Professional Multimeter Cable Verifier for LAN VDE checking HT Italia M75

Code: HT Italia M75


 

Datasheet PDF, 0.42 Mb

Description

DMM SECTION

  • DC Voltage
  • AC TRMS Voltage
  • AC TRMS Current with External Clamp
  • AC TRMS Leakage current with external clamp (optional)
  • DC Current
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with External Clamp
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function

 

SAFETY TEST SECTION

  • Continuity test of protective conductors with 200mA
  • Insulation Resistance measurement with 500VDC
  • Trip-out time of RCDs type AC Standard with test current of 30mA, 30x5mA, 100mA, 300mA
  • Global Earth Resistance without RCD tripping
  • Phase sequence indication at 1 or 2 wires
  • Phase coincidence indication at 1 or 2 wires
  • Leakage current (with HT96U optional clamp + NOCANBA connector)
  • AUTOTEST function: automatic sequence test of Global Earth Resistance + RDC test + Insulation test with OK / NOT OK indications LAN SECTION
  • Test executed on twisted pairs cables UTP and STP with RJ45 connector
  • Wire mapping control of following wrong conditions:
  • OPEN, SHORT, CROSS, REVERSE, SPLIT, MISWIRE message at display
  • Quickly selection of cables pairs
  • Automatic detection of remote control units (from #1 to #8)
  • AutoPowerOFF
  • Low battery indication
 

Standard accessories

  • HT4003: 400A AC clamps
  • C2075: two safety banana + Shuko plug cable
  • KIT0075: kit of 2 Test leads + 2 alligator clips
  • N° 2 Remote identifier # 1, # 2
  • N° 3 Patch cables, 30 cm, RJ45  RJ45 connectors
  • BORSA75: Carrying bag
  • Calibration Certificate ISO9000
  • Instruction manual
  • Warranty card
 

Recommended options

  • HT96U: leakage current clamp 1-100-1000A/1V 54mm max diameter
  • NOCANBA: adaptor for connection HT96U clamp
  • REM38: N° 6 Remote unit # 3, # 4, # 5, # 6, # 7, # 8
  • REM3: remote unit #3 + connection cable RJ45-RJ45
  • REM4: remote unit #4 + connection cable RJ45-RJ45
  • REM5: remote unit #5 + connection cable RJ45-RJ45
  • REM6: remote unit #6 + connection cable RJ45-RJ45
  • REM7: remote unit #7 + connection cable RJ45-RJ45
  • REM8: remote unit #8 + connection cable RJ45-RJ45
 

More products HT

DIGITAL PROGRAMMABLE PROFESSIONAL MEGOHMMETER 10TOHM 5KV HT ITALIA HT7051

• Insulation resistance measurement with test voltage up to 5kVDC
• Measurement range up to 10Tohm
• Polarization Index (P.I.) measurement
• Dielectric Absorption Ratio (D.A.R) measurement
• RS-232 interface for PC connection
• Rechargeable internal battery

 

HT I-V500W PHOTOVOLTAIC SYSTEM ANALYZER WITH I-V CURVE TRACER 1500V 15A

• I-V Curve Tracer for maintenance and troubleshooting of photovoltaic systems.
• Measurement of I-V Curve of one or more modules or of one whole string up to 1500V/10A
• Measurement of open-circuit voltage and short-circuit current Voc/Isc
• Database of 30.000 selectable photovoltaic modules

 

GSC60 MULTIFUNCTION TESTER FOR ELECTRICAL SAFETY TESTS AND POWER QUALITY ANALYSIS

• LECTRICAL SAFETY TESTING CEI 64-8
• Earth Resistance with voltammetric method with 2 or 3 points in TT, TN and IT systems
• NETWORK AND ENERGY CONSUMPTION ANALYSIS
• Measurement and recording of electrical parameters
• Voltages, Currents, Powers, Energies, cosphi, etc. in Single-phase and Three-phase systems

 

PV-ISOTEST TESTER FOR CHECKING ELECTRIC SAFETY OF PHOTOVOLTAIC PANELS WITH GROUD FAULT LOCATION GFL FUNCTION

• Insulation measurement up to 1,500V DC even on live systems
• Localization of the faulty module through the new GFL function
• Continuity of the protective conductor with 200mA

 

HT8100 PROFESSIONAL PROCESS CALIBRATOR WITH MULTIMETER FUNCTIONS

• TRMS
• AC/DC voltage 1000V AC+DC
• AC/DC current 1A AC+DC
• DC 4-20mA current measurement
• DC 0-10V voltage measurement
• DC 4-20mA current generation

 

DIGITAL PROCESS CALIBRATOR PORTABLE MULTIMETER HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

PVCHECKS-ONE COMMISSIONING TESTER FOR PV SYSTEM UP TO 1000V / 30A

• Continuity of protective circuit with 200mA
• Polarity
• Open circuit voltage Voc of PV modules and strings 1000V
• Short circuit current Isc on PV modules and strings 30A
• PV string/field insulation with test voltage 250, 500, 1000VDC
• Measurement of polarization index P.I.
• Dielectric absorption ratio D.A.R
• GFL function to locate the fault position in the string
• Measurement category CAT III 1000V
• OPT function for insulation testing on PV strings in the presence of MLPE

 

HANDHELD DIGITAL SOUNDMETER WITH CALIBRATOR HT ITALIA HT154

• Measure of Sound Level Pressure (SPL)
• 0.1dB resolution
• Selection manual of range
• MAX/MIN display
• Frequency Weighting A and C
• Integration FAST/SLOW

 

I-V600 ADVANCED MULTIFUNCTION INSTRUMENT FOR I-V CURVE MEASUREMENTS UP TO 1500V AND 40A

• I-V curve tracing of mono-facial and bi-facial PV modules and strings up to 1500V/40A according to IEC/EN60891
• SOLAR03 remote unit with Bluetooth connection
• Up to 3 reference cells to measure front-side and rear-side radiation according to IEC TS 60904-1-2
• Database of over 30,000 photovoltaic modules manageable via connection with the new HT AGORÀ software (downloadable in the Download Area)

 

DIGITAL CURRENT CLAMP METERS HT ITALIA

• DC/AC/AC+DC TRMS current
• DC/AC/Ac+DC TRMS Voltage
• Peak of AC current and AC voltage