PVCHECKs-PRO Commissioning tester for PV system up to 1500V / 40A

Code: PVCHECKs-PRO HV00PVPR


 

Datasheet PDF, 1.25 Mb
   

Description

PVCHECKs-PRO
Commissioning tester for PV system up to 1500V / 40A

PVCHECKs-PRO

Multifunction commissioning tester up to 1500V / 40A capable of taking the following measurements:
• Insulation measurement on PV modules/strings/fields up to 1500VDC (with PI and DAR calculation)
• Open circuit voltage Voc up to 1500V in accordance with IEC/EN62446
• Short circuit current Isc up to 40A in accordance with IEC/EN62446
• Continuity of protective conductors with 200mA
• Polarity
• GFL function for fault finding on strings and PV modules
• Tests on single-facial and bi-facial modules
• Automatic acquisition of the cell calibration value (by using suitable cells)
• OPT function for insulation testing on MLPE-equipped PV strings (including optimizers and RSDs), allowing measurements to be performed without the need to disconnect the MLPE devices*
*Soon available with the new update.
 

PVCHECKs-PRO is a commissioning tester designed to take all safety measurements and verifications of PV installations in accordance with IEC/EN62446. By a single GO-key stroke PVCHECKs-PRO performs all commissioning tests. Thanks to the seamless mode, PVCHECKs-PRO is able to test in sequence all strings of a combiner box by a single GO-key stroke. Finally, the GFL - Ground Fault Locator detects the precise position of the lack of insulation, speeding the troubleshooting.

Functions
Continuity of protective conductors with 200mA 
Polarity 
Open circuit voltage Voc of PV modules and strings1500V
Short circuit current Isc on PV modules and strings40A
PV string/field insulation with test voltage 250, 500, 1000, 1500VDC 
Use of SOLAR-03 remote unit with Bluetooth connection 
Measurement of direct (front side) irradiation with reference cellwith SOLAR03 remote unit (optional accessory)
Temperature measurement of cell and environmentwith SOLAR03 remote unit (optional accessory)
Measurement of polarization index P.I. 
Dielectric absorption ratio D.A.R 
OPT function for insulation testing on PV strings in the presence of MLPE devices such as optimizers and RSDs, without the need to disconnect them from the modulesComing soon with the new update
GFL function to locate the fault position in the string 
Measurement categoryCAT III 1000V AC, CAT III 1500VDC
Backlit LCD display 
Internal memory999 Locations
Integrated WiFi connection and compatibility with HTANALYSIS App 
Optical/USB serial port for PC connection 
Custom management of internal PV module database 
Auto power off 
Help on line on the display 
Size (LxWx H) (mm)235x165x75
Weight in grams (batteries included)1200
 

Standard accessories

STANDARD ACCESSORIES
KIT3PRO15 Set of 2 cables banana + 2 integrated alligator clips Blue/Green
KITPCMC415 Set of 2 cables MC4/banana + 2 adapters MC4/alligator clips, 3m, Red/Black
SP-5100 Set of straps for shoulder instrument use
C2006 Optics/USB connection cable
YABAT0003000 Rechargeable battery type AA NiMH, 1.2V (6 pc)
YABAT0004001 External battery charger
VA507 Rigid carrying case
Quick start guide
Calibration report
Complete user manual and management software available online
 

Recommended options

OPTIONAL ACCESSORIES
PT305 Temperature probe PT1000
HT305 Photovoltaic cell to measure solar radiation (with fixing bracket)
M304 Mechanical inclinometer to detect the correct solar incidence angle
SOLAR03 Remote unit with 1 temperature input and 3 irradiation inputs (for HT305) complete
with magnetic belt
KITPVPROEXT20 2 extension cables banana pin - banana jack 20m (red and black)
SP-2002 Strap with magnetic attachment for SOLAR03
KIT2TIPS15 Set of 2 Black/Red leads with MC4 termination
 

More products HT ITALIA

DIGITAL PROCESS CALIBRATOR PORTABLE MULTIMETER HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

THT600 INFRARED CAMERA 384X288PXL

• IR Resolution 384x288 pxl
• Temperature range -20° ÷ 650°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 17° x 12.7°

 

GSC60 MULTIFUNCTION TESTER FOR ELECTRICAL SAFETY TESTS AND POWER QUALITY ANALYSIS

• LECTRICAL SAFETY TESTING CEI 64-8
• Earth Resistance with voltammetric method with 2 or 3 points in TT, TN and IT systems
• NETWORK AND ENERGY CONSUMPTION ANALYSIS
• Measurement and recording of electrical parameters
• Voltages, Currents, Powers, Energies, cosphi, etc. in Single-phase and Three-phase systems

 

HT I-V500W PHOTOVOLTAIC SYSTEM ANALYZER WITH I-V CURVE TRACER 1500V 15A

• I-V Curve Tracer for maintenance and troubleshooting of photovoltaic systems.
• Measurement of I-V Curve of one or more modules or of one whole string up to 1500V/10A
• Measurement of open-circuit voltage and short-circuit current Voc/Isc
• Database of 30.000 selectable photovoltaic modules

 

HT9025T CURRENT CLAMP METER WITH INFRARD CAMERA AND 1500V DC

• TRMS
• Current measuring range 1000A
• AC/DC current AC+DC
• AC/DC voltage 1000VAC/1500VDC
• IR Resolution 120 x 120 pxl

 

THT80 COMPACT INFRARED THERMOGRAPHY CAMERA 120X90PXL

• IR Resolution 120 x 90 pxl
• Temperature range -20° ÷ 550°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 50° x 37°

 

I-V600 ADVANCED MULTIFUNCTION INSTRUMENT FOR I-V CURVE MEASUREMENTS UP TO 1500V AND 40A

• I-V curve tracing of mono-facial and bi-facial PV modules and strings up to 1500V/40A according to IEC/EN60891
• SOLAR03 remote unit with Bluetooth connection
• Up to 3 reference cells to measure front-side and rear-side radiation according to IEC TS 60904-1-2
• Database of over 30,000 photovoltaic modules manageable via connection with the new HT AGORÀ software (downloadable in the Download Area)

 

MACROEVTEST MULTIFUNCTION TESTER WITH POWER ANALYSIS AND ELECTRIC VEHICLE CHARGING STATIONS EVSE

• Multifunction instrument for electrical installation safety testing
• power quality analysis
• EVSE safety testing
• MACROEVTEST is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards

 

SAFETY TESTER FOR PHOTOVOLTAIC SYSTEMS HT PVCHECK

• Safety test of PV installation
• Continuity test on protective conductors with 200mA
• Insulation test with test voltage of 250, 500, 1000VDC
• DC voltage
• DC current
• DC Power
• Solar irradiation [W/m2] with reference cell

 

DIGITAL MULTIFUNCTION VDE MULTIMETER HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution