Lanterna cu lumina UV ultravioleta pentru detectie scurgeri freon Fluke RLD2

Cod: Fluke RDL2


 

Descriere

UV Refrigerant leak Detector Flashlight

 

Leak detection made easy

 

The compact, easy-to-use, RLD2 UV flashlight uncovers refrigerant leaks instantly. Use the UV light to find the leakage area, then, use the laser pointer to pinpoint the exact leak location. With 100,000 hours of life, and four operating modes, this versatile leak detector is a must have for HVAC Technicians.         

 

  • Six UV LEDs (395 nm wavelength) detect leak detection dyes
  • Laser pointer clearly locates center of the UV field for accuracy
  • Three LED flashlight with 100,000 hour LED life
  • Operating temperature 0 ° C to 50 ° C
  • Four operating modes: flashlight, UV light, laser light, UV/laser light combination
  • Convenient detachable key chain carabiner and AAA battery included
 

Alte produse FLUKE

TESTER MULTIFUNCTIONAL TEMPERATURA, UMIDITATE, VITEZA AER, CO, CO2 FLUKE 975

• Temperature -20 °C to 50 °C (-5 °F to 122 °F)
• Velocity 0.25 m/sec to 15 m/sec
• Relative Humidity 10 % to 90 % RH, non-condensing
• CO2 0 to 5000 ppm
• CO 0 to 500 ppm

 

MODUL WIRELESS DE ACHIZITIE TEMPERATURA CU SENZOR TIP K FLUKE CNX T3000

• Masuratori de temperatura de la -200 °C pâna la 1.372 °C
• Precizie de ± 0,5%
• Înregistrare în memorie a pâna la 65.000 de masuratori
• Afisaj LCD cu lumina de fundal
• IP30


MULTIMETRU DIGITAL PORTABIL HVAC 3.5 DIGIT FLUKE 116

• 3.5 digit
• 6000 count
• 0.5% accuracy
• Built-in thermometer for HVAC applications
• Microamps to test flame sensors

 

POMPA HIDRAULICA CALIBRARE PRESIUNI FLUKE 700HTP-2

• hand operated hydraulic pressure pump
• designed to generate calibration pressures up to 10,000 psi/690 bar
• Variable size stroke adjustment, allows the user to vary the volume and pressure per stroke
• Integral pressure adjustment vernier knob for fine pressure adjustment
• Directly connection to pressure modules consolidates two separate pieces into one when performing pressure calibration and testing
• Two ¼ inch NPT pressure ports, one for reference (pressure module or gauge), one for UUT
• Improved priming
• Improved stroke limiting mechanism

 

CALIBRATOR DE PRESIUNE FLUKE 718EX

• ATEX II 1G Ex ia IIC T4 Compliant
• Built-in pressure / vacuum hand pump
• Pressure measurement to 0.05%
• Pressure measurement to 200

 

SISTEM INDUSTRIAL MONITORIZARE FLUKE CNX 3000 HVAC

• masuratori de tensiune c.a. si c.c. true-rms, la 1.000 V
• curent c.a. si c.c. true-RMS, cu o rezolutie de 0,01 mA
• masuratori de temperatura de la -200 °C pâna la 1372 °C
• masuratori de curent c.a. true-RMA la 400 A


CLESTE CURENT CALIBRARE PROCES FLUKE 773

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity
• 0 to 30 V DC Voltage measure
• 0 to 10 V DC Voltage source

 

FLUKE TIS55 CAMERA DE TERMOVIZIUNE 220X165

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE 190-102 190-102/S OSCILOSCOP PORTABIL DIGITAL 2X100 MHZ

• 2-canale izolate 100MHz
• Clasa de protectie CAT III 1000 V, CAT IV 600 V
• Multimetru digital dedicat cu 5000 de numărări la modele cu două canale
• Măsurători automate avansate, energie (Vpwm, VA, W, PF) ™ timp (mAs, V/s, w/s)
• Clasa de protectie IP-51 pentru praf şi lichide pentru a rezista in medii dificile
• Porturi USB izolate

 

FLUKE 279 FC TRMS MULTIMETRU DIGITAL CU TERMOVIZIUNE

• Multimetru cu functii complete si camera de termoviziune integrata
• 15 functii de masurare, inclusiv: tensiune c.a. cu filtru trece-jos, tensiune c.c., rezistenta, continuitate, capacitate electrica, test dioda, min./max./med., intensitate c.a. (cu iFlex), frecventa
• Rezolutia imaginilor-80 x 60
• Ecran LCD color de 3,5 in/8,89 cm
• Categoria de masurare CAT III 1000 V, CAT IV 600 V