YOKOGAWA Clamp-on Tester CL135 (True RMS, ACA, ACV, 600A)

Cod: YOKOGAWA CL135


 

Brosura produs PDF, 1.05 Mb

Descriere

Features:

  • AC current measurement with current ranges up to 600A
  • AC voltage and resistance measurements
  • 30mm in diameter of measurable conductor
  • True RMS Display
  • Data hold function
  • Approved for comformity to safety standard EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. Ill 600 V)

 

Display (LCD, Digital Counts)

1999

AC Current Accuracy (200A Reference)

1.5+4(50/60Hz)
2.0+5(40~1kHz)

AC Current Accuracy (600A Reference)

1.5+4(50/60Hz)
2.0+5(40~1kHz)

AC Voltage Accuracy (200V/600V Reference)

1.0+2(50/60Hz)
1.5+4(40~1kHz)

Crest Factor

(50/60Hz)

Resistance Accuracy (200O reference)

1.2+4, Beeps at below 30O (continuity check)

Method of detection

True RMS

Response Time

Approx. 1 seconds (approx. 2 seconds on resistance range)

Range Switching

Manual-range

Data hold

On all range

Operating temperature and humidity

-10-50°C. (no condensation)
up to 30°C, 90% RH
up to 40°C, 75% RH
up to 50°C, 45% RH

Influence of external magnetic field

2A or less at 400A/m

Influence of conductor position

± 3% or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

600Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

6F22(006P)9Vx1 or 6LR61x2

Battery Life1

100 hours

Consumed current

Approx. 2mA

Auto power-off

Approx. 10 minutes

Diameter of measurable conductor

30mm at maximum

Dimensions

Approx. 93(W)x210(H)x40(D)mm

Weight (Approx.)

400g

Accessories

Clamp Adapter (Model 99025), Carrying Case (Model 93032), Test Lead (Model 98010), User's manual (IM CL120), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

 

 

Alte produse YOKOGAWA

YOKOGAWA DM7560 DIGITAL MULTIMETER 6.5 DIGIT

• Full-color,high-resolution display with flexible display formats
• High-speed data logging with up to 30 k points per second
• High-capacity internal memory up to 100 k points
• Trend / histogram analysis available both in real-time and offline

 

YOKOGAWA LOW PRESSURE CALIBRATOR CA700

• IP54 dustproof and water proof case for harsh environments
• 4-20mA step function for signal generation
• 20mA Simulator to carry out loop test.
• Two-wire Transmitter Loop Check

 

YOKOGAWA CLAMP-ON TESTER CL150 (ACA, ACV, DCV, OHM, 2000A)

• AC/DC voltage and resistance measurements
• 54mm in diameter of measurable conductor
• Mean value display
• DC output function
• Data hold function

 

YOKOGAWA GS200 DC VOLTAGE / CURRENT SOURCE

• Voltage source up to ±32 V and current source up to ±200 mA
• 51/2-digit, 120000-count output resolution
• Voltage and current simple monitoring feature (optional)
• Programmable output up to 10,000 points
• Built-in USB mass storage device
• Channel expansion through synchronous operation

 

YOKOGAWA CLAMP-ON PROCESS METER CL420 (DC MA CURRENT)

• 0.2% Accuracy, 0.01mA Resolution
• Dual Display
• LED Torch Light, Backlight Display
• Analog Output Available

 

YOKOGAWA AQ7280 OTDR REFLECTOMETRU MODULAR TESTARE FIBRA OPTICA

• Reliability: Robust design for operating under harsh field conditions. Proven operating system assuring stability, prompt response, and superior protection against software virus attacks.
• Ease-Of-Use: Dual operation mode by multi-touch touchscreen and hard-key buttons. Fully automatic measurement and easy-to-read analysis reports through new software applications.
• Speed: Lightning startup time. Multi-tasking operation to enhance productivity. Immediate reporting via wireless connectivity.

 

YOKOGAWA - DL850E DL850EV SCOPECORDER

• Voltage & Currents
• Sensor Outputs
• Temperature, Vibration/Acceleration, Strain, Frequency
• Logic Signals & CAN / LIN and SENT

 

YOKOGAWA CLAMP-ON TESTER CL130 (ACA, ACV, 600A)

• AC current measurement with current ranges up to 600A
• AC voltage and resistance measurements
• 30mm in diameter of measurable conductor
• Mean value display
• Data hold function

 

YOKOGAWA -Q1300 SERIES 1G/10G ETHERNET MULTI FIELD TESTER

• Optical and electrical measurement ports for 10M to 1G (AQ1301) and 10M to 10G (AQ1300) are available
• Built-in Optical power meter (factory-installed option for the AQ1300)
• Equipped with a variety of test functions to evaluate Ethernet performance, such as a throughput test, latency measurement, bit error rate test, and PING test.

 

YOKOGAWA CALIBRATOR DE PROCES CA300 CA310 CA320 CA330

• Basic Accuracy: 0.015% (Source&Meas. accuracy of Voltage mA)
• Simultaneously supplies 24V loop power and measure output signal with high accuracy
• Sub display displays span% of the source value
• HART/BRAIN comm. resistance (250O) embedded