Brand: MTS

Amplificatoare putere semnal RF 1..3000 MHz MTS Seria MLV/MKV

Cod: MTS MLV/ MKV Series


 

Brosura produs PDF, 2.55 Mb

Descriere

  • Frequency Ranges: 1..100 MHz ~ 300..3000 MHz
  • Gain: 8.5..40 dB
  • Output power P at -1 dB min. : 11..30 dBm
  • Noise figure max.: 3.5..7 dB

Power Amplifiers (50 ?), series MLV

 

Model

Frequency range

Gain min.

Output power P at -1 dB min.

Noise figure
max.

MLV-557-0942-02

1 MHz - 500 MHz

40 dB

37 dBm

7 dB

MLV-557-0942-03

1 MHz - 500 MHz

40 dB

37 dBm

7 dB

MLV-647-0976-03

1 MHz - 1000 MHz

35 dB

37 dBm

7 dB

 

 

Small Signal Amplifiers (50 ?), series MKV

 

Model

Frequency range

Gain min.

Output power P at -1 dB min.

Noise figure
max.

MKV-426-5441

8 MHz - 300 MHz

8,5 dB

30 dBm

5 dB

MKV-436-5441

8 MHz - 300 MHz

20 dB

30 dBm

5,5 dB

MKV-446-5441

8 MHz - 300 MHz

31 dB

30 dBm

5,5 dB

MKV-626-5441

50 MHz - 1000 MHz

8,5 dB

29 dBm

5 dB

MKV-636-5441

50 MHz - 1000 MHz

20 dB

28,5 dBm

6 dB

MKV-646-5441

50 MHz - 1000 MHz

31 dB

28,5 dBm

6 dB

MKV-635-0969-03

100 MHz - 1000 MHz

23 dB

17 dBm

3,5 dB

MKV-635-0971

1 MHz - 1000 MHz

20 dB

17 dBm

4,5 dB

MKV-745-0973

100 MHz - 2000 MHz

31 dB

11 dBm

5 dB

MKV-822-0200

30 MHz - 3000 MHz

16 dB

-15 dBm

2,5 dB

MKV-835-0972

50 MHz - 2200 MHz

23 dB

12 dBm

7 dB

 

Optiuni recomandate

  • RF-cables
  • Bias tees
  • Heat sinks
 

Alte produse MTS

CAMERA ANECOICA ECRANATA 700..4200 MHZ MTS MSB-0023

• Highest quality materials for extended life time and high test appearance
• Economical solution for very high RF shielding levels and reproducible test scenarios to avoid time-consuming and expensive tests at EMC laboratories.
• Usable for frequencies between 700 MHz and 4200 MHz, such as GSM / DCS / DECT / UMTS / RFID / ZigBee / Bluetooth /WLAN etc.
• Weight optimized structure
• Inside coated with RF absorber material

 

ANTENA EMC HIBRIDA DE BANDA LARGA 60..6000 MHZ MTS MTA-60-6000

• Frequency Range: 60MHz - 6000 MHz (effective use 20 MHz - 6000 MHz)
• Type: EMC Wideband Antenna, hybrid
• Gain: 8 dBi typ.
• Power: 500 W CW (1000 W peak)

 

ANTENA PARABOLICA COMUNICATII RADIO MILITARE PUNCT LA PUNCT BANDA 3 SI 3+ 1350..2700 MHZ MTS ANT-BAND3+

• Frequency Range: 1350 MHz - 2700 MHz
• Type: Band 3+ Antenna, parabolic dish
• Gain: 19 dBi typ.
• Power: 500 W CW (1000 W peak)

 

ANTENA DE MASURA RADITII MAGNETICE FRECVENTE JOASE 9 KHZ..30 MZ MTS MTA-MLA-930A

• Frequency Range: 9 kHz - 30 MHz
• Type: Active Magnetical Loop, hand-guided

 

PREAMPLIFICATOR ANTENA BANDA LARGA 30..3000 MHZ MTS MKV-822-0200

• Frequency Range: 30 MHz - 3000 MHz
• Gain: 16 dB
• Output power P at -1 dB min. -15 dBm

 

ATENUATOARE PROGRAMABILE SEMNALE COMUNICATII MTS

• Frequency ranges: 200..800 ~ 2900..4000 MHz
• Max. attenuation: 65..93 dB
• Input power max.: +26 dB
• Control: RS-232, IEEE488, LAN and manual control

 

INCINTA DE ECRANARE RADIATII ELECTROMAGNETICE 700..4200 MHZ MTS MSB-0035-VGA-LAN

• Highest quality materials for extended life time and high test appearance
• Economical solution for high RF shielding levels
• Usable for frequencies between 700 MHz to 4200 MHz, such as GSM / DCS / DECT / UMTS / RFID / ZigBee / Bluetooth /
• WLAN etc.
• Easy operation of the test samples directly through the built-in flexible wire mesh
• Weight optimized structure improves the mobility

 

SIMULATOR ANTENA / EMULATOR INTERFATA AER/ ADAPTOR TESTARE COMUNICATII

• Time and cost saving through fast failure search with real RF signals instead of simulations
• Less error rate in test cases compared with software simulations
• Independency from RF-radiation of the environment
• Repeatable results
• Ideal working due to customized configuration
• Easy operation by manual control or by graphic user interface

 

ANTENA EMC HIBRIDA DE BANDA LARGA 60..2000 MHZ MTS MTA-60-2000

• Frequency Range: 60MHz - 2000 MHz (effective use 20 MHz - 2000 MHz)
• Type: EMC Wideband Antenna, hybrid
• Gain: 8 dBi typ.
• Power: 500 W CW (1000 W peak)

 

COMUTATOARE RELEE SEMNALE RADIO COMUNICATII MTS

• Various switch applications from DC to 40 GHz with electromechanical or solid state relays
• Switching unit for RF-generators, amplifiers and antennas at EMC test laboratories
• RF matrix
• Filter, diplexer, attenuator etc. selection unit
• Any automated routing of measurement equipment at test benches