YOKOGAWA AQ6374 Wide Range Optical Spectrum Analyzer 350 - 1750 nm

Code: YOKOGAWA AQ6374 Wide Range Optical Spectrum Analyzer 350 – 1750 nm


 

Datasheet PDF, 4.95 Mb
 

Description

The AQ6374 Wide Range Optical Spectrum Analyzer covers wavelengths from 350 to 1750 nm including visible lights (380 to 780 nm) and the telecommunication wavelengths.

 

World-Class Optical Performance

  • Wavelength range: 350 to 1750nm
  • High wavelength accuracy: ±0.05nm
  • High wavelength resolution: 0.05 to 10 nm
  • Wide dynamic range: 60dB (peak ±1.0nm)
  • Wide level range: +20 to -80dBm
  • Fast measurement: 0.5 sec. (100nm span)

 

Wavelength Resolution Settings:

There are 8 wavelength resolution settings: 0.05 to 10 nm
to enable the user to choose the best value according to the
device/system under test.

 

Measurable Level Range:

The wide measurable level range is from-80 to +20 dBm. This is suitable to measure high power as well as low power sources used in different fields of application.

 

Wavelength accuracy:

The ±0.05 nm wavelength accuracy can be maintained by the calibration using the built-in reference light source or an external light source including HeNe laser and Argon light source.

 

Fast measurement:

The instrument takes only 0.5 s for 100 nm span (with sensitivity set to NORM_AUTO).

 

Number of sampling: 100001

The number of wavelength samples has been doubled. One sweep can measure a wider wavelength range at high resolution.

 

Mouse and keyboard operation

More than 30 years of feedback from users have enabled intuitive and easy-to-use front panel operation. Mouse functionality provides ease of use for navigation and the keyboard helps to enter numbers and file names.

 

Trace zooming

  • Change display conditions, such as center wavelength and span, by clicking and dragging the mouse.
  • Enlarge your area of interest instantly and move it at will.
No need for another measurement to modify the display conditions
 

More products YOKOGAWA

YOKOGAWA - SL1000 HIGH-SPEED DATA ACQUISITION UNIT

• Fast Acquisition
• Fast Transfer and Storage
• Easy to use
• Can operate "Standalone"

 

YOKOGAWA DIGITAL RESISTANCE METER 7556

• Wide operating rangeability (1 Ohm range to 100 M Ohm range)
• Full remote controlability via the standard RS232C serial, or optional GP-IB interfaces
• Software based calibration
• Printer output of measurement, and statistical analysis results

 

YOKOGAWA 2553A PRECISION DC CALIBRATOR

• Digital Display of Output
• High Basic Accuracy
• High Stability and Low Noise
• High Resolution

 

YOKOGAWA DIGITAL INSULATION TESTER MY40

• 3 1/2-digit LCD;
• For each rating, you can save as many as 20 measurements at desired memory address numbers.
• Four AA (R6P) batteries the tester retains the measured resistance for approximately 5 seconds after the MEAS switch is turned off.

 

YOKOGAWA AQ4280 SERIES PORTABLE LIGHT SOURCE

• - SC, FC or other connector adapter
• (Removable for convenient access for cleaning)
• AQ4280 A/B/C : FC/PC, SC/PC, ST/PC
• - Rubber protector to prevent damage when dropped
• - Carrying pouch to house unit and connector adapters

 

YOKOGAWA - DLM4000 MIXED SIGNAL OSCILLOSCOPES

• DLM4038 350MHz
• DLM4058 500MHz
• (Standard) 8 analog channels or 7 analog channels + 8 bit logic
• (/L16 option) 8 analog channels + 16 bit logic or 7 analog channels + 24 bit logic
• Motor control & inverter circuit development
• Reliable triggering
• Best in Class Deep Memory & Architecture
• Two fully independent zoom windows

 

YOKOGAWA - AQ2200-651 SG MODULE

• Switchable two clock ranges: 620.0 to 720.0MHz, 155.0 to 180.0MHz
• Synchronize with external equipment: 10MHz reference Input/Output

 

YOKOGAWA AQ6360 TELECOM PRODUCTION OPTICAL SPECTRUM ANALYZER 1200 - 1650 NM

• Wavelength range: 1200 to 1650 nm
• Wavelength resolution: 0.1 to 2 nm
• High wavelength accuracy: ±0.02 nm
• High dynamic range: 55 dB
• Wide measurement range: +20 to -80 dBm

 

YOKOGAWA LS3300 AC POWER CALIBRATOR

• High Accuracy
• Phase Accuracy
• High Stability
• Wide generation range
• Single to three phase power calibration

 

YOKOGAWA - PNEUMATIC PRESSURE STANDARD MC100

• Low temperature coefficient Zero point: ±0.003% of full scale/°C Span: ±0.002% of full scale/°C
• Divided output function with as many as 20 steps
• Auto-step output function
• Sweep output function