  • 0 to 300 V DC/AC Voltage measure
  • 0 to 15 V DC Voltage source / simulate
  • 0 to 110 mA DC Current measure
  • 0 to 22 mA DC Current  source / simulate
  • 0 to 11 kO Resistance measure / source / simulate
  • 1 to 50 kHz Frequency measure / source / simulate
  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Measure and source simultaneously with one compact, rugged, reliable tool
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white display. Read both sourced and measured parameters
  • Multi lingual interface
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1msec.
 

Accesorii standard

  • BC7217 battery charger
  • BP7217 battery pack
  • Instruction manual
  • NIST-traceable calibration report and data
  • One set of TP220 test probes
  • Two sets of AC220 test clips
  • Two sets of TL224 industrial test leads
 

Alte produse FLUKE

CLESTE AMPERMETRIC DE CURENT HVAC 600A FLUKE 902

• Designed for HVAC applications
• capacitance, DC Current (µA), and temperature measurements
• Small body and jaws

 

CALIBRATOR DE PRESIUNE FLUKE 721

• 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor
• 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
• Ideal for gas flow calibration (custody transfer) applications
• Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
• Pt100 RTD input for temperature measurement, (probe optional)
• Measures 4 to 20 mA signals
• Internal 24 V loop power supply can power a transmitter under test
• Measure up to 30 V dc, check 24 V loop power supplies

 

TESTER VIBRATII FLUKE 805

• measures overall vibration as well as specific variables like bearing condition and temperature
• calculate bearing condition and overall vibration
• Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz)
• Exportable data via USB
• Crest Factor+

 

CLESTE AMPERMETRIC DE CURENT TRUE-RMS AC/DC 200A FLUKE 365

• 200 A AC and DC current measurement with detachable jaw
• 600 V AC and DC voltage measurement
• True-rms AC voltage and current
• 6000 O resistance measurement

 

CLESTE CURENT CALIBRARE PROCES FLUKE 771

• 0 to 21 mA, 10 to 50 mA Current measure
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity

 

TERMOMETRU INFRAROSU CU TERMOCUPLU DE CONTACT FLUKE 566/ FLUKE 568

• Measure -40 °C to 800 °C /-40 °F to 1472 °F (568) or -40 °C to 650 °C/-40 °F to 1202 °F (566)
• Easily access advanced features with the soft-key buttons and dot-matrix display
• Measure smaller objects from further away, with a distance-to-spot ratio of 50:1 (568) or 30:1 (566)
• Compatibility with all standard miniconnector Type-K thermocouples allow you to preserve your thermocouple investments

 

FLUKE 125B 125B/S SCOPEMETER OSCILOSCOP PORTABIL 2X40MHZ

• 2-canale 40MHz
• Osciloscop digital cu intrare dublă şi multimetru
• Lătime de bandă a osciloscopului de 40 MHz sau 20 MHz
• Două multimetre digitale true-RMS cu limită de numărare de impulsuri 5000
• Măsurarea energiei (W, VA, VAR, PF, DPF, Hz)
• Tensiune, curent şi armonice de energie
• Adaptor WiFi optional conectat la port USB intern pentru transfer wireless de informatii către PC, laptop sau aplicatia mobilă Fluke Connect®*1

 

TELEMETRU LASER PORTABIL 80M FLUKE 419D

• Instantly measures up to 80m (260 ft) with accuracy of +/- 1mm
• 3-line display plus storage for 20 complete displays
• Tripod mountable

 

CLESTE MASURARE PRIZA DE PAMANT FLUKE 1630

• resistance range from 0.025 O to 1500 O
• large jaw opening of 35 mm
• ground leakage current, from 0.2 mA to 1000 mA
• ac current measurement range from 0.2 A to 30 A

 

CLESTE CURENT CALIBRARE PROCES FLUKE 773

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity
• 0 to 30 V DC Voltage measure
• 0 to 10 V DC Voltage source