YOKOGAWA Low Pressure Calibrator CA700

Code: YOKOGAWA Low Pressure Calibrator CA700


 

Datasheet PDF, 7.78 Mb

Description

The Low Pressure Calibrator CA700 has a basic accuracy of 0.01% of reading on pressure measurement and 0.015% of reading on Current/Voltage source/measurement, which makes it the most accurate calibrator in the portable calibrator class. The CA700 also has the highest resolution and widest range of any hand held portable in its class with resolution of 0.001 kpa (200.00 kpa range) and a resolution of 0.0001 psi (29 psi range). The CA700 supports "As Found", "As Left" data and error rate (%). In addition the CA700 stores calibration procedures for pressure transmitters and pressure switched which allow strong support for field calibration and maintenance work. The CA700 is housed in a robust IP54 dust proof and water proof case for use in harsh environments. Available in three model ranges which includes low pressure, medium pressure or high pressure with selectable high-performance hand pumps for each range. A new high pressure module, the PM100, is now available, that effectively increases the pressure range of the CA700 (firmware versions 1.10 or later) to 2300 PSI, all the while maintaining the same basic accuracy of 001%.

 

The Low Pressure Calibrator CA700 is the most accurate calibrator in the portable calibrator class having a basic accuracy of 0.01% of reading on pressure measurement and 0.015% of reading on Current/Voltage source measurement. Supporting "As Found", "As Left"  and error rate, makes the CA700 a great tool for field calibration and maintenance work. Available in low pressure, medium pressure or high pressure ranges  with selectable high-performance hand pumps for each range.

 

Features:

  • Accuracy 0.01% rdg for Pressure / 0.015% rdg for Current/Voltage (source/measurement)
  • Highest resolution class 0.001kPa (200.000 kPa range) 0.0001 psi (29 psi range)
  • "As Found", "As Left"  and error rate (%)
  • IP54 dustproof and water proof case for harsh environments
  • 4-20mA step function for signal generation
  • 20mA Simulator to carry out loop test. 
  • Two-wire Transmitter Loop Check
  • 250-ohm resistor for HART and BRAIN communication

 

 

More products YOKOGAWA

YOKOGAWA AQ6370D TELECOM OPTICAL SPECTRUM ANALYZER 600 - 1700 NM

• High wavelength accuracy: ±0.01nm
• High wavelength resolution: 0.02nm
• Wide dynamic range: 78dB typ.
• Wide level range: +20 to -90dBm

 

YOKOGAWA MULTIFUNCTION CALIBRATOR CA150 (HANDHELD)

• Vertical Hand-Held Calibrator
• Simultaneous Source and Measurement for Process Devices
• Loop Power Supply Function
• Highly Accurate and Multi-Functional Source and Measurement

 

YOKOGAWA - MINI-MANOMETER MT10

• High reliability (with silicon resonant sensor)
• Compact
• Accuracy: ± (0.04% of rdg + 0.03% of F.S.) (130 kPa model)

 

YOKOGAWA FG400 ISOLATED ARBITRARY/FUNCTION GENERATOR

• Frequency range: Sine wave 0.01 µHz to 30 MHz
• Amplitude resolution: 16 bits
• Sampling rate: 120 MS/s
• Output: 0 to 20 Volts, peak-to-peak

 

YOKOGAWA DM7560 DIGITAL MULTIMETER 6.5 DIGIT

• Full-color,high-resolution display with flexible display formats
• High-speed data logging with up to 30 k points per second
• High-capacity internal memory up to 100 k points
• Trend / histogram analysis available both in real-time and offline

 

YOKOGAWA - DIGITAL LUX METERS 51000 SERIES

• Wide measurement range, high accuracy
• Spectral response characteristics for visible range
• Good oblique incident light characteristics
• USB communication and USB power supply
• Recorder output

 

YOKOGAWA - WT500 MID-RANGE POWER ANALYZER

• Current range: 0.5 to 40 A
• Voltage range: 15 to 1000 V
• Basic Power Accuracy: 0.1%
• frequency range: DC 0.5 Hz to 100 kHz

 

YOKOGAWA - SL1000 HIGH-SPEED DATA ACQUISITION UNIT

• Fast Acquisition
• Fast Transfer and Storage
• Easy to use
• Can operate "Standalone"

 

YOKOGAWA - DLM2000 MIXED SIGNAL OSCILLOSCOPES

• Lineup includes 200 MHz, 350 MHz, 500 MHz bandwidth models
• Lightweight and compact
• Large 8.4-inch LCD display
• Long memory: Up to 250 M points (with /M3 option)
• High speed sampling: Up to 2.5 GS/s (1.25 GS/s with 4 ch)

 

YOKOGAWA AQ6150 SERIES OPTICAL WAVELENGTH METER

• High wavelength accuracy of ±0.3pm
• Cope with modulated light and optical filter measurement
• Simultaneous measurement of up to 1024 wavelengths
• Increase throughput with high speed measurement