HT GSC60 Multifunction Electrical Installation Tester with Power Quality Analysis

Code: GSC60 HV000060


 

Datasheet PDF, 0.4 Mb
Datasheet PDF, 0.5 Mb

Description

One instrument for all electrical safety tests and Power Quality analysis
GSC60 was designed with the aim of making safety of electrical installations visible and valuable, easily and quickly.
Thanks to the new HTOS™ system the unit displays a message OK - NOT OK after completing the test.
The user interface, totally updated under HTOS™, permits to set and carry out measurements in few steps.
You can store all recorded data and create folders and subfolders for each kind of test adding comments and notes by means of virtual keyboard.
GSC60 is also a three-phase power and energy consumption analyzer boasting, as unique feature, its FREE APP HTAnalysis compatible with iOS and Android.
Test results can be transferred through Wi-Fi onto smartphone or tablet enclosing a picture, a video or a voice note to each measurement. You can transfer everything onto HT Cloud and make data available in real time for your colleagues all over the world.
GSC60 makes the job of installer, electrician or consultant easy, rapid and cost-effective.

HTOS™Control the Power.

Get access through touchscreen to your measurement. Quickly set measurement parameters and press GO. Here it is, HTOS™, designed to make your work easier. Its’ result options OK and NOT OK as well as its Help OnLine will make it your best partner and save you time.

 

Evolution of saving.

Virtual keyboard to enter comments
Saving on file structure
New detailed reports with TopView software

Electrical safety measurements

AUTO Function to work easier.
Rapid setting of limit values and test voltages
through virtual keyboard
Setting of Timer for the test where is available.

Earth Resistance

Earth resistance with 2- or 3-pole volt-ampere method in TT, TN and IT systems.
Soil resistivity with 4-pole Wenner method.
Stackless earth ground resistance measurement with T2100
Non-trip earth loop impedance measurement

Power Quality and energy analysis

9 types of electrical systems available.
632 parameters can be recorded for over two months.
Real-time display of all waveforms, harmonics, vector diagrams as well as summary function on phases for a quick reading of the most important parameters.
Detection of voltage anomalies with a resolution of 20ms.
Measures and record the electrical absorption of all the equipment connected to the main power supply.

Full Batteries at All Times.

GSC60 is so compact that a new power technology had to be designed to charge batteries.
You just need to power the unit and it will charge the batteries.
Or you can always start working by simply replacing them with standard AA batteries.

All in real time!

Wi-Fi connection allows you to display on your tablet/smartphone/PC in real time:

Waveforms
Vector Diagrams
Harmonics
All parameters of each phase

Zoom, Zoom, Zoom! Enlarge, Jump, Analyze. Two finger needed.

With HTAnalysis™ you can:

Analyze the full recording on your device
Compare up to 16 quantities at the same time Immediately analyze
events like voltage dips and peaks
Use the JUMP function to know the energy consumption anytime
Use again the JUMP function to display to display the harmonicsin
any point of the recording

HTAnalysis™ and the electrical safety

During the measures campaigns you can:

Add text and vocal comments
Add to each measure photos and videos
Customize your measurements

HT Cloud™ Share.
Whenever, whatever and wherever.

Install App HTanalysis to avail yourself of HTCloud™ database and share measurement results and recordings with your colleagues anytime and from any place on the planet.

Functions
Touchscreen colour display 
Integrated WiFi connection and compatibility with HTANALYSIS App 
Continuity of protective circuit with 200mA 
Continuity of protective conductors with 10AWith optional accessory EQUITEST
Insulation with voltage 50, 100, 250, 500, 1000VDC 
Time/Current tripping of A, AC General, Selective and Delayed RCDs up to 1000mA 
Time/Current tripping of type B RCDs up to 300mA 
Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A 
Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current 
Line/Loop impedance with high resolution (with optional accessory IMP57) 
Percentage voltage drop on the line 
Measurement and recording of leakage currents and environment parameters 
Three-phase Power quality and Energy consumption analysis: 
9 types of electrical systems1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.
632 parameters can be recorded for over two months 
Voltage Anomalies (dips and peaks) with a resolution of 20ms@50Hz
Measurement/recording of Active, Reactive, Apparent Power 
Measurement/recording of Active, Reactive, Apparent Energy 
Measurement/recording of Cosphi, Power Factor 
Measurement/Recording of Voltage and Current Harmonics up to 49th with THD% 
Voltage/current vector diagram 
Voltage/current waveforms 
Tables or histograms of Harmonics and THD% 
Summary table of main electric parameters 
Help on line on the display 
Protection categoryCAT IV


Guidelines
 EMC: IEC/EN61326
 EN50160
 EN50522
 EN60909-0
 EN61936-1
 IEC/EN61010-031
 IEC/EN61010-1
 IEC/EN61010-2-032
 IEC/EN61187
 IEC/EN61557-1
 IEC/EN61557-10
 IEC/EN61557-2
 IEC/EN61557-3
 IEC/EN61557-4
 IEC/EN61557-5
 IEC/EN61557-6
 IEC/EN61557-7
 UNE20460

Video Presentation on Youtube HT GSC60





 

Standard accessories

STANDARD ACCESSORIES
Quick Guide and Downloadable Manual
Quick Guide and Downloadable Manual
Calibration report
Calibration report
HTFLEX33E x4
HTFLEX33E x4

VA500
VA500

PR400
PR400

5001-V
5001-V

C2033X
C2033X

5004-IECN
5004-IECN

UNIVERSALKITG3
UNIVERSALKITG3

YABAT0003000
YABAT0003000

KITTERRNE
KITTERRNE

C2006 + Downloadable Software
C2006 + Downloadable Software

RCDX10
RCDX10
PT400
PT400
SP-5100
SP-5100

A0061
A0061
 

Recommended options

OPTIONAL ACCESSORIES
HT96U
HT96U

HT97U
HT97U

HP30C2
HP30C2

HP30C3
HP30C3

HT4005K
HT4005K

HT4005N
HT4005N

HTFLEX35
HTFLEX35

HT98U
HT98U

HP30D1
HP30D1

HT4004
HT4004

HT52/05
HT52/05

HT53L/05
HT53L/05

BORSA2051
BORSA2051

404-IECN
404-IECN

607-IECN
607-IECN

1066-IECN
1066-IECN

5001-V
5001-V

5004-IECN
5004-IECN

T2100
T2100

404-IECB
404-IECB

1066-IECR
1066-IECR

5001-N
5001-N

5001-B
5001-B

5001-R
5001-R

404-IECV
404-IECV

5004-IECB
5004-IECB

5004-IECR
5004-IECR

5004-IECV
5004-IECV

HT4003
HT4003

IMP57
IMP57

RCDX10
RCDX10
404-IECR
404-IECR
EQUITEST
EQUITEST

 

More products HT ITALIA

HT GSC60 MULTIFUNCTION ELECTRICAL INSTALLATION TESTER WITH POWER QUALITY ANALYSIS

• Insulation with voltage 50, 100, 250, 500, 1000VDC
• Three-phase Power quality and Energy consumption analysis
• 632 parameters can be recorded for over two months
• Voltage/current vector diagram
• Voltage/current waveforms
• Tables or histograms of Harmonics and THD%
• Integrated WiFi connection and compatibility with HTANALYSIS App

 

PV-ISOTEST TESTER FOR CHECKING ELECTRIC SAFETY OF PHOTOVOLTAIC PANELS WITH GROUD FAULT LOCATION GFL FUNCTION

• Insulation measurement up to 1,500V DC even on live systems
• Localization of the faulty module through the new GFL function
• Continuity of the protective conductor with 200mA

 

HT8100 PROFESSIONAL PROCESS CALIBRATOR WITH MULTIMETER FUNCTIONS

• TRMS
• AC/DC voltage 1000V AC+DC
• AC/DC current 1A AC+DC
• DC 4-20mA current measurement
• DC 0-10V voltage measurement
• DC 4-20mA current generation

 

MULTIFUNCTION PORTABLE MULTIMETER FOR EARTH RESISTANCE MEASUREMENT HT ITALIA M73

• Trip out time measure on AC Standard RCD's
• Trip out current: 30, 30x5, 100, 300mA
• Global Earth Resistance with 0.1Ohm resolution
• Global Earth Resistance without RCD's tripping
• DC Voltage
• AC TRMS Voltage
• Automatic detection of AC/DC signals

 

HANDHELD DIGITAL MEGOHMMETER INSULATION & CONTINUITY 4 GOHM 1000V HT ITALIA M70

• Insulation with test voltage 250, 500, 1000VDC
• Up to 4Gohm measurement range
• Automatic discharge of device under test
• LOCK feature for continuous measurements
• Programmable timer up to 60s
• Continuity of earth conductors with test current of 200mA
• A/DC voltage up to 600V
• Resistance and continuity test with buzzer

 

ENVIRONEMENTAL MULTIFUNCTION TESTERS HT ITALIA

• Air temperature (°C/°F)
• Air relative humidity (%RH)
• Air speed (m/S)
• Air volume (m3/s)
• Capacity measurements (kW)
• Temperature dew point measurement

 

DIGITAL PROCESS CALIBRATOR PORTABLE MULTIMETER HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

HANDHELD DIGITAL SOUNDMETER WITH CALIBRATOR HT ITALIA HT154

• Measure of Sound Level Pressure (SPL)
• 0.1dB resolution
• Selection manual of range
• MAX/MIN display
• Frequency Weighting A and C
• Integration FAST/SLOW

 

INFRARED NON CONTACT THERMOMETER HT ITALIA

• Infrared temperature measurement from -50°C to 1000 °C
• Emissivity regulation
• Distance / Spot ratio of 50:1
• Laser pointer activation

 

I-V600 ADVANCED MULTIFUNCTION INSTRUMENT FOR I-V CURVE MEASUREMENTS UP TO 1500V AND 40A

• I-V curve tracing of mono-facial and bi-facial PV modules and strings up to 1500V/40A according to IEC/EN60891
• SOLAR03 remote unit with Bluetooth connection
• Up to 3 reference cells to measure front-side and rear-side radiation according to IEC TS 60904-1-2
• Database of over 30,000 photovoltaic modules manageable via connection with the new HT AGORÀ software (downloadable in the Download Area)