YOKOGAWA -lamp-on Tester CL155 (AC, True RMS, 2000A)

Code: YOKOGAWA CL155


 

Datasheet PDF, 1.05 Mb

Description

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • True RMS display
  • 54mm in diameter of measurable conductor
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. HI 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

2.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

?.5% rdg ± 0.5mV (50/60Hz)
?.5% rdg ± 0.5mV (40~1kHz)

Method of detection

True RMS

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2.0% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W)x247(H)x49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011) User's manual (IM CL120), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

More products YOKOGAWA

YOKOGAWA - DIGITAL LUX METERS 51000 SERIES

• Wide measurement range, high accuracy
• Spectral response characteristics for visible range
• Good oblique incident light characteristics
• USB communication and USB power supply
• Recorder output

 

YOKOGAWA DIGITAL INSULATION TESTER MY40

• 3 1/2-digit LCD;
• For each rating, you can save as many as 20 measurements at desired memory address numbers.
• Four AA (R6P) batteries the tester retains the measured resistance for approximately 5 seconds after the MEAS switch is turned off.

 

YOKOGAWA DIGITAL MULTIMETER TY530

• Basic accuracy 0.09%
• True RMS measurement
• Ensured Field Site Safety
• Conforms to safety standards EN61010-1, 1000V CAT III, 600V CAT IV

 

YOKOGAWA MULTIFUNCTION CALIBRATOR CA150 (HANDHELD)

• Vertical Hand-Held Calibrator
• Simultaneous Source and Measurement for Process Devices
• Loop Power Supply Function
• Highly Accurate and Multi-Functional Source and Measurement

 

YOKOGAWA DIGITAL MULTIMETER TY710

• Conforms to safety standards EN61010-1 1000V CAT., 600V CAT.
• Safety shutters for preventing erroneous insertion of test leads into current measurement terminals
• Operating temperature range -20 to +55C
• Storage temperature range -40 to +70
• Closed Case Calibration

 

YOKOGAWA AQ6370D TELECOM OPTICAL SPECTRUM ANALYZER 600 - 1700 NM

• High wavelength accuracy: ±0.01nm
• High wavelength resolution: 0.02nm
• Wide dynamic range: 78dB typ.
• Wide level range: +20 to -90dBm

 

YOKOGAWA FG400 ISOLATED ARBITRARY/FUNCTION GENERATOR

• Frequency range: Sine wave 0.01 µHz to 30 MHz
• Amplitude resolution: 16 bits
• Sampling rate: 120 MS/s
• Output: 0 to 20 Volts, peak-to-peak

 

YOKOGAWA - WT1800E HIGH PERFORMANCE POWER ANALYZER

• Harmonics analysis up to the 500th order of a 50/60 Hz fundamental frequency
• Up to 6 input channels at 2 MS/s (16 bits)

 

YOKOGAWA CLAMP-ON TESTER CL135 (TRUE RMS, ACA, ACV, 600A)

• AC current measurement with current ranges up to 600A
• AC voltage and resistance measurements
• 30mm in diameter of measurable conductor
• True RMS Display
• Data hold function

 

YOKOGAWA PROCESS MULTIMETER CA450

• Simultaneous 24 V loop power and mA measurement
• HART mode setting with loop power (250 OHM resistance)
• High accuracy signal measurement: DC mA 0.05%/30.000 mA
• Handheld DMM function
• Peak/Hold function for DCS power peak-to-peak measurement