Calibrator putere si energie activa, reactiva, aparenta, faza, unghi Meatest M133i

Cod: Meatest M133i


 

Brosura produs PDF, 0.5 Mb

Descriere

  • Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
  • AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
  • DC/AC current 30 mA to 30 A / 5 V, accuracy 310 ppm
  • Power factor setting -1 to +1
  • Frequency range 15 Hz to 1 kHz
  • Simulated electric power up to 8.4 kVA (420 kVA with option 140-50)
  • Built-in process multimeter
  • GPIB & RS232 interface
 

Accesorii standard

  • Power supply cable  1 pc
  • Operation manual, CD  1 pc
  • Option 10/11  Test lead 1000V - 30 A, black/red 4 pc Length 1m
  • Spare fuse  1 pc
  • RS 232 cable  1 pc Length 1.5m
 

Optiuni recomandate

  • Option 140-50 Current coil 25/50 turns For clamp ammeters
  • Option 10 Test lead 1000V/32A (black) Length 1m
  • Option 11 Test lead 1000V/32A (red) Length 1m
  • GPIB cable GPIB interface cable Length 1 m
  • RS-232 cable RS-232 interface cable Length 1.5 m
  • POWER Application SW. Transducers calibration.
 

Alte produse MEATEST

CALIBRATOR PUTERE SI ENERGIE ACTIVA, REACTIVA, APARENTA, FAZA, UNGHI MEATEST M133I

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 30 mA to 30 A / 5 V, accuracy 310 ppm
• Power factor setting -1 to +1
• Frequency range 15 Hz to 1 kHz
• Simulated electric power up to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

REZISTOR ETALON DE PRECIZIE SI FRECVENTA INALTA CALIBRARE RLC-METRE MEATEST M530

• Resistance range 10 O to 1000 O
• Very low frequency dependency
• Applicable frequency range to 100 MHz
• Calibration of wide frequency range LCR meters

 

CALIBRATOR MULTIFUNCTIONAL DE INALTA PRECIZIE MEATEST M142

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• Resistance up to 1000 MO, capacitance up to 100 uF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 20 A
• Built-in process multimeter
• GPIB & RS232 interface

 

CALIBRATOR DE LABORATOR TENSIUNE, CURENT, REZISTENTA, CAPACITATE, FRECVENTA MEATEST M140

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• Resistance up to 50 MO, capacitance up to 50 µF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 10 A
• Built-in process multimeter
• GPIB & RS232 interface

 

CALIBRATOR DE PUTERE SI ENERGIE ELECTRICA MEATEST M133

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• Power factor setting -1 to +1
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

DECADA REZISTIVA CALIBRARE MEGOHMMETRE SI TESTERE IZOLATIE 5KV MEATEST M109R

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

CALIBRATOR UNIVERSAL MULTIFUNCTIONAL DE LABORATOR SI PRECIZIE MEATEST M143

• Wide voltage range from 0 to 1000 V DC/AC with accuracy 0.01 %
• Extended current range from 0 to 20 A DC/AC with accuracy 0.02 %
• Extended current range to 1000 A for calibration of clamp ammeters
• Sinusoidal & Non-sinusoidal waveforms
• Fix standard resistors 10 O to 100 MO in decimal values with calibration accuracy 0.02 %
• Thermocouple temperature sensor simulation R, S, B, J, T, E, K, N in range from 250 °C to 1850 °C
• Cold junction automatic compensation using external Pt1000 sensor
• RTD temperature sensor simulator as option

 

CALIBRATOR PUTERE SI ENERGIE ELECTRICA TRIFAZICA MEATEST M133CI

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• DC/AC current 90 A in one phase configuration
• Power factor setting -1 to +1
• Floating current outputs to 450 Vpk
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 54 kVA (2.7 MVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

DECADA CAPACITIVA CALIBRARE RLC-METRE MEATEST M520

• Designed for RCL meters calibration
• Range of capacitance from 100 pF to 12 mF
• Basic accuracy 0.25 %
• Maximal operating voltage 50 V
• Power supplying from internal battery or power line adapter
• Remote control RS-232

 

DECADA REZISTENTE MARI CALIBRARE MEGOHMMETRE SI TESTERE IZOLATIE INALTA TENSIUNE 10KV MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification