THT80 Compact Infrared thermography camera 120x90pxl

Code: THT80


 

HT Infrared Cameras PDF, 7.48 Mb

Description

THT80
Compact infrared camera with 120x90pxl resolution

THT80 is the new compact professional thermal camera equipped with a high resolution 120x90pxl IR sensor, a measuring range of -20°C ÷ 550°C and a field of view of 50° x 37° which makes it suitable for use in frequent hydraulic, mechanical or electrical maintenance.
It is also equipped with the AutoFusion function and a large color display with high brightness capacitive touch-screen, for immediate use, as well as being usable through the new and convenient HT Pro Camera application.

Functions
IR Resolution120 x 90 pxl
Temperature range-20° ÷ 550°C
Image frequency50Hz
Thermal sensitivity / NETD<0.05°C @ 30°C / 50mK
Field of view (FOV)50° x 37°
Focal lengthf 1.13
Lens2.3mm
IFOV7.3mrad
Focus modefixed focus
Built-in camera2 MP, foco fijo, con linterna LED
Picture in Picture function
AutoFusion image enhancement
Uncertainty about the measure±2°C (±3.6°F) o±2% of reading
Digital zoom1x ÷ 32x
Measurement tools (in live mode)3 spots, central spot, hot / cold spot, 3 areas, horizontal vertical lines
Area measurement informationmax, min, center
IR Video recording
Measurement correctionsemissivity, reflected temperature, ambient temperature, atmospheric humidity, infrared compensation, distance compensation
Color Palettesiron, rainbow, white hot, black hot, brown hot, blue/red, hot/cold, feather, above max alarm, below min alarm, interval alarm
Span modesAutomatic / Manual / Histogram
Built in LED light
Internal memory3,4 GB
On-camera report buildingtextual notes
Communication modesUSB tipo C, Wi-fi, micro SD
Displaytouch screen
Battery operation time3 hours
Size (LxWxH) (mm)133 x 87 x 24mm

 

More products HT ITALIA

DIGITAL MULTIFUNCTION VDE MULTIMETER HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution

 

DIGITAL PROCESS CALIBRATOR PORTABLE MULTIMETER HT ITALIA HT8000

• Generation of output voltage signal with amplitude up to 10VDC
• Voltage measurement up to 10VDC
• Generation of output current signal with amplitude up to 24mADC
• Current measurement up to 24mAVDC
• Current measurement in percentage format (4-20mA)
• Loop current measurement of external transducers

 

HANDHELD DIGITAL MEGOHMMETER INSULATION & CONTINUITY 4 GOHM 1000V HT ITALIA M70

• Insulation with test voltage 250, 500, 1000VDC
• Up to 4Gohm measurement range
• Automatic discharge of device under test
• LOCK feature for continuous measurements
• Programmable timer up to 60s
• Continuity of earth conductors with test current of 200mA
• A/DC voltage up to 600V
• Resistance and continuity test with buzzer

 

HT SOLAR I-VE MULTIFUNCTION I-V CURVE TRACER FOR PHOTOVOLTAIC SYSTEMS

• 1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
• Measurement of efficiency of a single-phase photovoltaic system
• Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
• Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
• Measurement of short-circuit current of a module or of a string (ISC) 15A

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

STEP AND CONTACT VOLTAGE METER WITH TEST CURRENT UP TO 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC

 

PV-ISOTEST TESTER FOR CHECKING ELECTRIC SAFETY OF PHOTOVOLTAIC PANELS WITH GROUD FAULT LOCATION GFL FUNCTION

• Insulation measurement up to 1,500V DC even on live systems
• Localization of the faulty module through the new GFL function
• Continuity of the protective conductor with 200mA

 

PROFESSIONAL MULTIMETER CABLE VERIFIER FOR LAN VDE CHECKING HT ITALIA M75

• DC Voltage
• AC TRMS Voltage
• Continuity test of protective conductors with 200mA
• Insulation Resistance measurement with 500VDC
• Global Earth Resistance without RCD tripping
• Test executed on twisted pairs cables UTP and STP with RJ45 connector
• Quickly selection of cables pairs

 

HANDHELD DIGITAL EARTH RESISTANCE METER HT ITALIA GEO416

• 3-wire Earth Resistance
• 2-wire Earth Resistance
• 4-wire Earth Resistivity
• High measurement range (50kOhm)
• Noise voltage measure
• Optical /USB PC interface

 

POWER ANALYZER CURRENT CLAMP METER HT ITALIA HT9022

• DC, AC + DC TRMS current up to 1000A
• DC, AC + DC TRMS voltage up to 1000V
• Resistance and continuity test
• Active, Reactive, Apparent power on Single/Three phase systems
• Active, Reactive energy on Single/Three phase systems
• Power Factor on Single/Three phase systems
• Harmonic voltage/current up to 25th with THD% calculation
• PC connection via Bluetooth