MACROEVTEST Multifunction Tester with Power Analysis and electric vehicle charging stations EVSE

Code: MACROEVTEST


 

Datasheet PDF, 0.77 Mb
   

Description

MACROEVTEST
Multifunction instrument for electrical installation safety testing, power quality analysis and EVSE safety testing

Multifunction instrument for electrical installation safety testing, power quality analysis and EVSE safety testing
MACROEVTEST is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, MACROEVTEST also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity. MACROEVTEST also allows measuring and saving environmental parameters (illuminance, temperature), leakage current and electric quantities such as voltage, current, power factor, power and harmonics on single-phase systems.
MACROEVTEST is provided with the innovative AUTO function: by selecting this function and only setting the value of RCD current, COMBI521 carries out tests of overall earth resistance, RCD tripping time and insulation resistance in a sequence. At the end of the test, the device shows all results with the indication of compliance or non-compliance with the standards with simple OK or NOT OK symbols.
The internal memory allows saving the measures and subsequently transfer them onto the PC through the optical/USB connection. Thanks to the brand new HTAnalysis App, free to download for iOS and Android systems, MACROEVTEST is capable of transferring measured and recorded data onto tablets and smartphones, thus giving the operator the possibility to customize and share through HTCloud the result of their tests.
 

AUTOMATIC EVSE SAFETY TEST
Check of the output voltage value
Continuity check of the protective conductor
Insulation resistance measurement
Check of the status:
                                        - Standby (status A)
                                        - Vehicle detected (status B)
                                        - Mechanical interlock verification (status B)
                                        - Ready (charging) (status C) with ventilation (status D)
                                        - Fault simulation on the protective conductor (fault PE)
                                        - Fault on CP signal (fault E)
Global earth resistance measurement
Measurement of RCD tripping time (type A, type B and type DD 6ma)
 

ELECTRICAL INSTALLATION SAFETY TEST
AUTOMATIC test (no-trip ground resistance, RCD tripping time, insulation resistance) in a sequence
Continuity of protective conductors with 200mA
Insulation resistance up to 1000V, with dielectric absorption ratio D.A.R. and polarization index P.I.
Polarity test
Type A, AC, B General and Selective RCD tripping time and current
Line/Fault impedance, Phase-Phase, Phase-Neutral, Phase-PE (also at high resolution with optional accessory IMP57)
Coordination of MCBs and fuses
Global earth resistance
Phase sequence and conformity measurement
Measurement of leakage current
Measurement of electrical parameters in single-phase installations (V, A, W, VAR, VA, PF)
Measurement of environmental parameters through external probes (HT52/05 and HT53/05)
 

GENERAL
Internal memory and PC connection
Wi-Fi connection to Android and iOS smartphones and tablets

Functions
Sequence of tests for the verification of electric columnswith EV-TEST100 adapter
TRMS 
Insulation with test voltages 100, 250, 500, 1000VDC 
Continuity of protective conductors with 200mA 
Continuity of protective conductors with 10AWith optional accessory EQUITEST
Tripping time and current of RCDs type B, A, AC Standard, Selective and Delayed up to 1A 
Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10AWith optional accessory RCDX10
Non-trip earth resistance 
Earth resistance by voltammetric method 
Resistance of the single earth rods with clampWith optional accessory T2100
Ground resistivity by 4-wire method 
Loop/Line impedance, Phase-Phase, Phase-Neutral, Phase-PEWith optional accessory IMP57
Measurement of percentage voltage drop on the line 
AUTO test (Non-trip ground resistance, RCD, Insulation) in sequence 
Contact voltage 
Phase sequence 
Leakage current with optional clamp meter 
Measurement of Voltage, Current, Active, Reactive, Apparent Power(1)
Measurement of Cosphi, Power Factor(1)
Voltage and current harmonics up to the 25th and THD%25ª
Protection categoryCAT IV 300V
Measurement of environmental parameters (°C,°F, %RH, Lux) 
Test with remote leadPR400
Help on line on the display 
Internal memory for measured data saving 
Optical/USB serial port for PC connection 
Integrated WiFi connection and compatibil
 

Standard accessories

Accessories provided
› C2033X 
Three wire cable with Schuko plug
› UNIVERSALKITG3 
Set of 4 cables + 4 alligator clips + 3 test leads
› KITTERRNE 
Set of 4 cables + 4 earth probes + carrying bag
› PT400 
Touchscreen stylus (included inside meter)
› PR400 
Remote START/STOP switch probe
› ZEROLOOP 
Loop zero adapter
› EV-TEST100 
EVSE test adapter 
› RCDX10 
Accessory to test earth leakage relay

› SP-5100 
Carrying straps
› TOPVIEW2006 
PC Windows software + optical/USB connection 
cable (order code: C2006)
› VA507 
Hard carrying case
› YABAT0003000 
Rechargeable battery NiMH, 1.2V, type AA 6 pcs
› YABAT0004001 
External charger
› YAMUM0058HT0 
Quick reference guide
› YAMUM0057HT0 
User’s manual on CD-ROM
› ISO calibration report
 

Recommended options

Optional accessories
› HT4005K 
Standard clamp with 200A/1V AC full scale
› HT96U 
Standard clamp with 1/100/1000A full scale
› IMP57  
Accessory for Loop impedance measurement with 
high resolution
› T2100 
Clamp for earth probe resistance measurement
› HT52/05 
Temperature/Humidity probe

› HT53/05 
Illuminance (lux) probe
› BORSA2051 
Carrying bag
› 606-IECN 
Connector with magnetic tip
› 1066-IECN 
Connector for extension of  banana cables 4mm
 

More products HT ITALIA

I-V600 ADVANCED MULTIFUNCTION INSTRUMENT FOR I-V CURVE MEASUREMENTS UP TO 1500V AND 40A

• I-V curve tracing of mono-facial and bi-facial PV modules and strings up to 1500V/40A according to IEC/EN60891
• SOLAR03 remote unit with Bluetooth connection
• Up to 3 reference cells to measure front-side and rear-side radiation according to IEC TS 60904-1-2
• Database of over 30,000 photovoltaic modules manageable via connection with the new HT AGORÀ software (downloadable in the Download Area)

 

STEP AND CONTACT VOLTAGE METER WITH TEST CURRENT UP TO 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

HT8100 PROFESSIONAL PROCESS CALIBRATOR WITH MULTIMETER FUNCTIONS

• TRMS
• AC/DC voltage 1000V AC+DC
• AC/DC current 1A AC+DC
• DC 4-20mA current measurement
• DC 0-10V voltage measurement
• DC 4-20mA current generation

 

DIGITAL PORTABLE MULTIMETERS HT ITALIA

• DC Voltage
• AC TRMS Voltage
• DC Current
• AC TRMS Current

 

SINGLE/ THREE-PHASE NETWORK AC VOLTAGE DATA LOGGER HT ITALIA XL423/ XL424

• TRMS AC Voltage measure up to 600V
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

DIGITAL PROCESS CALIBRATOR PORTABLE MULTIMETER HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

HT9025T CURRENT CLAMP METER WITH INFRARD CAMERA AND 1500V DC

• TRMS
• Current measuring range 1000A
• AC/DC current AC+DC
• AC/DC voltage 1000VAC/1500VDC
• IR Resolution 120 x 120 pxl

 

ENVIRONEMENTAL MULTIFUNCTION TESTERS HT ITALIA

• Air temperature (°C/°F)
• Air relative humidity (%RH)
• Air speed (m/S)
• Air volume (m3/s)
• Capacity measurements (kW)
• Temperature dew point measurement

 

DIGITAL MULTIFUNCTION VDE MULTIMETER HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution