PVCHECKs-PRO Commissioning tester for PV system up to 1500V / 40A

Code: PVCHECKs-PRO HV00PVPR


 

Datasheet PDF, 1.25 Mb
   

Description

PVCHECKs-PRO
Commissioning tester for PV system up to 1500V / 40A

PVCHECKs-PRO

Multifunction commissioning tester up to 1500V / 40A capable of taking the following measurements:
• Insulation measurement on PV modules/strings/fields up to 1500VDC (with PI and DAR calculation)
• Open circuit voltage Voc up to 1500V in accordance with IEC/EN62446
• Short circuit current Isc up to 40A in accordance with IEC/EN62446
• Continuity of protective conductors with 200mA
• Polarity
• GFL function for fault finding on strings and PV modules
• Tests on single-facial and bi-facial modules
• Automatic acquisition of the cell calibration value (by using suitable cells)
• OPT function for insulation testing on MLPE-equipped PV strings (including optimizers and RSDs), allowing measurements to be performed without the need to disconnect the MLPE devices*
*Soon available with the new update.
 

PVCHECKs-PRO is a commissioning tester designed to take all safety measurements and verifications of PV installations in accordance with IEC/EN62446. By a single GO-key stroke PVCHECKs-PRO performs all commissioning tests. Thanks to the seamless mode, PVCHECKs-PRO is able to test in sequence all strings of a combiner box by a single GO-key stroke. Finally, the GFL - Ground Fault Locator detects the precise position of the lack of insulation, speeding the troubleshooting.

Functions
Continuity of protective conductors with 200mA 
Polarity 
Open circuit voltage Voc of PV modules and strings1500V
Short circuit current Isc on PV modules and strings40A
PV string/field insulation with test voltage 250, 500, 1000, 1500VDC 
Use of SOLAR-03 remote unit with Bluetooth connection 
Measurement of direct (front side) irradiation with reference cellwith SOLAR03 remote unit (optional accessory)
Temperature measurement of cell and environmentwith SOLAR03 remote unit (optional accessory)
Measurement of polarization index P.I. 
Dielectric absorption ratio D.A.R 
OPT function for insulation testing on PV strings in the presence of MLPE devices such as optimizers and RSDs, without the need to disconnect them from the modulesComing soon with the new update
GFL function to locate the fault position in the string 
Measurement categoryCAT III 1000V AC, CAT III 1500VDC
Backlit LCD display 
Internal memory999 Locations
Integrated WiFi connection and compatibility with HTANALYSIS App 
Optical/USB serial port for PC connection 
Custom management of internal PV module database 
Auto power off 
Help on line on the display 
Size (LxWx H) (mm)235x165x75
Weight in grams (batteries included)1200
 

Standard accessories

STANDARD ACCESSORIES
KIT3PRO15 Set of 2 cables banana + 2 integrated alligator clips Blue/Green
KITPCMC415 Set of 2 cables MC4/banana + 2 adapters MC4/alligator clips, 3m, Red/Black
SP-5100 Set of straps for shoulder instrument use
C2006 Optics/USB connection cable
YABAT0003000 Rechargeable battery type AA NiMH, 1.2V (6 pc)
YABAT0004001 External battery charger
VA507 Rigid carrying case
Quick start guide
Calibration report
Complete user manual and management software available online
 

Recommended options

OPTIONAL ACCESSORIES
PT305 Temperature probe PT1000
HT305 Photovoltaic cell to measure solar radiation (with fixing bracket)
M304 Mechanical inclinometer to detect the correct solar incidence angle
SOLAR03 Remote unit with 1 temperature input and 3 irradiation inputs (for HT305) complete
with magnetic belt
KITPVPROEXT20 2 extension cables banana pin - banana jack 20m (red and black)
SP-2002 Strap with magnetic attachment for SOLAR03
KIT2TIPS15 Set of 2 Black/Red leads with MC4 termination
 

More products HT ITALIA

PV-ISOTEST TESTER FOR CHECKING ELECTRIC SAFETY OF PHOTOVOLTAIC PANELS WITH GROUD FAULT LOCATION GFL FUNCTION

• Insulation measurement up to 1,500V DC even on live systems
• Localization of the faulty module through the new GFL function
• Continuity of the protective conductor with 200mA

 

DIGITAL CURRENT CLAMP METERS HT ITALIA

• DC/AC/AC+DC TRMS current
• DC/AC/Ac+DC TRMS Voltage
• Peak of AC current and AC voltage

 

GSC60 MULTIFUNCTION TESTER FOR ELECTRICAL SAFETY TESTS AND POWER QUALITY ANALYSIS

• LECTRICAL SAFETY TESTING CEI 64-8
• Earth Resistance with voltammetric method with 2 or 3 points in TT, TN and IT systems
• NETWORK AND ENERGY CONSUMPTION ANALYSIS
• Measurement and recording of electrical parameters
• Voltages, Currents, Powers, Energies, cosphi, etc. in Single-phase and Three-phase systems

 

HANDHELD DIGITAL MEGOHMMETER INSULATION & CONTINUITY 4 GOHM 1000V HT ITALIA M70

• Insulation with test voltage 250, 500, 1000VDC
• Up to 4Gohm measurement range
• Automatic discharge of device under test
• LOCK feature for continuous measurements
• Programmable timer up to 60s
• Continuity of earth conductors with test current of 200mA
• A/DC voltage up to 600V
• Resistance and continuity test with buzzer

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

HT SOLAR I-VE MULTIFUNCTION I-V CURVE TRACER FOR PHOTOVOLTAIC SYSTEMS

• 1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
• Measurement of efficiency of a single-phase photovoltaic system
• Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
• Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
• Measurement of short-circuit current of a module or of a string (ISC) 15A

 

STEP AND CONTACT VOLTAGE METER WITH TEST CURRENT UP TO 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

HANDHELD DIGITAL SOUNDMETER WITH CALIBRATOR HT ITALIA HT154

• Measure of Sound Level Pressure (SPL)
• 0.1dB resolution
• Selection manual of range
• MAX/MIN display
• Frequency Weighting A and C
• Integration FAST/SLOW

 

SINGLE/ THREE-PHASE NETWORK AC CURRENT DATA LOGGER HT ITALIA XL421/ XL422

• TRMS AC current measure up to 2500A
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

HT9025T CURRENT CLAMP METER WITH INFRARD CAMERA AND 1500V DC

• TRMS
• Current measuring range 1000A
• AC/DC current AC+DC
• AC/DC voltage 1000VAC/1500VDC
• IR Resolution 120 x 120 pxl