Safety Tester for Photovoltaic Systems HT PVCHECK

Code: HT PVCHECK


 

Datasheet PDF, 0.12 Mb

Description

Multifunction instrument to check safety, parameters and performance of a PV plant

 

 

The multifunction instrument PVCHECK allows prompt and safe electrical checks required for a PV system (section DC) as well as controls on working of  modules / strings in accordance with IEC/EN62446 guidelines. PVCHECK verifies the  continuity of the protective conductors (and the associated connections) and executes insulation resistance measurement of the active conductors on a module, a string or a photovoltaic field in accordance with the requirements of IEC/EN62446, without the need of short-circuiting the positive and negative terminals. PVCHECK allows verification of  a PV string's working in accordance with the requirements of IEC/EN62446 by measuring the open circuit voltage and short-circuit current under operating conditions and reporting the results to STC (by means of radiation measurement). It provides an immediate outcome for both absolute measurements and for measurements compared  with the previously tested PV strings.
PVCHECK also allows carrying out performance analysis of PV array (DC) under operating conditions (connected to the inverter) providing an indication of the power generated and the efficiency of the field as specified by IEC/EN62446.

 

  • Safety test of PV installation
  • Continuity test on protective conductors with 200mA
  • Insulation test with test voltage of 250, 500, 1000VDC
  • DC voltage
  • DC current
  • DC Power
  • Solar irradiation [W/m2] with reference cell
  • Environmental  and module temperature by means of PT1000 probe
  • SOLAR-02: remote unit for irradiance and temperature measurements (RF connection).
  • Recording of PV plant parameters (DC side) with programmable IP (5s � 60min)
  • Use of PDC compensation ratios according to environmental and module temperature
  • Use of relationship to maximize the DC efficiency
  • Outcome OK/NO
  • Check of PV string's working
  • Measurement of open circuit voltage up to 1000V DC
  • Measurement of short circuit current up to 10A DC
  • Measurement of temperature, automatic or by means of  PT1000 probe
  • Measurement of solar radiation [W/m2] with reference cell
  • Mechanical inclinometer for the detection of solar radiation incidence angle
  • Comparison with standard conditions (STC 1000 W/m2, 25�C)
  • Outcome of testing: OK / NO
  • Database to manage up to 30 types of photovoltaic modules
  • Internal memory for data saving
  • Optical/USB port for PC connection
  • Help on line on display

 

 

Standards

EMC 2004/108/CE Directive
CE MARK
IEC/EN 61010-032
IEC/EN 61010-1
IEC/EN61557-1
IEC/EN61557-2
IEC/EN61557-4
IEC/EN62446
LVD 2006/95/CE Directive

 

Standard accessories

STANDARD

  • KITGSC4 : Set 4 cables + 4 alligator clips
  • KITPCMC3 : Set of 2 multi-contact one wire for MC3 connectors
  • KITPCMC4 : Set 2 multi-contact one wire for MC4 connectors
  • HT4004 : Standard clamp for  DC current up to 100A
  • TOPVIEW2006 : Windows software + optical/USB cable C2006
  • BORSA2051 : Soft carrying bag
  • User manual on CD-ROM
  • Quick reference guide
  • ISO9000 calibration certificate
 

Recommended options

  • SOLAR-02 : Remote unit for irradiance/temperature
  • HT304N : Reference cell for radiation measurements
  • PT300N : PT1000 probe for cell temperature measurement
  • M304 : Mechanical inclinometer
  • SP-0400 : Set of straps for use of meter on neck
 

More products HT ITALIA

GSC60 MULTIFUNCTION TESTER FOR ELECTRICAL SAFETY TESTS AND POWER QUALITY ANALYSIS

• LECTRICAL SAFETY TESTING CEI 64-8
• Earth Resistance with voltammetric method with 2 or 3 points in TT, TN and IT systems
• NETWORK AND ENERGY CONSUMPTION ANALYSIS
• Measurement and recording of electrical parameters
• Voltages, Currents, Powers, Energies, cosphi, etc. in Single-phase and Three-phase systems

 

AUDIO ANALYZER CLASS 1 HT ITALIA HT155/ HT157

• Measuring range 25-140dB
• "Peak", "Fast", "Slow" and "Impulse" integrations
• "A", "C" and "Z (linear)" frequency weighting
• "Peak+" and "Peak-" measurement in C weighting
• Spectral analysis with octave and 1/3 octave digital filter (HT157)
• Class 1 portable calibrator
• Mini-USB output for connection to PC

 

MACROEVTEST MULTIFUNCTION TESTER WITH POWER ANALYSIS AND ELECTRIC VEHICLE CHARGING STATIONS EVSE

• Multifunction instrument for electrical installation safety testing
• power quality analysis
• EVSE safety testing
• MACROEVTEST is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards

 

FULLTEST3 MULTIFUNCTION TESTER FOR SAFETY OF MACHINERY IEC/EN60204-1 AND LOW VOLTAGE SWITCHGEARS AND CONTROLGEARS IEC/EN61439-1-2

• IEC/EN60204-1 and IEC/EN61439-1-2 Measuments
• Continuity of protective circuit with 200mA
• Continuity of protective circuit with I>10A, V<12V
• Continuity of protective circuit with I>25A, V<12V
• Insulation with test voltages 100, 250, 500, 1000VDC
• Dielectric strength with voltage programmable from 250V to 5100VAC

 

THT600 INFRARED CAMERA 384X288PXL

• IR Resolution 384x288 pxl
• Temperature range -20° ÷ 650°C
• Image frequency 50Hz
• Thermal sensitivity / NETD <0.05°C @ 30°C / 50mK
• Field of view (FOV) 17° x 12.7°

 

PVCHECKS-ONE COMMISSIONING TESTER FOR PV SYSTEM UP TO 1000V / 30A

• Continuity of protective circuit with 200mA
• Polarity
• Open circuit voltage Voc of PV modules and strings 1000V
• Short circuit current Isc on PV modules and strings 30A
• PV string/field insulation with test voltage 250, 500, 1000VDC
• Measurement of polarization index P.I.
• Dielectric absorption ratio D.A.R
• GFL function to locate the fault position in the string
• Measurement category CAT III 1000V
• OPT function for insulation testing on PV strings in the presence of MLPE

 

SAFETY TESTER FOR PHOTOVOLTAIC SYSTEMS HT PVCHECK

• Safety test of PV installation
• Continuity test on protective conductors with 200mA
• Insulation test with test voltage of 250, 500, 1000VDC
• DC voltage
• DC current
• DC Power
• Solar irradiation [W/m2] with reference cell

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

DIGITAL MULTIFUNCTION VDE MULTIMETER HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution

 

MULTIFUNCTION PORTABLE MULTIMETER FOR EARTH RESISTANCE MEASUREMENT HT ITALIA M73

• Trip out time measure on AC Standard RCD's
• Trip out current: 30, 30x5, 100, 300mA
• Global Earth Resistance with 0.1Ohm resolution
• Global Earth Resistance without RCD's tripping
• DC Voltage
• AC TRMS Voltage
• Automatic detection of AC/DC signals