YOKOGAWA Clamp-On Tester CL220 (AC/DC 300A)

Code: YOKOGAWA CL220


 

Datasheet PDF, 1.05 Mb

Description

Features:

  • AC/DC current measurements with current ranges up to 300A
  • 24mm in diameter of measurable conductor
  • Light weight & compact design
  • Mean value display
  • Sleep function
  • Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)

 

Description

AC/DC Mini Clamp-on

Method of detection

Mean Value

Display

LCD (Digital display: 3999 counts)

DC Current Range

40/300A

DC Current Resolution

0.01A

Response Time

Approx. 2 second

Range Switching

Auto-range

Data hold

On all range

Operating temperature and humidity

0 - 40°C, 90% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400 A/m

Influence of conductor position

±(2% rdg + 5dgt) or less

Safety Standard

Conforms EN61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

300 Vrms or less

Withstanding voltage

3.7 kV AC for one minute

Power Supply

LR-44 x 2 (3V)
SR-44 x 2

Battery Life

Approx. 11 hours (continuous)

Consumed current

Approx. 9 mA

Sleep Function

Automatically powered down in about 5 minutes after the last switch operation

Diameter of measurable conductor

24 mm at maximum

Dimensions

Approx. 59 (W) x 147 (H) x 25 (D) mm

Weight

Approx. 100 g

Accessories

Batteries, carrying case (93033)
User's manual (IM CL235)

 

 

More products YOKOGAWA

YOKOGAWA DIGITAL MULTIMETER TY710

• Conforms to safety standards EN61010-1 1000V CAT., 600V CAT.
• Safety shutters for preventing erroneous insertion of test leads into current measurement terminals
• Operating temperature range -20 to +55C
• Storage temperature range -40 to +70
• Closed Case Calibration

 

YOKOGAWA CLAMP-ON POWER METER CW10 (SINGLE-PHASE)

• AC / DC Power up to 600 kW, AC / DC Voltage max. 1000 V, AC / DC Current max. 600 A
• True RMS for AC .
• Harmonics 1st to 25th order
• Power fluctuation using the ACA Inrush and Peak hold functions.
• Frequency, Resistance, Continuity, Diode check, Power factor.

 

YOKOGAWA - WT500 MID-RANGE POWER ANALYZER

• Current range: 0.5 to 40 A
• Voltage range: 15 to 1000 V
• Basic Power Accuracy: 0.1%
• frequency range: DC 0.5 Hz to 100 kHz

 

YOKOGAWA PROCESS MULTIMETER CA450

• Simultaneous 24 V loop power and mA measurement
• HART mode setting with loop power (250 OHM resistance)
• High accuracy signal measurement: DC mA 0.05%/30.000 mA
• Handheld DMM function
• Peak/Hold function for DCS power peak-to-peak measurement

 

YOKOGAWA AQ1200 COMPACT OPTICAL TIME DOMAIN REFLECTOMETER

• Applicable for installation and maintenance
• Models with a wavelength dedicated for maintenance of live fibers.
• These tri-wavelength models has two ports.

 

YOKOGAWA CLAMP-ON TESTER CL150 (ACA, ACV, DCV, OHM, 2000A)

• AC/DC voltage and resistance measurements
• 54mm in diameter of measurable conductor
• Mean value display
• DC output function
• Data hold function

 

YOKOGAWA MULTIFUNCTION CALIBRATOR CA150 (HANDHELD)

• Vertical Hand-Held Calibrator
• Simultaneous Source and Measurement for Process Devices
• Loop Power Supply Function
• Highly Accurate and Multi-Functional Source and Measurement

 

YOKOGAWA - DLM4000 MIXED SIGNAL OSCILLOSCOPES

• DLM4038 350MHz
• DLM4058 500MHz
• (Standard) 8 analog channels or 7 analog channels + 8 bit logic
• (/L16 option) 8 analog channels + 16 bit logic or 7 analog channels + 24 bit logic
• Motor control & inverter circuit development
• Reliable triggering
• Best in Class Deep Memory & Architecture
• Two fully independent zoom windows

 

YOKOGAWA - MINI CLAMP-ON TESTER CL120 (200A)

• Exclusive model for AC current measurement with current ranges up to 200A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display

 

YOKOGAWA AQ1100 OPTICAL LOSS TEST SET

• 5.7 inch color LCD for easy viewing
• Multi-Language support
• Multi-core fiber measurement with a pair set
• USB port for data storage