YOKOGAWA Clamp-on Tester CL130 (ACA, ACV, 600A)

Cod: YOKOGAWA CL130


 

Brosura produs PDF, 1.05 Mb

Descriere

Display (LCD, Digital Counts)

1999

AC Current Accuracy (200A Reference)

1.5+6(50/60Hz)
2.0+5(40~1kHz)

AC Current Accuracy (600A Reference)

1.0+3(50/60Hz)
2.0+5(40~1kHz)

AC Voltage Accuracy (200V/600V Reference)

1.0+2(50/60Hz)
1.5+4(40~1kHz)

Resistance Accuracy (200O reference)

1.2+4, Beeps at below 30O (continuity check)

Method of detection

Mean Value

Response Time

Approx. 1 seconds (approx. 2 seconds on resistance range)

Range Switching

Manual-range

Data hold

On all range

Operating temperature and humidity

-10-50°C. (no condensation)
up to 30°C, 90% RH
up to 40°C, 75% RH
up to 50°C, 45% RH

Influence of external magnetic field

2A or less at 400A/m

Influence of conductor position

± 2% or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

600Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

6F22(006P)9Vx1 or 6LR61x2

Battery Life1

200 hours

Consumed current

Approx. 2mA

Auto power-off

Approx. 10 minutes

Diameter of measurable conductor

30mm at maximum

Dimensions

Approx. 93(W)x210(H)x40(D)mm

Weight (Approx.)

400g

Accessories

Clamp Adapter (Model 99025), Carrying Case (Model 93032), Test Lead (Model 98010), User's manual (IM CL130), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

Alte produse YOKOGAWA

YOKOGAWA DIGITAL MULTIMETER TY720

• True RMS measurement
• New Functions for Electronic and Industrial Use
• Simultaneous measurement and display of DC and AC
• Switchable RMS/MEAN detection

 

YOKOGAWA 2560A HIGH VOLTAGE AND HIGH CURRENT PRECISION DC CALIBRATOR

• Wide output range of voltage and current generation
• Dials and switches for each digit and function
• High accuracy, stability, and resolution
• Various effective functions for analog meters calibration.

 

YOKOGAWA - DLM4000 OSCILOSCOP DIGITAL SEMNALE MIXTE

• DLM4038 350MHz
• DLM4058 500MHz
• (Standard) 8 analog channels or 7 analog channels + 8 bit logic
• (/L16 option) 8 analog channels + 16 bit logic or 7 analog channels + 24 bit logic
• Motor control & inverter circuit development
• Reliable triggering
• Best in Class Deep Memory & Architecture
• Two fully independent zoom windows

 

YOKOGAWA - WT3000E ANALIZOR DE PUTERE DE PRECIZIE

• Basic power accuracy: 0.01% of reading
• Both 2 A and 30 A input elements can be installed in a single unit
• Good readability: 8.4-inch LCD and the range indicator LEDs
• Simultaneous measurement with 2 units (Up to 8 power input elements)
• Store function: 50 ms data storing interval

 

YOKOGAWA DIGITAL INSULATION TESTER MY40

• 3 1/2-digit LCD;
• For each rating, you can save as many as 20 measurements at desired memory address numbers.
• Four AA (R6P) batteries the tester retains the measured resistance for approximately 5 seconds after the MEAS switch is turned off.

 

YOKOGAWA CLAMP-ON TESTER CL130 (ACA, ACV, 600A)

• AC current measurement with current ranges up to 600A
• AC voltage and resistance measurements
• 30mm in diameter of measurable conductor
• Mean value display
• Data hold function

 

YOKOGAWA AQ1200 OTDR FIBRA OPTICA COMPACT PORTABIL

• Applicable for installation and maintenance
• Models with a wavelength dedicated for maintenance of live fibers.
• These tri-wavelength models has two ports.

 

YOKOGAWA LOW PRESSURE CALIBRATOR CA700

• IP54 dustproof and water proof case for harsh environments
• 4-20mA step function for signal generation
• 20mA Simulator to carry out loop test.
• Two-wire Transmitter Loop Check

 

YOKOGAWA AQ2180 POWERMETRU OPTICA PORTABIL

• Two versions of Power Meters to suit test application
• Versatile data storage and transfer
• Auto switching of measurement wavelength
• Power source

 

YOKOGAWA GS820 MULTI CHANNEL SOURCE MEASURE UNIT

• DC voltage/current reference, pulse voltage/current source
• V-I curve trace, semiconductor parametric test
• Programmable arbitrary waveform generation
• Electric load, resistance measurement
• Production test