italia Solar I-V


 

Datasheet PDF, 1.07 Mb

Description

  • Testing on PV installation
  • DC/AC TRMS Voltage
  • DC/AC TRMS Current
  • DC power
  • AC active power on single-phase systems
  • Solar irradiation [W/m2] with reference cell
  • Temperature environmental and module by means of probe PT1000
  • Synchronization with remote unit SOLAR-02
  • Display of real-time irradiation and temperature
  • Use of PDC compensation ratios according to environmental and module temperature
  • Recording of parameters with programmable IP (5s - 60min)
  • Internal memory for data saving
  • Recalling results on the display
  • Optical/USB port for PC connection
  • Help on line on the display

 

  • I-V curve measurement
  • Measurement of output voltage from module/string up to 1000V DC
  • Measurement of output current from module/string up to 10A DC
  • Measurement of solar irradiation [W/m2] with reference cell
  • Measurement of environmental and module temperature, automatic or by means PT1000
  • Measurement of output DC and nominal power from module/string
  • Numerical and graphical display of I-V characteristic
  • Measurement of the resistance of photovoltaic module series
  • Mechanical inclinometer for the detection of the incidence angle of solar irradiation
  • 4-terminal measuring method
  • Comparison with standard conditions (STC 1000 W/m2, 25°C)
  • Evaluation of testing result: OK / NO
  • Management of up to 30 types of photovoltaic modules in the internal database
  • Internal memory for data saving
  • Recalling results on the display
  • Optical/USB port for PC connection
  • Help on line on the display
 

Standard accessories

  • SOLAR-02: RF remote unit to record irradiation and temperature
  • KITGSC4: Kit including 4 banana cables + 4 alligator clips
  • KITPVMC3: Kit including 2 Multi-Contact 3 adapters for MC3 connectors
  • KITPVMC4: Kit including 2 Multi-Contact 3 adapters for MC4 connectors
  • HT4005K: Transducer for AC currents 200A/1V AC
  • HT4004N: Transducer for DC currents 10-100A/1V DC
  • HT304: reference cell for irradiation measurement
  • PT300N: Double temperature probe (PT1000 + environmental)
  • M304: Mechanical inclinometer
  • TOPVIEW2006: Software on CD-ROM + optical/USB connection cable C2006
  • BORSA2051: Carrying case
  • User manual on CD-ROM
  • Quick reference guide
  • Calibration certificate ISO9000
 

Recommended options

  • MPP300: Multi-string three phase adaptor
  • HT4004P: Unbatteried transducer for DC current 0-10, 0-100A, diameter 30mm (*)
  • HT96U: Transducer for AC currents 1-100-1000A/1VAC
  • HT97U: Transducer for AC currents 10-100-1000A/1VAC
  • HT98U: Transducer for AC/DC currents 1000 A AC/DC
  • HTFLEX33D: Flexible clamp AC 3000A, diameter 174mm (*)
  • HTFLEX35: Flexible clamp AC 3000A, diameter 274mm (*)
  • KITPVEXT25M: set of 2 banana cable 4mm, Green/Black, 25m lenght
  • SP-0400: Free hands kit
  • 606-IECN: Connector with magnetic clip
  • (*) to be used with MPP300 only
 

More products HT ITALIA

DIGITAL PORTABLE MULTIMETERS HT ITALIA

• DC Voltage
• AC TRMS Voltage
• DC Current
• AC TRMS Current

 

STEP AND CONTACT VOLTAGE METER WITH TEST CURRENT UP TO 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

THT600 INFRARED CAMERA 384X288PXL

• IR Resolution 384x288 pxl
• Temperature range -20° ÷ 650°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 17° x 12.7°

 

HT GSC60 MULTIFUNCTION ELECTRICAL INSTALLATION TESTER WITH POWER QUALITY ANALYSIS

• Insulation with voltage 50, 100, 250, 500, 1000VDC
• Three-phase Power quality and Energy consumption analysis
• 632 parameters can be recorded for over two months
• Voltage/current vector diagram
• Voltage/current waveforms
• Tables or histograms of Harmonics and THD%
• Integrated WiFi connection and compatibility with HTANALYSIS App

 

DIGITAL PROCESS CALIBRATOR PORTABLE MULTIMETER HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

SAFETY TESTER FOR PHOTOVOLTAIC SYSTEMS HT PVCHECK

• Safety test of PV installation
• Continuity test on protective conductors with 200mA
• Insulation test with test voltage of 250, 500, 1000VDC
• DC voltage
• DC current
• DC Power
• Solar irradiation [W/m2] with reference cell

 

HT PQA924 CLASS S POWER QUALITY AND ENERGY ANALYZER

• AC voltage in single-phase and three-phase systems
• AC current in single-phase and three-phase systems
• Cosphi, Power Factor, K-Factor
• Voltage unbalance
• Flicker
• Active, Reactive, and Apparent power/energy
• Voltage and current harmonic amplitude and phase up to the 63rd order with THD% calculation

 

DIGITAL PROGRAMMABLE PROFESSIONAL MEGOHMMETER 10TOHM 5KV HT ITALIA HT7051

• Insulation resistance measurement with test voltage up to 5kVDC
• Measurement range up to 10Tohm
• Polarization Index (P.I.) measurement
• Dielectric Absorption Ratio (D.A.R) measurement
• RS-232 interface for PC connection
• Rechargeable internal battery

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage