Earth Resistance and Loop Impedance RCD Tester HT Italia Speed 418

Code: HT Italia Speed 418


 

Datasheet PDF, 0.31 Mb

Description

  • Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
  • Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
  • Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
  • Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
  • Prospective short circuit current
  • Phase sequence indication
  • Activation of measurements (with optio-nal remote probe PR400)
  • Help on line on the display
  • Storage of results
  • Optical/USB interface for connection to PC
  • Safety EN61010-1 EN61010-1 Measurement category CAT III 265VCAT III 265V
 

Standard accessories

  • 3-terminal cable with SHUKO plug C2033X
  • Carrying bag BORSA75N
  • ISO9000 calibration certificate
  • User manual on CD-ROM
  • Quick reference guide
 

Recommended options

  • PC Windows software + optical / USB cable TOPVIEW2006
  • Set of 3 cables + 3 alligator clips + 1 test leads UNIVERSALKIT
  • NOCANBA
  • Remote probe PR400
  • Hands-free kit SP-0400
  • Magnetic adapter 606-IECN
  • Safety flexible alligator clip 6007-IEC#
 

More products HT ITALIA

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

DIGITAL CURRENT CLAMP METERS HT ITALIA

• DC/AC/AC+DC TRMS current
• DC/AC/Ac+DC TRMS Voltage
• Peak of AC current and AC voltage

 

THT600 INFRARED CAMERA 384X288PXL

• IR Resolution 384x288 pxl
• Temperature range -20° ÷ 650°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 17° x 12.7°

 

HANDHELD DIGITAL MEGOHMMETER INSULATION & CONTINUITY 4 GOHM 1000V HT ITALIA M70

• Insulation with test voltage 250, 500, 1000VDC
• Up to 4Gohm measurement range
• Automatic discharge of device under test
• LOCK feature for continuous measurements
• Programmable timer up to 60s
• Continuity of earth conductors with test current of 200mA
• A/DC voltage up to 600V
• Resistance and continuity test with buzzer

 

SAFETY TESTER FOR PHOTOVOLTAIC SYSTEMS HT PVCHECK

• Safety test of PV installation
• Continuity test on protective conductors with 200mA
• Insulation test with test voltage of 250, 500, 1000VDC
• DC voltage
• DC current
• DC Power
• Solar irradiation [W/m2] with reference cell

 

PV-ISOTEST TESTER FOR CHECKING ELECTRIC SAFETY OF PHOTOVOLTAIC PANELS WITH GROUD FAULT LOCATION GFL FUNCTION

• Insulation measurement up to 1,500V DC even on live systems
• Localization of the faulty module through the new GFL function
• Continuity of the protective conductor with 200mA

 

PVCHECKS-PRO COMMISSIONING TESTER FOR PV SYSTEM UP TO 1500V / 40A

• Continuity of protective conductors with 200mA
• Polarity
• Open circuit voltage Voc of PV modules and strings 1500V
• Short circuit current Isc on PV modules and strings 40A
• PV string/field insulation with test voltage 250, 500, 1000, 1500VDC

 

THT80 COMPACT INFRARED THERMOGRAPHY CAMERA 120X90PXL

• IR Resolution 120 x 90 pxl
• Temperature range -20° ÷ 550°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 50° x 37°

 

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

SINGLE/ THREE-PHASE NETWORK AC VOLTAGE DATA LOGGER HT ITALIA XL423/ XL424

• TRMS AC Voltage measure up to 600V
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software