YOKOGAWA Multifunction Calibrator CA150 (Handheld)

Code: YOKOGAWA CA150


 

Datasheet PDF, 1.48 Mb
 

Description

The CA150 Handy Calibrator is a comprehensive source and measure instrument for your calibration and equipment checking needs at maintenance sites. The CA150 can simultaneously source and measure voltage, current, resistance, Thermocouple, RTD, and Pulse signals.

 

Features:

  • Power Supply
    • 6 AA size alkaline batteries
    • AC adapter (sold separately)
    • AC adapter specification: 100 to 240 VAC, 50/60 Hz, 1.4 A
    • Dedicated NiMH battery (sold separately)
    • OUTPUT: 12 VDC, 3 A
  • Auto power-off
    • Approx. 10 minutes; it can be canceled by setting.
  • Operating Temperature/Humidity Range
    • 0 to 40°C, 20 to 80 % RH (no condensation)
  • Storage Temperature Range
    • -20 to 60°C 90%RH or less (no condensation)
  • External Dimensions
    • 251 x 124 x 70 mm
  • Conforming Standards Safety
    • Safety EN61010-1
    • EMC EN 61326 Class B;EN 55011 Class B Group1
    • EN 61000-3-2; EN 61000-3-3, EN61326
 

More products YOKOGAWA

YOKOGAWA - AQ2200-651 SG MODULE

• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz
• Synchronize with external equipment: 10MHz reference Input/Output

 

YOKOGAWA MULTIFUNCTION CALIBRATOR CA71 CA51

• Autostep function
• Changes the output value in step form based on the setting from the divided output (n/m) function. Changes can be sourced automatically every 10% or 25%.
• Online communication (CA71 only) RS-232C-compliant optically isolated interface
• Sweep function
• Linearly increases or decrease the output. The increasing/decreasing time can be set to either 16 or 32 seconds.
• Memory function
• Source values and measurements forming individual value sets can be saved to or read from the Handy Calibrator's internal memory (maximum 50 value sets).
• Temperature monitor function

 

YOKOGAWA 2558A AC VOLTAGE CURRENT STANDARD

• Output Divider
• Direct Readout of the Deviation
• Digital Display of Output
• Common Current Output Terminals
• High Accuracy
• High Stability

 

YOKOGAWA -LAMP-ON TESTER CL155 (AC, TRUE RMS, 2000A)

• AC current measurement with current ranges up to 2000A
• AC/DC voltage and resistance measurements
• True RMS display
• 54mm in diameter of measurable conductor
• DC output function
• Data hold function

 

YOKOGAWA - DIGITAL MANOMETERS MT210 MT210F

• ±0.01%, with a maximum allowable input of 500 kPa (130 kPa-range model)
• Offering low differential pressure of 1 kPa to a high gauge pressure of 3000 kPa
• Normal speed, medium speed, and high speed (MT210F series)

 

YOKOGAWA CLAMP-ON POWER METER CW10 (SINGLE-PHASE)

• AC / DC Power up to 600 kW, AC / DC Voltage max. 1000 V, AC / DC Current max. 600 A
• True RMS for AC .
• Harmonics 1st to 25th order
• Power fluctuation using the ACA Inrush and Peak hold functions.
• Frequency, Resistance, Continuity, Diode check, Power factor.

 

YOKOGAWA FG400 ISOLATED ARBITRARY/FUNCTION GENERATOR

• Frequency range: Sine wave 0.01 µHz to 30 MHz
• Amplitude resolution: 16 bits
• Sampling rate: 120 MS/s
• Output: 0 to 20 Volts, peak-to-peak

 

YOKOGAWA - PX8000 PRECISION POWER SCOPE

• Provides simultaneous voltage and current multiplication to give real-time power sampling.
• Trend measurements between waveforms can be calculated by mathematical functions (up to four million points).
• Supports the capture of power parameters over specific periods of time through the definition of start and stop "cursors".
• An always-active History function automatically records up to 1,000 historical waveforms.

 

YOKOGAWA DIGITAL MULTIMETER TY720

• True RMS measurement
• New Functions for Electronic and Industrial Use
• Simultaneous measurement and display of DC and AC
• Switchable RMS/MEAN detection

 

YOKOGAWA GS610 SOURCE MEASURE UNIT

• Source and sink operation up to 110 V/3.2 A (four-quadrant operation)
• Basic accuracy: ±0.02% (DC voltage generation)
• Sweep output at up to 100-µ intervals
• Comes with abundant sweep patterns (linear, logarithmic, and arbitrary)
• Stores up to 65535 points of source measure data in the internal memory