Single/ Three-Phase Network AC Current Data Logger HT Italia XL421/ XL422

Code: HT Italia XL421/ XL422


 

Datasheet PDF, 0.56 Mb

Description

  • TRMS AC current measure up to 2500A
  • Recording with sampling programmable period
  • Manual activation of recording
  • Low battery indication
  • LED indication of any operation
  • RS-232 interface
  • Data maintaining without batteries.
  • Programming with DATALINK software
 

Standard accessories

  • XL421: HTFLEX33DL 3000A flexible clamp integrated
  • XL422: HTFLEX33DL built-in 3000A AC flexible clamp, 3 pcs

 

  • Adhesive Velcro for fixing
  • DATALINK: Windows software
  • C2004: RS-232 serial cable
  • BORSA2000: carrying bag
  • User manual
 

More products HT ITALIA

FULLTEST3 MULTIFUNCTION TESTER FOR SAFETY OF MACHINERY IEC/EN60204-1 AND LOW VOLTAGE SWITCHGEARS AND CONTROLGEARS IEC/EN61439-1-2

• IEC/EN60204-1 and IEC/EN61439-1-2 Measuments
• Continuity of protective circuit with 200mA
• Continuity of protective circuit with I>10A, V<12V
• Continuity of protective circuit with I>25A, V<12V
• Insulation with test voltages 100, 250, 500, 1000VDC
• Dielectric strength with voltage programmable from 250V to 5100VAC

 

HANDHELD DIGITAL MEGOHMMETER INSULATION & CONTINUITY 4 GOHM 1000V HT ITALIA M70

• Insulation with test voltage 250, 500, 1000VDC
• Up to 4Gohm measurement range
• Automatic discharge of device under test
• LOCK feature for continuous measurements
• Programmable timer up to 60s
• Continuity of earth conductors with test current of 200mA
• A/DC voltage up to 600V
• Resistance and continuity test with buzzer

 

EARTH GROUNDING RESISTANCE MULTIMETER HT ITALIA M71

• 3-wire Earth Resistance
• 2-wire Earth Resistance
• Measurement range up to 50kOhm
• Calibration of test cables
• Automatic regulation of noise voltage disturbances

 

HT PQA924 CLASS S POWER QUALITY AND ENERGY ANALYZER

• AC voltage in single-phase and three-phase systems
• AC current in single-phase and three-phase systems
• Cosphi, Power Factor, K-Factor
• Voltage unbalance
• Flicker
• Active, Reactive, and Apparent power/energy
• Voltage and current harmonic amplitude and phase up to the 63rd order with THD% calculation

 

SINGLE/ THREE-PHASE NETWORK AC VOLTAGE DATA LOGGER HT ITALIA XL423/ XL424

• TRMS AC Voltage measure up to 600V
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

AUDIO ANALYZER CLASS 1 HT ITALIA HT155/ HT157

• Measuring range 25-140dB
• "Peak", "Fast", "Slow" and "Impulse" integrations
• "A", "C" and "Z (linear)" frequency weighting
• "Peak+" and "Peak-" measurement in C weighting
• Spectral analysis with octave and 1/3 octave digital filter (HT157)
• Class 1 portable calibrator
• Mini-USB output for connection to PC

 

HT I-V500W PHOTOVOLTAIC SYSTEM ANALYZER WITH I-V CURVE TRACER 1500V 15A

• I-V Curve Tracer for maintenance and troubleshooting of photovoltaic systems.
• Measurement of I-V Curve of one or more modules or of one whole string up to 1500V/10A
• Measurement of open-circuit voltage and short-circuit current Voc/Isc
• Database of 30.000 selectable photovoltaic modules

 

HT SOLAR I-VE MULTIFUNCTION I-V CURVE TRACER FOR PHOTOVOLTAIC SYSTEMS

• 1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
• Measurement of efficiency of a single-phase photovoltaic system
• Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
• Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
• Measurement of short-circuit current of a module or of a string (ISC) 15A

 

THREE-PHASE POWER QUALITY ANALYZER HT PQA820

• 3 system types: Single-phase, three-phase 3-wire, three-phase 4-wire.
•  Configurable directly from Smartphone or Tablet.
•  Fast trips and detailed zoom of all sizes.
•  Real Time.
•  Energy consumption logger.
•  383 parameters can be displayed simultaneously.
•  Technology and absolute simplicity.
•  Harmonics Jump function.

 

PVCHECKS-ONE COMMISSIONING TESTER FOR PV SYSTEM UP TO 1000V / 30A

• Continuity of protective circuit with 200mA
• Polarity
• Open circuit voltage Voc of PV modules and strings 1000V
• Short circuit current Isc on PV modules and strings 30A
• PV string/field insulation with test voltage 250, 500, 1000VDC
• Measurement of polarization index P.I.
• Dielectric absorption ratio D.A.R
• GFL function to locate the fault position in the string
• Measurement category CAT III 1000V
• OPT function for insulation testing on PV strings in the presence of MLPE