DMM SECTION

  • DC Voltage
  • AC TRMS Voltage
  • AC TRMS Current with External Clamp
  • AC TRMS Leakage current with external clamp (optional)
  • DC Current
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with External Clamp
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function

 

SAFETY TEST SECTION

  • Continuity test of protective conductors with 200mA
  • Insulation Resistance measurement with 500VDC
  • Trip-out time of RCDs type AC Standard with test current of 30mA, 30x5mA, 100mA, 300mA
  • Global Earth Resistance without RCD tripping
  • Phase sequence indication at 1 or 2 wires
  • Phase coincidence indication at 1 or 2 wires
  • Leakage current (with HT96U optional clamp + NOCANBA connector)
  • AUTOTEST function: automatic sequence test of Global Earth Resistance + RDC test + Insulation test with OK / NOT OK indications LAN SECTION
  • Test executed on twisted pairs cables UTP and STP with RJ45 connector
  • Wire mapping control of following wrong conditions:
  • OPEN, SHORT, CROSS, REVERSE, SPLIT, MISWIRE message at display
  • Quickly selection of cables pairs
  • Automatic detection of remote control units (from #1 to #8)
  • AutoPowerOFF
  • Low battery indication
 

Standard accessories

  • HT4003: 400A AC clamps
  • C2075: two safety banana + Shuko plug cable
  • KIT0075: kit of 2 Test leads + 2 alligator clips
  • N° 2 Remote identifier # 1, # 2
  • N° 3 Patch cables, 30 cm, RJ45  RJ45 connectors
  • BORSA75: Carrying bag
  • Calibration Certificate ISO9000
  • Instruction manual
  • Warranty card
 

Recommended options

  • HT96U: leakage current clamp 1-100-1000A/1V 54mm max diameter
  • NOCANBA: adaptor for connection HT96U clamp
  • REM38: N° 6 Remote unit # 3, # 4, # 5, # 6, # 7, # 8
  • REM3: remote unit #3 + connection cable RJ45-RJ45
  • REM4: remote unit #4 + connection cable RJ45-RJ45
  • REM5: remote unit #5 + connection cable RJ45-RJ45
  • REM6: remote unit #6 + connection cable RJ45-RJ45
  • REM7: remote unit #7 + connection cable RJ45-RJ45
  • REM8: remote unit #8 + connection cable RJ45-RJ45
 

More products HT

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

HT GSC60 MULTIFUNCTION ELECTRICAL INSTALLATION TESTER WITH POWER QUALITY ANALYSIS

• Insulation with voltage 50, 100, 250, 500, 1000VDC
• Three-phase Power quality and Energy consumption analysis
• 632 parameters can be recorded for over two months
• Voltage/current vector diagram
• Voltage/current waveforms
• Tables or histograms of Harmonics and THD%
• Integrated WiFi connection and compatibility with HTANALYSIS App

 

STEP AND CONTACT VOLTAGE METER WITH TEST CURRENT UP TO 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

INSULATION CONTINUITY MEGOHMMETER AND DIGITAL MULTIMETER HT ITALIA M72

• Insulation Resistance with 250, 500VDC
• Measurement range up to 1GOhm
• Automatic discharging object after test
• Continuity test of protective conductors with 200mA
• DC Voltage
• AC TRMS Voltage

 

HT8100 PROFESSIONAL PROCESS CALIBRATOR WITH MULTIMETER FUNCTIONS

• TRMS
• AC/DC voltage 1000V AC+DC
• AC/DC current 1A AC+DC
• DC 4-20mA current measurement
• DC 0-10V voltage measurement
• DC 4-20mA current generation

 

FULLTEST3 MULTIFUNCTION TESTER FOR SAFETY OF MACHINERY IEC/EN60204-1 AND LOW VOLTAGE SWITCHGEARS AND CONTROLGEARS IEC/EN61439-1-2

• IEC/EN60204-1 and IEC/EN61439-1-2 Measuments
• Continuity of protective circuit with 200mA
• Continuity of protective circuit with I>10A, V<12V
• Continuity of protective circuit with I>25A, V<12V
• Insulation with test voltages 100, 250, 500, 1000VDC
• Dielectric strength with voltage programmable from 250V to 5100VAC

 

HT I-V500W PHOTOVOLTAIC SYSTEM ANALYZER WITH I-V CURVE TRACER 1500V 15A

• I-V Curve Tracer for maintenance and troubleshooting of photovoltaic systems.
• Measurement of I-V Curve of one or more modules or of one whole string up to 1500V/10A
• Measurement of open-circuit voltage and short-circuit current Voc/Isc
• Database of 30.000 selectable photovoltaic modules

 

ENVIRONEMENTAL MULTIFUNCTION TESTERS HT ITALIA

• Air temperature (°C/°F)
• Air relative humidity (%RH)
• Air speed (m/S)
• Air volume (m3/s)
• Capacity measurements (kW)
• Temperature dew point measurement

 

HANDHELD DIGITAL SOUNDMETER WITH CALIBRATOR HT ITALIA HT154

• Measure of Sound Level Pressure (SPL)
• 0.1dB resolution
• Selection manual of range
• MAX/MIN display
• Frequency Weighting A and C
• Integration FAST/SLOW

 

POWER ANALYZER CURRENT CLAMP METER HT ITALIA HT9022

• DC, AC + DC TRMS current up to 1000A
• DC, AC + DC TRMS voltage up to 1000V
• Resistance and continuity test
• Active, Reactive, Apparent power on Single/Three phase systems
• Active, Reactive energy on Single/Three phase systems
• Power Factor on Single/Three phase systems
• Harmonic voltage/current up to 25th with THD% calculation