YOKOGAWA Clamp-on Power Meter CW10 (Single-Phase)

Code: YOKOGAWA CW10 (Single-Phase)


 

Datasheet PDF, 1.01 Mb

Description

The Clamp-on Power Meter CW10 (Single-Phase) is more like a tester type rather than a recorder, which can measure single phase AC and DC Power, Voltage, Currents, Power Factor, Frequency, Harmonics. It will also contribute to workers maintenance of not only consuming equipment but equipment for renewable energy such as solar and wind power generation.

 

Features:

  • AC / DC Power up to 600 kW, AC / DC Voltage max. 1000 V, AC / DC Current max. 600 A
  • True RMS for AC .
  • Harmonics 1st to 25th order
  • Power fluctuation using the ACA Inrush and Peak hold functions.
  • Frequency, Resistance, Continuity, Diode check, Power factor.
  • Up to 9999 counts, approx. 37mm max. diameter of measurable conductor (the jaw opens approx. 45mm max.)
  • CATIV 600V and CATIII 1000V compliant for safety.
  • Backlight on the display area turns on and a white LED automatically illuminates the front of jaw when clamping.
  • Non-contact Voltage Detection (Red LED lights up on detection).
  • Easy Operation with the Navigator key.
  • Low Pass Filter, Phase Detection, AC / DC Auto Sense.
 

More products YOKOGAWA

YOKOGAWA EARTH TESTER EY200 (DIGITAL)

• 2P Test leads (for simplified measurement) has a structure that both the safety alligator clip and the test probe are available
• Warns when earth resistance of auxiliary earth spikes exceeds the permissible limit
• Convenient carrying soft bag for accessories etc.
• 3-Pole Earth Resistance Measurement (Precise Measurement)

 

YOKOGAWA MULTIFUNCTION CALIBRATOR CA71 CA51

• Autostep function
• Changes the output value in step form based on the setting from the divided output (n/m) function. Changes can be sourced automatically every 10% or 25%.
• Online communication (CA71 only) RS-232C-compliant optically isolated interface
• Sweep function
• Linearly increases or decrease the output. The increasing/decreasing time can be set to either 16 or 32 seconds.
• Memory function
• Source values and measurements forming individual value sets can be saved to or read from the Handy Calibrator's internal memory (maximum 50 value sets).
• Temperature monitor function

 

YOKOGAWA AQ2212 FRAME CONTROLLER (9 SLOTS)

• Easy-to-view color display
• USB port for data storage
• Measurement module "hot-swapping" capability
• Remote monitoring and measurement through a LAN

 

YOKOGAWA CLAMP-ON TESTER CL130 (ACA, ACV, 600A)

• AC current measurement with current ranges up to 600A
• AC voltage and resistance measurements
• 30mm in diameter of measurable conductor
• Mean value display
• Data hold function

 

YOKOGAWA AQ6360 TELECOM PRODUCTION OPTICAL SPECTRUM ANALYZER 1200 - 1650 NM

• Wavelength range: 1200 to 1650 nm
• Wavelength resolution: 0.1 to 2 nm
• High wavelength accuracy: ±0.02 nm
• High dynamic range: 55 dB
• Wide measurement range: +20 to -80 dBm

 

YOKOGAWA LS3300 AC POWER CALIBRATOR

• High Accuracy
• Phase Accuracy
• High Stability
• Wide generation range
• Single to three phase power calibration

 

YOKOGAWA AQ1100 OPTICAL LOSS TEST SET

• 5.7 inch color LCD for easy viewing
• Multi-Language support
• Multi-core fiber measurement with a pair set
• USB port for data storage

 

YOKOGAWA - SL1000 HIGH-SPEED DATA ACQUISITION UNIT

• Fast Acquisition
• Fast Transfer and Storage
• Easy to use
• Can operate "Standalone"

 

YOKOGAWA - PX8000 PRECISION POWER SCOPE

• Provides simultaneous voltage and current multiplication to give real-time power sampling.
• Trend measurements between waveforms can be calculated by mathematical functions (up to four million points).
• Supports the capture of power parameters over specific periods of time through the definition of start and stop "cursors".
• An always-active History function automatically records up to 1,000 historical waveforms.

 

YOKOGAWA DIGITAL MULTIMETER TY710

• Conforms to safety standards EN61010-1 1000V CAT., 600V CAT.
• Safety shutters for preventing erroneous insertion of test leads into current measurement terminals
• Operating temperature range -20 to +55C
• Storage temperature range -40 to +70
• Closed Case Calibration