YOKOGAWA -lamp-on Tester CL155 (AC, True RMS, 2000A)

Code: YOKOGAWA CL155


 

Datasheet PDF, 1.05 Mb

Description

Features:

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • True RMS display
  • 54mm in diameter of measurable conductor
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for conformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. HI 600 V, CAT. II1000 V)

 

Display (LCD, Digital Counts)

3999

AC Current Accuracy (400A Reference)

1.0+3(50/60Hz)
2.0+3(40~1kHz)

AC Current Accuracy (2000A Reference, 0~1500A)

2.0+3(50/60Hz)
3.0+3(40~1kHz)

AC Voltage Accuracy (40/400V/750V Reference)

1.0+2(50/60Hz)
1.5+3(40~1kHz)

DC Voltage Accuracy (40/400V/1000V Reference)

1.0+2

Resistance Accuracy (400/4k/40k/400kO reference)

1.5+2, Beeps at below 50± 35O (continuity check)

DC Output Accuracy (400A, 0~400mV Reference)

?.5% rdg ± 0.5mV (50/60Hz)
?.5% rdg ± 0.5mV (40~1kHz)

Method of detection

True RMS

Response Time

Approx. 2 seconds

Range Switching

Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range)

Data hold

On all range

Operating temperature and humidity

0-40°C, 85% RH or less (no condensation)

Influence of external magnetic field

1A or less at 400A/m

Influence of conductor position

± (2.0% rdg + 3dgt) or less

Safety Standard

Conforms EN 61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000Vrms or less

Withstanding voltage

5.55kV AC for one minute

Power Supply

R6P(SUM-3)x2 or LR6x2

Battery Life1

150 hours

Consumed current

Approx. 5mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

54mm at maximum

Dimensions

Approx. 105(W)x247(H)x49(D)mm

Weight (Approx.)

470g

Accessories

Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011) User's manual (IM CL120), batteries

Order Notes

Each item selected MUST be ordered as a separate line item.

Product Notes

All Clamp-on Meters include Test Leads (where applicable) and a carrying case.

 

More products YOKOGAWA

YOKOGAWA - DL850E DL850EV SCOPECORDER

• Voltage & Currents
• Sensor Outputs
• Temperature, Vibration/Acceleration, Strain, Frequency
• Logic Signals & CAN / LIN and SENT

 

YOKOGAWA FG400 ISOLATED ARBITRARY/FUNCTION GENERATOR

• Frequency range: Sine wave 0.01 µHz to 30 MHz
• Amplitude resolution: 16 bits
• Sampling rate: 120 MS/s
• Output: 0 to 20 Volts, peak-to-peak

 

YOKOGAWA CLAMP-ON TESTER CL130 (ACA, ACV, 600A)

• AC current measurement with current ranges up to 600A
• AC voltage and resistance measurements
• 30mm in diameter of measurable conductor
• Mean value display
• Data hold function

 

YOKOGAWA AQ1000 ENTRY LEVEL OPTICAL TIME DOMAIN REFLECTOMETER

• Wavelengths: 1310 / 1550 nm
• Dynamic ranges: 32 / 30 dB
• Size: 185 mm (W) × 116 mm (H) × 56 mm (D) ( 7.3" (W) × 4.6" (H) × 2.2" (D) )
• Weight: 660 g ( 1.46 Lbs )

 

YOKOGAWA AQ6373B VISIBLE WAVELENGTH OPTICAL SPECTRUM ANALYZER 350 - 1200 NM

• Max safe input power: +20 dBm
• Level sensitivity: -80 dBm
• Dynamic range: ?60dB
• Single-mode, Multimode, and Large-core fibers
• Built-in optical alignment source

 

YOKOGAWA CLAMP-ON TESTER CL220 (AC/DC 300A)

• AC/DC current measurements with current ranges up to 300A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display
• Sleep function

 

YOKOGAWA DIGITAL RESISTANCE METER 7556

• Wide operating rangeability (1 Ohm range to 100 M Ohm range)
• Full remote controlability via the standard RS232C serial, or optional GP-IB interfaces
• Software based calibration
• Printer output of measurement, and statistical analysis results

 

YOKOGAWA - WT3000E PRECISION POWER ANALYZER

• Basic power accuracy: 0.01% of reading
• Both 2 A and 30 A input elements can be installed in a single unit
• Good readability: 8.4-inch LCD and the range indicator LEDs
• Simultaneous measurement with 2 units (Up to 8 power input elements)
• Store function: 50 ms data storing interval

 

YOKOGAWA CLAMP-ON PROCESS METER CL420 (DC MA CURRENT)

• 0.2% Accuracy, 0.01mA Resolution
• Dual Display
• LED Torch Light, Backlight Display
• Analog Output Available

 

YOKOGAWA - MINI CLAMP-ON TESTER CL120 (200A)

• Exclusive model for AC current measurement with current ranges up to 200A
• 24mm in diameter of measurable conductor
• Light weight & compact design
• Mean value display